• Title/Summary/Keyword: 단일 조사방식

Search Result 197, Processing Time 0.039 seconds

The Effect of External Radiation Therapy for Intracrania1 Arteriovenous Malformation - Conventional Radiation Therapy vs Stereotactic Radiosurgery - (뇌동정맥성 기형의 외부방사선 치료 효과)

  • Kim In Ah;Jang Hong Suk;You Mi Ryung;Yoon Sei Chul;Kim Moon Chan;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 1991
  • From February 1987 through July 1990, the seventeen cases of inoperable intracranial arteriovenous malformation (AVM) were treated using 6 MV linear accelerator at the Division of Therapautic Radiology, Kang Nam 51. Mary's Hospital. Of seventeen cases, fourteen were male and three were female. Ages ranged from 10 to 51 years (median age of 25 years). The main symtoms were headache, epilepsy and hemiparesis in decreasing order of frequency. The middle cerebral artery is the most common origin of the feeding vessel $(41.2\%)$. Four were treated by conventionally fractionated radiation therapy (CRT, thirteen were treated by stereotactic radiosurgery (RS). duration or follow-up in CRT and RS group were 4 to 43 months (median 33 months) and 3 to 12 months (median 13 months), respectively. When the response was assessed by radiologic follow-up study, two of four CRT group showed minimal response. Of thirteen cases of RS group, two $(15.4\%)$ showed complete response, five $(38\%)$ partial response, two $(15.4\%)$ minimal response and four $(30.7\%)$ no response by the same assessment. There was no statistical significance in terms of follow-up period (p=0.22), size of lesion (p=0.82) and treated dose (p=0.05). Further accumulation of experience is recommended with proper case selection and sufficient follow-up period.

  • PDF

Cyberspace and survey research: The methodological implications and issues of online survey research (사이버공간과 사회조사:온라인 사회조사의 쟁점과 과제)

  • 조동기
    • Survey Research
    • /
    • v.1 no.1
    • /
    • pp.73-108
    • /
    • 2000
  • This study investigates methodological implications of cyberspace and information technology for online survey research Online survey method provides useful methodological tools for collecting empirical data for the study of cyberspace, In terms of sampling frame , selection method, and questionnaire from four major types of the online survey research can be found: member survey visitor survey e-mail survey and the electronic survey. Online survey research with sample design(population specification error. sampling frame error, selection error) measurement (measurement instrument bias system-related processing error, nonrespone, and response bias) and research ethics (privacy and netiquette) pose important methodological issues for the survey. The realization of the technological possibilities of online survey will be possible only through a right consideration of these issues.

  • PDF

The Review of Saturn V 1st Stage (S-IC) Propulsion System (Saturn V 발사체 1단(S-IC) 추진기관 시스템 연구)

  • Hong, Yonggi;Kim, Cheulwoong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • It had been almost a half century since Apollo Mission was ended. However, in these days, a lot of researches are being conducted for restoration and making improvements in technologies used in Saturn V rocket's development. This study reviews the first stage of Saturn V rocket(S-IC), from development history to technologies in various subsystems such as engine purge system, POGO suppression system, hydraulic and pneumatic control system, propellant dispersion system, telemetry system and retrorocket system. Understandings of S-IC stage's operation systems would be helpful in understanding of launch vehicle system and reduction of time and cost in future development process.

