• Title/Summary/Keyword: 단열막냉각효율

Search Result 12, Processing Time 0.03 seconds

Influence of Flame Holder on Film Cooling Effectiveness of Ramjet Combustor (화염안정기 형상이 램제트 연소실에서의 슬롯 막냉각 특성에 미치는 영향)

  • Lee, Keon-Woo;Song, J.;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.315-320
    • /
    • 2008
  • This experimental study has been conducted to investigate the effect of the flame holder on the multi-slot film cooling in the ramjet combustor. The turbulent wake which is generated by the flame holder on the entrance of the coolant flow path affects on the slot. Adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

  • PDF

Characteristics of the Shaped Hole Film Cooling in Gas Turbine (가스터빈에서 변형홀을 사용한 막냉각 특성 해석)

  • 이동호;김병기;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.7-7
    • /
    • 1998
  • 가스터빈 엔진의 효율 및 성능은 터빈입구온도에 크게 좌우되므로, 높은 열효율을 얻기 위하여 최근 가스터빈 엔진은 높은 입구온도(대략 1400-150$0^{\circ}C$)에서 작동되도록 설계되고 있다. 이는 요소재질의 열한계점을 훨씬 상회하며, 이와 같은 입구온도의 고온화 경향은 터빈요소에 대한 열부하를 증가시키고 있다. 따라서 극한의 작동조건하에서의 허용수명 및 안정성의 유지를 위해서 내부대류냉각, 충돌세트냉각과 더불어 막냉각기법이 많이 응용되고 있다. 막냉각기법은 연소기 벽면 혹은 터빈블레이드 표면의 작은 구멍들을 통해서 압축기의 공기를 분사하여 표면에 고온의 유체와 일종의 단열벽을 형성하여 표면을 보호하는 냉각방법이다. 지금까지는 주로 단면적이 일정한 막냉각홀에 대한 연구가 주가 되어왔으나, 이러한 막냉각홀을 이용하는 경우 많은 문제점이 발생한다.

  • PDF

Effect of Mainstream Turbulence Intensity on Film Cooling of Combustor (연소기 벽면 막냉각에 주유동의 난류강도가 미치는 영향)

  • Kim Young Bong;Rhee Dong Ho;Cho Hyung Hee;Hahm Hee-Cheol;Bae Ju Chan;Oh Min Geun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.132-136
    • /
    • 2004
  • Experimental study has been conducted to investigate effect of mainstream turbulence intensity on film cooling performance of staggered rows of rectangular holes in combustor. Temperature fields and adiabatic film cooling effectiveness under $10\%$ mainstream turbulence intensity are measured. The results of temperature fields show that overall values are decreased and thicker film of coolant is formed downstream of rows of holes for high mainstream turbulence intensity. The results of film cooling effectiveness show that the values around the holes are smaller than the case of the low mainstream turbulence intensity, however, the difference of film cooing performance is decreasedforthefurtherdownstream.

  • PDF

Influence of the Vertical Flame holder on Heat Transfer Characteristics of Ramjet Combustor (세로축 화염안정기 형상이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Yang, Kang-Mo;Lee, Keon-Woo;Song, Ji-Woon;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.305-309
    • /
    • 2008
  • This experimental study has been conducted to investigate the installation of the vertical flame holder shape in ramjet combustor, which affects on the film cooling effectiveness. All slot position, the film cooling effectiveness decreases because of the shear layer and high turbulence intensity between separated flows and coolant flows. When the flame holder is installed, film cooling effectiveness decreases abruptly on the beginning of the slot exit region due to the mixing effect. As the blowing rate increases, the film cooling effectiveness is increased for all cases due to the augmented momentum of injected coolant from the slot.

