• Title/Summary/Keyword: 단일굴곡

Search Result 34, Processing Time 0.028 seconds

Evaluating Distribution Trends of Classification Accuracy by Triangular Training Operator in SAR/VIR FCC : A Case Study of Songkhla Lake Basin in Thailand (SAR/VIR FCC에서 삼각 트레이닝 도구에 의한 분류정확도 분포추세 평가: 태국의 송클라 호수 유역을 사례로)

  • Jung Sup Um
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.3
    • /
    • pp.375-388
    • /
    • 2003
  • This study mainly focuses on evaluating how the triangular training operator could improve classification accuracy in SAR(Synthetic Aperture Radar) and VIR FCC(Visible Infra-red, False Colour Composite). The techniques for the determination of the most informative SAR/VIR combinations in the triangular space diagram, as developed tv the author of the paper, are given and the results obtained are presented. The SAR alone, VIR alone and SAR/VIR FCC classification showed trends for gradual improvement of accuracy. Accuracy distribution pattern for individual classes could be explained closely related to SAR/VIR signature components in the process of the triangular synergistic training. Due to contribution of SAR signature in training samples, it was possible to isolate major terrain features such as cloud cover area and roughness target with acceptable spatial precision. It is anticipated that this research output could be used as a valuable reference for distribution trends of classification accuracy obtained by triangular channel space based training in synergistic application.

Cytological Changes Associated with the Exposure of Escherichia coli to Several Disinfectants: An Ultrastructural Study (수종(數種) 항균제(抗菌劑) 처리(處理)에 의(依)한 Escherichia coli의 미세구조(微細構造) 변화(變化))

  • Deung, Young-Kun;Koh, Choon-Myung;Kim, Sung-Kwang
    • The Journal of the Korean Society for Microbiology
    • /
    • v.11 no.1
    • /
    • pp.1-11
    • /
    • 1976
  • An electron microscopic study has been made of the effects of change of cell structure of Escherichia coli treated with several disinfectants. The alterations observed as follows: 1. Nucleoid, cytoplasm which contain ribosomes and cell wall appeared to be composed of a parallel triple. layered membrane can observed in control Escherichia coli. 2. The nuclear material was no longer demonstrable in its normal sites. The cytoplasm lost its granularity, became homogeneous and disruption of cell wall were observed by the treatment with 70% ethyl alcohol and 3% $H_2O_2$. 3. Aggregation of ribosomes and condensation of nuclear material were also observed by the treatment of 5% lysol solution and 1% dodecyl-diamino-ethyl-glycin-hydrochloride. 4. In autoclaved group, the each layer of cell wall was separated and destroyed in some sites where cytoplasm was extracted.

  • PDF

Diagnosis & Surgical Treatment of Neurilemmoma (신경초종의 진단과 수술적 치료)

  • Suh, Jeung-Tak;Park, Byung-Guk;Yoo, Chong-Il
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.44-50
    • /
    • 1999
  • Neurilemmoma is a benign encapsulated nerve sheath tumor originated from peripheral nerve. Previously its preoperative diagnosis had mainly depended on the history, physical examination, electrodiagnostic test, ultrasonography, bone scan. But only with these diagnostic modalities, exact preoperative diagnosis was nearly impossible. Therefore operation was performed under the impression of lipoma or just simple soft tissue tumor. Recently, the advent of magnetic resonance imaging(MRI) has made it easier to diagnose neurilemoma before surgery. MRI also helps to determine the extent of lesion and operative procedures. We performed marginal excision in 24 cases, evaluated those cases with respect to the sex, age, location, chief complaint, duration of illness, preoperative diagnosis, involved nerve, imaging studies, size of mass, complication, duration of follow-up and report with review of the literature.

  • PDF

EDWARDS SYNDROME : REPORT OF A CASE (에드워드 증후군 환아의 증례보고)

  • Park, Ji-Eun;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.319-323
    • /
    • 2008
  • Edward's syndrome is a genetic disorder of 18th chromosomal trisomy. Main clinical features of this syndrome include systemic conditions, such as mental retardation, growth retardation, dyspnea, congenital heart disease, and orthopedic disorders, such as flexion deformity and rocker-bottom feet. The characteristics of fetal abnormality are hydramnios, small placenta, common umbilical artery. Infants with Edward's syndrome have very low survival rate. Almost half of them die during fetal stage. Fifty percent of them survive 2 months, and 5 to 10 percent of them survive about 1 year. A 3-year and 7 month old girl visited our dental hospital for the treatment of dental caries. Considering her systemic disease, low body weight, medical history of cardiac surgery, and difficulty in airway management, dental procedure was performed under general anesthesia. We report this case with review of literatures.