중소기업을 위한 TQC도입의 사고방식과 유사점(상)

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.1 s.85
    • /
    • pp.100-104
    • /
    • 1984
  • 중소기업에서도 TQC가 부움을 이루고 있다. 비교적 규모가 큰 $40\~$50명 이상이 기업에서는 물론 소규모의 하청공업에서도 모회사에서 TQC의 실행이 촉구되어 도입하고 있는 예가 적지 않다. 그러나 이같은 부움 속에서 TQC가 충분한 효과를 올리고 있는 예는 별로 많지 않은 것 같다. TQC라고는 해도 조사의 충실에서 그치거나, QC서어클은 이름뿐이고 활동을 하지않거나 하는 예가 적지 않다. 또한 이같은 실패예는 TQC에 대한 이해부족이나 단지 타사에서 실시하고 있으니까 우리 회사에서도 한다는 등의 안이한 도입의 결과에 기인하는 수가 많다. 따라서 여기서는 중소기업에서 TQC를 도입할 경우, 또는 이미 도입한 TQC의 활동을 활발하게 하는데 필요한 유사점에 대하여 설명하기로 한다. 또한 TQC(Total Quality Control)를 소집단활동을 축으로 하여 경영의 체질개선을 도모하는 전사적인 활동의 의미에서 사용한다.

  • PDF

EFFECT OF SOFT-START LIGHT CURING ON THE POLYMERIZATION AND THE CONTRACTION STRESS OF COMPOSITE RESIN (완속기시(Soft-start) 광조사 방식이 복합레진의 중합 및 수축응력에 미치는 효과)

  • Wee, You-Min;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.332-343
    • /
    • 2005
  • The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at $400\;mw/cm^2$, plasma arc light curing for 6 seconds at $1300\;mW/cm^2$ and LED light curing for 10 seconds at $7The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at . For the soft-start curing method ; 2 seconds light exposure at $650\;mW/cm^2$ followed by 3 seconds at $1300\;mW/cm^2$ and exponential increase with 5 seconds followed by 10 seconds at $700\;mW/cm^2$ were used. Contraction stress was measured using strain gauge method and Vickers hardness was measured 24 hours after polymerization at the top and bottom of specimens. Resin-acrylic interfaces were observed using a scanning electron microscope(SEM). The results of present study can be summarized as follows: 1. Contraction stresses at 10 min after polymerization were significantly reduced with the soft-start curing both in plasma and LED light sources(P<0.05). 2. Plasma light curing with soft-start resulted in not only the lowest contraction stress, but also the lowest hardness(P<0.05) 3. LED light curing with soft-start showed lower contraction stress than the one-step continuous halogen and LED light curing(P<0.05). 4. Microhardness of specimens cured by LED light with soft-start was equivalent to that of cured by the one-step continuous halogen and LED light(P>0.05). 5. Curing by LED light with soft-start and conventional halogen light resulted in better marginal sealing than plasma light and one-step LED light curing.

  • PDF

Analysis of Soil Moisture Monitoring at a Hillslope in Forested Watershed (산림유역 사면에서의 토양수분 시계열 관측 분석)

  • Jang, Eunse;Gwak, Yong Seok;Lee, Jung Hun;Lee, Yeun Gil;Jung, Sung Won;Kim, Sang Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.490-490
    • /
    • 2015
  • 산림 사면에서의 토양층 수문반응은 물순환을 이해하는데 중요하다. 본 연구에서는 토양수분자료를 이용하여 토양수분의 계절적, 공간적 변화를 분석하였다. 연구대상지역은 경기도 파주시 적성면 설마리의 설마천 유역 내에 위치한 범륜사사면과 충청북도 음성군의 청미천 유역내의 수레의산사면이다. 정밀측량을 통해 획득한 수치고도모형(Digital Elevation Model, DEM)을 이용하여 관측지점들을 각각 선정하였다. 대상사면에 토양층별 토양수분의 분포변화를 분석하기 위해 각 지점별 10, 30, 60cm에서 토양수분량 측정시스템(Time Domain Reflectometry, TDR)방식의 토양수분측정장비(miniTRASE)를 설치하여 2시간 간격으로 2014년 3월부터 12월까지 토양수분을 측정하였다. 각 지점별 사면에서 획득된 토양수분 시계열자료는 토양수분의 시공간적 분포특성을 파악하기 위해 지점별 토양수분량의 통계분석(평균, 표준편차, 변동계수)를 수행하였다. 설마천유역의 범륜사사면에서는 2014년도에 특히 강우량이 적어 토양수분의 평균과 표준편차의 월별 변화에서는 기저토양수분 값을 주로 유지하고 강우에 대한 변동성이 크지 않은 것으로 나타났고, 청미천유역의 수레의산 사면에서는 시간적 토양수분변화는 계절적 강우분포 패턴에 따라 반응이 나타났다. 청미천유역의 토양수분자료를 이용하여 토양수분의 계절적, 공간적 변화를 분석한 결과 지표근처 토양층(10, 30cm)와 저층(60cm)에서의 공간적 변화특성이 다르게 나타났다. 이는 저층(60cm)에서의 지표하 흐름, 기반암 존재의 영향차이에 의한 것으로 판단되고, 사면의 위치에 따라 토양수분의 안정화 정도가 다른 것을 확인할 수 있다.