  • PDF

축소 노즐에서의 슬롯 막냉각 열전달 특성에 관한 연구

  • 조용일;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.33-33
    • /
    • 2000
  • 고온의 연소가스로부터 노즐 표면을 보호하기 위하여 슬롯을 통하여 냉각 유체를 분사하는 슬롯 막냉각에 대하여 연구하였다. 냉각효율 및 열전달 특성은 주유동과 2차 유동의 분사율에 따라 크게 달라지며, 형상변화 및 유동가속에 의해서도 냉각 효과의 변화를 가져오게 된다. 따라서 본 연구에서는 실험을 통하여 면적비가 16:1인 축소노즐에서 압축성 효과를 배제할 수 있는 유동속도 범위 내에서 분사율 변화(0.5 $\leq$ M $\leq$ 3.0)에 따른 슬롯 막냉각 열전달 특성을 고찰하고, 평판 슬롯 막냉각 경험식의 결과와 비교하였으며, 수치해석을 통하여 축소노즐과 원형관에서의 냉각효율 및 열전달 특성을 비교함으로서 이를 검증하였다. 축소노즐에서의 슬롯 막냉각 열전달 특성은 단열벽면조건을 형성하여 노즐 표면을 따라 설치된 열전대를 이용하여 측정하였다. 그 결과 상대적으로 낮은 분사율(M=0.5, 1.0)에서 분사율 증가에 따른 냉각효율의 증가가 크게 나타났으며, 분사율이 높아짐(M $\geq$ 2.0)에 따라 냉각효율의 증가폭이 점점 감소하고, 일정 분사율 이상에서는 냉각 효율의 증가가 크게 둔화되었다. 분사율이 낮을 경우 평판 슬롯 막냉각 경험식으로 주어진 결과보다 상류에서는 높으나 하류로 진행하면 비슷한 냉각효율을 보였고, 분사율이 높은 경우 평판보다 전 범위에서 약간 높은 냉각효율을 나타냈다. 수치해석 결과에서는 분사율이 낮을 경우 축소노즐의 냉각효율이 원형관에서의 냉각효율 보다 낮거나 비슷하게 나타났으며, 분사율이 높아짐에 따라 축소노즐에서의 냉각효율이 오히려 높아지는 것으로 나타났다.타내었다. 액체 제트의 속도는 처음에는 일정하게 유지되다가 운동량을 보존하기 위해 가스로부터 운동량을 받아 점차 가속되어지는 것으로 나타났다.본 규격은 키, 총장, 어깨길이, 등길이, 머리길이, 머리둘레, 진동둘레, 목둘레, 가슴둘레, 허리둘레, 배둘레, 엉덩이둘레, 앞품, 뒤품, drop치를 포함하고 있고, 각 규격에서 호칭간 치수 간격도 함께 제시하고 있다. 본 연구 결과에서 보듯, 현행 8규격의 무진복의 각 호칭간 적정 허용범위를 고려해 합리적인 치수체계를 정립한다면 치수에 대한 적합도가 상당히 증가할 뿐 아니라 생산비용도 상당히 감축할 것으로 생각된다.나타났다. 4) 호감적 서비스능력 차원에서 세 독립변수간에 유의한 3원 상호작용이 존재하는 것으로 나타나( $F_{2,228}$=15.62, P<.001) 20대에 적합한 의복 착용시( $F_{2,228}$=3.98, P<.05)와 60대에 적합한 의복 착용시( $F_{2,228}$=16.55, P<.001) 점포유형과 격식차림간에는 유의한 상호작용이 존재하는 것으로 나타났다. 5) 호감을 구성하는 세 요인들이 구매의도에 미치는 영향을 조사한 결과 호감적 인상차원은 29%(P<.001), 호감적 서비스능력차원은 6%(P<.001)의 구매의도를 설명해 주는 것으로 나타났다. 본 연구결과 노년 소비자에게 호감을 주는 판매원의 외모는 구매의도에 영향을 주어 실버의류산업의 이익증대와 밀접한 연관을 갖는 서비스품질의 중요한 요인으로 밝혀졌다.중요한 요인으로 밝혀졌다.로운 단백질 EPSPS가 다른 여러 식물에 이미 존재하고 있는 단백질로서 우리가 이미 이러

  • PDF

Heat Transfer Characteristics under Recirculation zone of Ramjet Combustor (재순환 영역이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Lee, Keon-Woo;Oh, Min-Keun;Ham, Hee-Chul;Hwang, Ki-Young;Cho, Hyung-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-17
    • /
    • 2007
  • This experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