  • PDF

Generation of Triangular Mesh of Coronary Artery Using Mesh Merging (메쉬 병합을 통한 관상동맥의 삼각 표면 메쉬 모델 생성)

  • Jang, Yeonggul;Kim, Dong Hwan;Jeon, Byunghwan;Han, Dongjin;Shim, Hackjoon;Chang, Hyuk-jae
    • Journal of KIISE
    • /
    • v.43 no.4
    • /
    • pp.419-429
    • /
    • 2016
  • Generating a 3D surface model from coronary artery segmentation helps to not only improve the rendering efficiency but also the diagnostic accuracy by providing physiological informations such as fractional flow reserve using computational fluid dynamics (CFD). This paper proposes a method to generate a triangular surface mesh using vessel structure information acquired with coronary artery segmentation. The marching cube algorithm is a typical method for generating a triangular surface mesh from a segmentation result as bit mask. But it is difficult for methods based on marching cube algorithm to express the lumen of thin, small and winding vessels because the algorithm only works in a three-dimensional (3D) discrete space. The proposed method generates a more accurate triangular surface mesh for each singular vessel using vessel centerlines, normal vectors and lumen diameters estimated during the process of coronary artery segmentation as the input. Then, the meshes that are overlapped due to branching are processed by mesh merging and merged into a coronary mesh.

Fine Structural Analysis of the Venom Apparatus in the Spider Araneus ventricosus (산왕거미 (Araneus ventricosus) 독 생성장치의 미세구조 분석)

  • Moon, Myung-Jin;Yu, Min-Hee
    • Applied Microscopy
    • /
    • v.37 no.2
    • /
    • pp.53-63
    • /
    • 2007
  • The culticular substructure of the venom apparatus in the orb-web spider Araneus ventricosus are studied with scanning electron microscopy. The apparatus is composed of chelicera and paired venom glands in the cephalothorax. Each chelicera consists of a basal segment and a movable fang that articulates with each other. The chelicera of this spider is labidognathous form that moves at right angles to the body axis, and has two segments similar to that of a folding jackknife. Each cylindrical fang has a specialized hinge joint which articulate with the cheliceral groove which contains numerous small protrusions. In addition, each side of cheliceral groove is covered with a total of 7 cuticular teeth in two rows which composed of 4 promarginal and 3 retromarginal teeth. It has been also observed that a single venom pore is always located toward the direction of retromarginal teeth, and surface cuticular pits are distributed on the cuticular depressive area of cheliceral groove.

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Determinants of Successful Percutaneous Transluminal Coronary Angioplasty (경피적 관상동맥 성형술의 성공율에 영향을 미치는 인자에 대한 고찰)

  • Choi, Kyo-Won;Kweon, Jun-Young;Kim, Young-Jin;Lee, Tae-Il;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seup;Lee, Hyun-Woo;Lee, Sam-Beom
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.230-239
    • /
    • 1994
  • In Order to evaluate determinants of successful percutaneous transluminal coronary angioplasty (PTCA), PTCA was performed for 172 coronary arterial lesions in 120 patients (89 male, 31 female) at Yeungnam university hospital from Sep. 1992 to Aug. 1993. The corinary artery luminal diameter at the site of the original stenosis was eveluated from end-diastolic frames of identical projections of the preangioplasty and immediate post angioplasty. The coronary luminal and balloon diameters were measured with using of computer measuring system. Overall success rate of 172 attempted lesions was 87.2%. Success rate of female patients was 93.5% and higher than those of male patients. According to the clinical diagnosis, success rate in stable angina was 93.7% and higher than those of post myocardial infarction angina, unstable angina and acute myocardial infarcrion. Success rate of American Heart Association type C lesion was 65.5% and lower those of type A (95.7%), type B (89.5%). There was signfifcantly difference in preangioplasty luminal stenosis, elastic recoil and length of lesion between successful PTCA group and failed PTCA group. Success rate of lesion location at a bend > $45^{\circ}$ and presence of intracoronary thrombus were lower than than those of other angiographic findings. In coclusion, primary angioplasty success was affected by specific angiographic factors. Stenosis severity, thrombus, lesion location at a bend > $45^{\circ}$, elastic recoil, and length of lesion were the principle of determinants of coronary angioplasty success rate.

  • PDF

The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry (치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구)

  • Lee, Jong-Hwa;Park, Chun-Man;Song, Jae-Sang;Lim, Si-Duk;Kim, Jae-Do;Kim, Byung-Sik;Hwang, In-Whan;Lee, Sung-Kuk
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.