An Experimental Study on the Thermal Characteristics of Ice Storage Tank - Focusing on the Adiabatic Effects of Ice Storage Tank - (직접접촉식 빙축열조의 전열특성에 관한 연구 - 빙축열조의 단열영향을 중심으로 -)

  • Lee, Chae-Moon;Park, Jung-Won;Cho, Nam-Chul;Park, Sang-Rok;Kim, Il-Gyoum;Kim, Dong-Chun;Kim, Young-Ki;Yim, Chang-Soon
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.75-89
    • /
    • 1997
  • In this paper, the operating thermal characterictics of liquid-ice was expeimentally investigated in an adiabatic and a non-adiabatic direct contact liquid-ice heat exchanger. Experiments were carried out varing inlet temperature, Ice Packing Factor, and the flow rate of heat transfer fluid. The higher inlet temperature and the more much inlet flow rate, thermal stratification in liquid-ice heat exchanger was established faster. In the case of adiabatic ice storage tank, temperature distribution was a little higher at all conditions than that of non-adiabatic one. The ratio of latent energy to total discharge energy($E_{\lambda}/E_[tot}$) was about 80%, and the discharge of latent heat energy was appeared rapidly as inlet temperature and flow rate were higher.

  • PDF

Joint Characteristics in Layered Rocks (층상 암석에서 절리의 특성 연구)

  • Chang, Tae-Woo
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.145-152
    • /
    • 2009
  • Joints are planar tensile opening-mode fractures whose relative motion, as the fracture propagates, is perpendicular to bedding plane and occur in a systematic manner to form a joint set. This paper discusses the mechanical control of joint propagation, the relationship between join spacing and layer thickness, the join saturation, the frequency distribution of join spacing, the joint density, the cross joint, and the development mechanism of joint from a lot of recent joint studies in sedimentary rocks.

Properties of quasi-noncombustible ultra-lightweight geopolymer (준불연 초경량 지오폴리머의 물성)

  • Kim, Yootaek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.3
    • /
    • pp.132-139
    • /
    • 2019
  • EPS (expanded polystyrene) is one of the most used building materials for insulation that is favored by its excellent heat insulation, economical efficiency and lightweight characteristics. However, EPS is vulnerable to the fire and producing large amount of toxic gases in case of fire. Therefore, ultra-lightweight geopolymer which can replace EPS is fabricated by using IGCC (integrated gasification combined cycle) fused slag and Si sludge as raw materials and the possibility of replacement on ultra-lightweight geopolymer for EPS as an insulation building material was evaluated in this study. Ultra-lightweight geopolymer can be fabricated with the pulverized IGCC fused slag having low carbon content and density, compressive strength, thermal conductivity were $0.064g/cm^3$, 0.04 MPa, and 0.072 W/mK, respectively. The thermal conductivity of ultra-lightweight geopolymer is 1.5~2.0 times higher than that of EPS suggested in the KS M 3808; however, the thermal conductivity value of geopolymer is meaningful and competitive to that of EPS in the market. Therefore, ultralightweight geopolymer can be applicable to the building material for thermal insulation purpose and have an enough possibility to replace EPS in the future because it is not only much safer than EPS in case of fire but also it can be fabricate by using waste materials from the industry.

Effects of Spraying Conditions on the Porosity and Hardness of Plasma Sprayed MgO Stabilized Zirconic Thermal Barrier Coatings (Plasma 용사된 MgO 안정화 지르코니아 단열피복의 기공도와 경도에 미치는 용사조건의 영향)

  • Park, Yeong-Gyu;Choe, Guk-Seon;Lee, Dong-Hui
    • Korean Journal of Materials Research
    • /
    • v.2 no.2
    • /
    • pp.85-94
    • /
    • 1992
  • The size, morphology and distribution of pores which affect on the physical properties of thermal barrier coatings were investigated to find the relationship with spraying parameters. The plasma-sprayed zirconia coatings contained numerous micropores as well as macropores which were appeared as spherical and irregular pores, and cracks. The pore formation process and its characteristics were varied with spraying distance. Porosity itself was varied with spraying parameters such as spray gun current, gas flow rate and the gas used(Ar or $N_2). The Porosity of coatings was ranged from 10 to 18% with the variation of spraying conditions. The relative hardness measured by the scratch test, showed strong dependence on the porosity of coatings rather than spraying parameters.