A Study of Film Cooling of a Cylindrical Leading Edge with Shaped Injection Holes (냉각홀 형상 변화에 바른 원형봉 선단의 막냉각 특성 연구)

  • Kim, S.-M.;Kim, Youn J.;Cho, H.-H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.298-303
    • /
    • 2002
  • Dispersion of coolant jets in a film cooling flow field is the result of a highly complex interaction between the film cooling jets and the mainstream. In order to investigate the effect of blowing ratios on the film cooling of turbine blade, cylindrical body model was used. Mainstream Reynolds number based on the cylinder diameter was $7.1{\times}10^4$. The effect of coolant flow rates was studied for blowing ratios of 0.7, 0.9, 1.2 and 1.5, respectively. The temperature distribution of the cylindrical model surface is visualized by infrared thermography (IRT). Results show that the film-cooling performance could be significantly improved by the shaped injection holes. For higher blowing ratio, the spanwise-diffused injection holes are better due to the lower momentum flux away from the wall plane at the hole exit.

  • PDF

Film Cooling from Two Rows of Holes with Opposite Orientation Angles(I) -Configuration Effect- (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(I) -배열의 영향-)

  • Ahn, Joon;Jung, In-Sung;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1122-1130
    • /
    • 2001
  • Film cooling performance from two rows of holes with opposite orientation angles is evaluated in terms of heat flux ratio. The film cooling hole has a fixed inclination angle of 35°and orientation angle of 45°for the downstream row and -45°for the upstream row. Four film cooling hole arrangements including inline and staggered configurations are investigated. The blowing ratio studied was 1.0. Boundary layer temperature distributions are measured to investigate injectant behaviors and mixing characteristics. Detailed distributions of the adiabatic film cooling effectiveness and the heat transfer coefficient are measured using TLC(Thermochromic Liquid Crystal). For the inline configuration, there forms a downwash flow at the downstream hole exit to make the injectant well attach to the wall, which gives high adiabatic film cooling effectiveness and heat transfer coefficient. The evaluation of heat flux ratio shows that the inline configuration gives better film cooling performance with the help of the downwash flow at the downstream hole exits.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles(II) -Blowing Ratio Effect- (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성(II) -분사비의 영향-)

  • Ahn, Joon;Jung, In-Sung;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1131-1139
    • /
    • 2001
  • Experimental results are presented, which describe the effect of blowing ratio on film cooling from two rows of holes with opposite orientation angles. The inclination angle is fixed at 35°, and the orientation angles are set to be 45°for the downstream row, and -45°for the upstream row. The studied blowing ratios are 0.5, 1.0 and 2.0. The boundary layer temperature distributions are measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions are measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux is evaluated from the adiabatic film cooling effectiveness and heat transfer coefficient data. The results show that the investigated geometry provides improved film cooling performance at the high blowing ratios of 1.0 and 2.0.

Film Cooling from Two Rows of Holes with Opposite Orientation Angles: Blowing Ratio Effects (반대방향의 방향각을 갖는 2열 분사구조의 막냉각 특성 : 분사비의 영향)

  • Ahn, J.;Jung, I.S.;Lee, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.113-118
    • /
    • 2000
  • Experimental results describing the effects of blowing ratio on film cooling from two rows of holes with opposite orientation angles are presented. The inclination angle was fixed at $35^{\circ}$ and the orientation angles were set to be $45^{\circ}$ for downstream row. and $-45^{\circ}$ for upsream row. The studied blowing ratios were 0.5, 1.0 and 2.0. The boundary layer temperature distributions were measured using thermocouple at two downstream loundary layer temperature distributions were measured using thermocouple at two downstream locations. Detailed adiabatic film cooling effectiveness and heat transfer coefficient distributions were measured with TLC(Thermochromic Liquid Crystal). The adiabatic film cooling effectiveness and heat transfer coefficient distributions are discussed in connection with the injectant behaviors inferred from the boundary layer temperature distributions. Film cooling performance, represented by heat flux was calculated with the adiabatic film cooling effectiveness and heat transfer coefficient data.

  • PDF