  • PDF

A Study on the Interevent Time Definition(IETD) depending on the Population of Rainfall Data in Busan Metropolitan City (부산광역시 강우자료의 모집단 구분에 따른 무강우 지속시간(IETD) 분석 연구)

  • Baek, Jongseok;Cho, Hyoseob;Kim, Hyungsan;Kim, Jaemoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.416-416
    • /
    • 2022
  • RCP(Representative concentrate pathways) 기후변화 시나리오에서는 2100년까지 연강 강수량과 강우지속시간이 지속적으로 증가할 것으로 예측하고 있다. 이에 도시지역의 하천 범람 및 내수 침수 예방을 위해 방재성늑목표의 상향조정과 방재 인프라의 설계년수 재조정 등에 대한 논의가 진행되고 있다. 하지만 수재해 예방을 위한 강우설계기준에서는 무강우 지속시간의 설정을 확보할 수 있는 최대 규모의 모집단을 통해 산정하는 방식으로 제시되고 있어 최근 기후변화로 인한 강우특성의 변화가 반영되기에 어려움이 있다. 본 연구에서는 부산광역시 강우자료의 모집단을 10년, 20년, 30년으로 구분하여 자기상관계수(Autocorrelation coefficient, AC) 분석, 변동계수(Coefficient of variation, CV) 분석, 연평균 강우사상 발생 개수(Average annual number of rainfall event, NRE) 분석 방법을 적용하여 비교 분석을 수행하였다. 그 결과, 자기상관계수 분석 방법과 변동계수 분석 방법에서는 모집단의 규모가 클수록 튀는 자료를 상쇄하여 안정적인 결과를 나타내는 반면, 연평균 강우사상 발생 개수를 확인 하였을 때는 대상기간에 큰 영향을 받지 않는 것으로 확인되었다. 또한, 모집단의 규모가 클수록 무강우 지속시간이 길어지는 것으로 분석되어 기후변화로 인한 최근의 강우특성을 반영하기 위해서는 모집단의 규모를 크게 잡는 것이 효과적이지 않을 수 있다는 점을 확인하였다. 이는 강우자료 분석 시 분석방법 및 모집단의 규모를 달리하여 무강우 지속시간을 산정해보고, 설계 목적에 따라 적정한 의사결정이 필요함을 시사한다.

  • PDF

The Survey of Parallel Programming Techniques for Developing Optimized Software in Multi-core System (멀티코어 시스템에서 최적화된 소프트웨어 개발을 위한 병렬처리 프로그래밍 기법 조사)

