• Title/Summary/Keyword: 단일광자방출단층촬영

Search Result 37, Processing Time 0.033 seconds

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

THE SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN DEVELOPMENTAL LANGUAGE DISORDERS (발달성언어장애아(發達性言語障碍兒)의 단일광자방출전산화단층촬영(單一光子防出電算化斷層撮影) 소견(所見)에 관한 연구)

  • Park, Jin-Seng;Cho, Soo-Churl;Lee, Myung-Chul
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.46-55
    • /
    • 1992
  • The pathophysiology of developmental language disorder is a highly controversial matter. In order to investigate the neural mechanisms involved in developmental language disorders, the authors studied three dimensional regional cerebral blood flow(rCBF) using Tc-99mH-MPAO in 42 children with developmental language disorders. The results are summarized as follows : 1) 61.9% (26/42) of this series revealed decreased perfusion in SPECT. 2) Regions of hypoperfusion were seen in cerebral cortex(47.6%, 20/42), thalamus(33.3%, 14/42), basal ganglia(11.9%, 5/42) and cerebellum(7.1%, 3/42). This study suggests that developmental language disorder could be due to specific functional impairment of the local brain regions which could not detected by conventional investigations such as brain CT or EEG.

  • PDF

Comparison of Circular vs Non-Circular Orbit Data Acquistion using Single Head Single Photon Emission Computed Tomography (SPECT) (단일검출기 단일광자방출 전산화단층촬영술에서 원형(Circular)과 비원형(Non-circular) 회전방식 자료획득(Data Acquisition)의 비교)

  • Sohn, Hyung-Sun;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.118-124
    • /
    • 1995
  • 단일광자방출전산화 단층촬영술을 이용한 영상정보를 효과적으로 얻기 위하여 고려되어야 할 사항으로는 1) 조준기(collimator)의 선택, 2) 기질(matrix)의 크기, 3) 회전각의 수 (number of angles), 4) 360도 또는 180도 획득(acquisition), 5) continuous 또는 step& shoot, 6) 원형 또는 비원형회전 등이 있다. 저자들은 비원형회전으로 검체와 검출기 사이의 거리를 단축시킴으로써 직선성, 균일성, 대조도, 해상력에 미치는 영향을 알아보기 위하여 원형회전 방법과 비교하여 다음과 같은 결과를 얻었다. (1) 비원형회전을 하여도 균일성(uniformity)과 직선성(linearlity)을 유지한다. (2) 균일성, 대조도(contrast), 해상력(resolution)들이 비원형 회전을 한 경우에 보다 더 개선되었다. (3) 영상 획득시간은 비원형회전인 경우에 더 소요되었다. (매스캔 당 10분) 따라서 검사자는 영상 화질의 개선효과와 상반되는 보정(calibration)과 설치(set-up)에 소요되는 시간(매스캔당 10분이상)을 비교하여 자료획득(data acquisition) 회전방법을 선택하여야한다.

  • PDF

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.

SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN TOURETTE'S AND CHRONIC MOTOR TIC DISORDER (뚜렛씨병과 만성틱장애의 단일광자방출전산화단층촬영 소견에 관한 연구)

  • Cho, Soo-Churl;Lee, Myung-Chul;Kim, Ja-Sung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.68-78
    • /
    • 1993
  • The pathophysiology and neural mechanism involved in Tourette's and chronic motor tic disorder are highly controversial. In order to investigate the functional abnormalities of brain. In Tourette's and chronic motor tic disorder, 42 children with Tourette's and chronic motor disorder underwent single photon emission computed tomography(SPECT) using Tc-99m-HM-PAO. The results are summarized as follows : 1) 31.0% (13/42) of this series revealed perfusion defect in cerebral cortex. 2) 4.8% (2/42) revealed perfusion defect in basal ganglia. 3) 4.8(2/42) revealed perfusion defect in thalamus. 4) 16.7%(7/42) showed perfusion defect in cerebellum. 5) The frequency of abnormal perfusion showed no significant difference between tic with and without attention deficit hyperactivity disorder. 6) The frequency of abnormal perfusion showed no significant difference between Tourette's and chronic motor tic disorder. These findings support the hypothesis of a possible involvement of brain dysfunction in the production of Tourette's and chronic motor tic disorder, and quantification of blood flow and co-registration with magnetic resonance imaging will increase the validity of this study.

  • PDF

A Study on the Quantification Error due to the Reconstruction Filters in Single Photon Emission Computed Tomography(SPECT) (단일광자방출 전산화단층촬영상에서 재구성 필터에 의한 정량화 오차에 관한 연구)

  • 곽철은;정준기
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.43-48
    • /
    • 1991
  • As the computerized methods and equipments In nuclear medicine imaging increases, quantitative information is needed on the single photon emission computed tomographic Images as well as on the conventional nuclear medicine images. In this paper, the authors investigated the effect of several clinician - friendly reconstrution filters on the resultant transverse slices of backprojected Profiles of radioisotope distribution from the Quantitative point of view, and reduced the filter parameters such as cutoff frequency and order of filter which are neces mary to minimize the quantification error using computer-generated phantoms.

  • PDF