  • PDF

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

Interpretation of Deformation History and Paleostress Based on Fracture Analysis Exposed in a Trench (트렌치에서의 단열분석을 통해 도출한 단열발달사 및 고응력 해석: 울산 신암리의 예)

  • Gwon, Sehyeon;Kim, Young-Seog
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.33-49
    • /
    • 2016
  • The study area, located in Sinam-ri, Ulsan, in the southeastern part of the Korean Peninsula, is mainly composed of hornblende granite (ca. 65 Ma). Fracturing and reactivation of a fault striking ENE-WSW was strongly controlled by the intrusion of a mafic dyke (ca. 44 Ma), which behaves as a discontinuity in the mechanically homogeneous pluton, increasing the instability of the basement in this area. A geometric and kinematic study undertaken to interpret the faults and fractures was performed in a trench excavated almost perpendicular to the orientation of the dyke. The analysis of structural elements, such as dykes, veins, and faults, is used to infer the deformation history and to determine the paleostress orientations at the time of formation of the structures. The deformation history established based on this analysis is as follows: (1) NNE-SSW, E-W, ENE-WSW, and NE-SW trending fractures had already developed in the pluton before dyke intrusion; (2) felsic dykes intruded under conditions of σHmax oriented N-S and σHmin oriented E-W; (3) mafic dykes intruded under conditions of σHmax oriented E-W and σHmin oriented N-S; (4) dextral reactivation of the main fault associated with the development of hydrothermal quartz veins under conditions of σHmax oriented E-W and σHmin oriented N-S; (5) sinistral reactivation of the main fault and high-angle normal faults under conditions of σHmax oriented NE-SW and σHmin oriented NW-SE; and (6) dextral reactivation of the main fault and NE-SW low-angle reverse faults under conditions of σHmax oriented NW-SE and σHmin oriented NE-SW. These results are consistent with the tectonic history of the Pohang-Ulsan block in the southeastern part of the Korean Peninsula, and indicates the tectonic deformation of the southern area of the Ulsan fault bounded by Yangsan fault was analogous to that of the Pohang-Ulsan area from the Cenozoic. This work greatly aids the selection of sites for critical facilities to prevent potential earthquake hazards in this area.

Characteristics of the Hydraulic Conductivity of Carbonate Aquifers in Gangwon Province (강원도 탄산염지역 대수층의 수리전도도 특성)

  • Park, Young-Yun;Lee, Jin-Yong;Lim, Hong-Gyun;Park, Yu-Chul
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • We investigated the flow properties of groundwater in areas of carbonate rocks at Yeongwol and Jeongseon, Gangwon Province, based on measurements of hydraulic conductivity. Existing hydraulic conductivity data were compiled from 46 wells in the study area. These wells were sunk close to Golji stream and the Joyang and Dong rivers, which flow through the study area. The hydraulic conductivities range from 0.004 to 1.1 m/day, and show a gradually decreasing trend with decreasing well depth (y=-0.003x - 0.927, $r^2$=0.129). The study area was classified into zone A (< 0.1 m/day), zone B (0.1-1.0 m/day), and zone C (> 1 m/day) according to hydraulic conductivity. Zones A, B, and C make up 87% (n = 40), 11 % (n = 5), and 2% (n = 2) of the surface of the study area, respectively. Among the three zones, zone A contains few fractures whereas zone C contains many fractures. These results indicate that groundwater flow in carbonate regions is strongly influenced by the fracture network.

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Flow Characteristics of Cryogenic Oxidizer in Liquid Propellant Rocket Engine (액체로켓 엔진에서의 극저온 산화제의 유동 특성)

  • 조남경;정용갑;문일윤;한영민;이수용;정상권
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.4
    • /
    • pp.15-23
    • /
    • 2002
  • In most cryogenic liquid rocket engines, liquid oxygen manifold and injector are not thermally insulated from room temperature environment fur reducing system complexity and the weight. This feature of cryogenic liquid rocket engine results in the situation that cryogenic liquid oxygen flow is easy to be vaporized especially in the vicinity of the manifold and the injector wall. The research in this paper is focused on two-phase flow phenomena of liquid oxygen in rocket engine. Vapor fraction was estimated by comparing the measured two-phase flow pressure drop in engine manifold and the injector with ideal single phase pressure drop. Heat flux into cryogenic flow is estimated by measuring the wall temperature on the engine manifold to examine boiling characteristics. Suitable correlations for cryogenic two-phase flow were also reviewed to see their applicability. In addition, the effect of vapor generation in liquid rocket engine manifold and injector on engine performance and stability was considered.