  • Lee, Ki-Hong;Kim, Jee-Hong;Eom, Young-Ik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.36-38
    • /
    • 2012
  • 이제 멀티코어 CPU가 보편화 되었지만 대다수의 프로그래밍 언어가 단일 코어를 대상으로 발전되었기 때문에 병렬화에 어려움이 있다. 이를 해결하고자 병렬처리 기법들이 연구되고 있지만 오히려 개발자는 여러 기법들 사이에서 혼란스러울 수 있다. 본 논문에서는 개발자들이 처한 상황에서 적절한 기법을 선택하는데 도움이 되고자 주요 병렬처리 기법인 OpenMP, Threading Building Blocks, Cilk Plus, Parallel Patterns Library를 비교 및 평가하였다. 각 기법마다 지원 기능, 지원 방식, 스케줄링 기법 등 개발자가 프로그램을 개발함에 있어 고려해야 할 특징들이 서로 다르고 각기 장단점이 존재한다. 따라서 병렬처리 기법을 선택하고 구현함에 있어 특정한 하나의 기법에 의존하는 것보다는 여러 기법들의 특성을 파악하여 상황에 맞는 기법을 선택한다면 보다 효율적이면서도 쉽게 병렬처리를 구현할 수 있다.

대기압 멀티 플라즈마 소스제작 및 방전 특성에 관한 연구

  • Jo, Tae-Hun;Yun, Myeong-Su;Jo, Lee-Hyeon;Kim, Dong-Hae;Jeon, Bu-Il;Choe, Eun-Ha;Jo, Gwang-Seop;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.275-275
    • /
    • 2012
  • 바이오메디칼 연구에 있어서 최근 플라즈마의 사용이 급격하게 늘어나고 있다. 세포나 세균에 플라즈마를 조사하여 이에 대한 반응성 연구와 의료용 살균기 등 여러 방면에서 필요로 하고 있다. 현재 주로 단일 플라즈마 소스를 이용한 실험이 진행되어가고 있다. 그러나 이러한 방식은 다양한 실험을 하기에는 시간이 다소 많이 걸리는 단점이 있다. 이에 다양하고 좀 더 정확한 연구를 위한 균일하게 방사되는 대기압 멀티 플라즈마 소스가 필요하다. 대기압 멀티플라즈마 소스는 각각 발생하는 플라즈마가 동일한 밀도 및 전자온도를 유지할 수 있도록 하는 것이 쉽지 않다. 이와 같이 상황에 맞는 소스를 제작하는 것도 중요하다. 본 연구에서는 24-well tissue culture testplate에 맞는 4개의 대기압 플라즈마 제트가 발생하는 소스를 목표로 하였다. 균일한 플라즈마가 발생할 수 있도록 시뮬레이션을 통하여 멀티 플라즈마 소스를 개발 및 제작하였다. 이에 대한 플라즈마 분석과 기초실험을 진행하여 재현성 테스트를 하였다.

  • PDF

A Study on the Anchorage Local Stress characteristics of Precast of Precast Prestressed Concrete Beams (프리캐스트 프리스트레스트 콘크리트 부재의 정착부 국부응력 특성에 관한 실험연구)

  • 오병환;임동환;양인환;박상현;장석훈;유승운;김종한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.224-227
    • /
    • 1992
  • 세그멘탈 교량에 포스트 텐셔닝 힘을 도입할 때 발생하는 가장 큰 문제는 균열의 발생이다. 이러한 균열은 실제 구조물의 강도감소 뿐 아니라, 이 균열은 염분 및 수분 침투의 통로가 되어, 부식 및 동결손상의 주원인이 되어 구조안전도에 큰 문제를 유발한다. 본 연구는 국부 집중 하중을 받는 프리스트레스 정착부의 응력분포 특성을 규명하고, 국부집중응력으로 인한 균열 발생 요인을 규명하여, 균열발생방지방안 및 그 대책을 강구함에 그 근본 목적이 있다. 이를 위하여 텐던에 대한 형상, 국부보강방식, 단일 및 복수텐던의 영향, 구조보강 철근량에 따른 콘크리트 내부 변형도 및 균열양상을 도출하기 위해, 부재를 제작하여 실험을 실시하여 균열의 양상 및 균열발생원인을 조사하고, 그 구체적 보강방안을 찾고자 한다.

  • PDF