• Title/Summary/Keyword: 단열기초

Search Result 129, Processing Time 0.024 seconds

A Study on the Basic Properties of Foam Glass Aggregate for the Application of Insulated Foundation (단열바닥기초 적용을 위한 발포유리 골재의 기초 특성 평가)

  • Sang-Heon, Kim;Soo-Young, Moon;Hyun-Soo, Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.420-427
    • /
    • 2022
  • The present study evaluated the physical, mechanical and thermal properties of the foam glass aggregate and insulation foundation with this, in order to promote the use of insulated foundations using domestically produced foamed glass aggregates. As a result of the evaluation, the compacted foam glass aggregate showed at the same level as overseas products in terms of unit volume mass, particle size and other characteristics, and a compressive strength of 40.6 N/cm2, which was superior to the existing organic insulation materials such as XPS. And the thermal conductivity of the foam glass aggregate was 0.84 W/mK, and the thermal transmittance of the specimen simulating the insulation foundation was 0.37 W/mK, so the thermal conductivity of the foam glass aggregate was estimated to be 0.80 W/mK. With these results, it was found that it is possible to use the insulation foundation with re-producted foam glass aggregate by crushing the waste from the process of producing foam glass products.

An Adiabatic Analysis on the Vuilleumier Refrigeration Cycle (Vuilleumier 냉동사이클에 대한 단열해석)

  • 유호선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1231-1237
    • /
    • 1989
  • 본 연구에서는 이러한 단열해석상의 문제점을 해결하기 위한 하나의 방식이 광방법으로서 적절한 가정을 도입하여 단열모델에 대한 해석적인 근사해를 시도하였다. 실제조건에 부합하면서도 간편하며 경제적인 해석방법의 확립은 VM 사이클로 작동되는 냉동기에 대한 최적설계의 중요한 기초가 될 것이다. 해석모델의 정립, 종속변수에 대한 근사해, 성능평가에 필요한 열역학적량들을 종속변수의 해석적 함수형태로 표시하는 과정을 내용에 포함한다.

Development of Temperature Control Technology for Massive Machine Foundations (기계기초 매스콘크리트의 균열제어를 위한 온도관리기법의 개발)

  • Huh, Taik-Nyung;Son, Young-Hyun;Lee, Suck-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.227-233
    • /
    • 2001
  • 최근 비약적인 경제발전에 힘입어 장대교량, 항만, 댐, 도로, 원자력 발전소 등과 같은 대규모 기간구조물의 건설이 증가하고 있으며, 구조물은 대형화 혹은 고강도화되는 추세에 있다. 특히, 전술한 구조물을 매스콘크리트로 가설하게 되면 초기재령시에 수화열로 인한 균열이 발생할 가능성이 매우 높기 때문에 효율적인 매스콘크리트의 개발과 매스콘크리트 구조물의 설계기술 및 시공방법이 중요한 연구대상으로 등장하게 된다. 본 논문에서는 가로 52.6m, 세로 14.4m, 높이 8.5m의 기계기초 매스콘크리트의 시공에 적합한 온도관리기법을 다음과 같은 단계로 제안하고자 한다. 먼저 온도상승요인을 최소화하는 콘크리트의 배합비를 산정한다. 산정된 콘크리트의 열특성을 측정하기 위해 단열온도실험을 수행하여 각종 열특성상수와 단열온도 상승곡선식을 도출한다. 이와 같은 열특성치를 콘크리트 구조체에 적용하여 열응력해석을 수행한다. 이와 같은 열응력해석을 통하여 구조물의 분할타설높이에 따라 온도균열이 발생하지 않는 콘크리트 내외부의 온도차를 결정한다. 이때 열응력해석에 범용 유한요소 프로그램인 Diana을 사용한다. 콘크리트의 타설은 현장조건과 타설시점을 최대로 고려하고 양생방법으로 콘크리트 내외부의 온도차를 최소화하기 위해 이중단열효과가 있는 거푸집과 가열장비을 사용한다. 또한 콘크리트의 온도관리를 위하여 구조물 내외부에 온도게이지를 매립하고 30분마다 계측을 수행하면서 콘크리트 내외부 온도차가 허용 해석범위를 유지하도록 한다. 양생기간은 7-10일 정도를 유지한다. 전술한 온도관리기법을 통하여 완공후 수평정밀도가 기초의 허용침하량으로 환산하여 $1{\mu}m$ 인 고정밀도의 기계기초는 완벽하게 시공되었다. 따라서 매스콘크리트의 온도균열을 제어할 수 있는 시공방법으로 제안한다. 또한 매스콘크리트의 내외부 온도차를 단열온도실험과 온도해석으로부터 정한 값이내로 제어하고 충분한 양생관리를 병행하면 수화열에 의한 콘크리트의 온도균열을 최소화할 수 있을 것으로 기대한다.

  • PDF

Quantification of Heterogenous Background Fractures in Bedrocks of Gyeongju LILW Disposal Site (경주 방폐장의 불균질 배경 단열의 정량화)

  • Cho, Hyunjin;Cheong, Jae-Yeol;Lim, Doo-hyun;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.463-474
    • /
    • 2017
  • Heterogeneous background fractures of granite and sedimentary rocks in Gyeongju LILW (low-intermediate level radioactive waste) facility area have been characterized quantitatively by analyzing fracture parameters (orientation, intensity, and size). Surface geological survey, electrical resistivity survey, and acoustic televiewer log data were used to characterize the heterogeneity of background fractures. Bootstrap method was applied to represent spatial anisotropy of variably oriented background fractures in the study area. As a result, the fracture intensity was correlated to the inverse distance from the faults weighted by nearest fault size and the mean value of electrical resistivity and the average volumetric fracture intensity ($P_{32}$) was estimated as $3.1m^2/m^3$. Size (or equivalent radius) of the background fractures ranged from 1.5 m to 86 m and followed to power-law distribution based on the fractal property of fracture size, using fractures measured on underground silos and identified surface faults.

Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation (동계 아파트 외표면 온도에 의한 단열성능 비교평가)

  • Park, Jung-Hun;Kim, Bong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.91-100
    • /
    • 2013
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. Furthermore, it is to predict the part of occurrence of the thermal bridge and condensation at the apartment building structure. On the other one hand, it is also to analyze the degree of thermal insulation performance according to the standards of thermal insulation and elapsed time, through the analysis by the workability of concrete.

An Experimental Study on the Fundamental and Adiabatic Temperature Rise Properties of High Volume Fly Ash Concrete (HVFA 콘크리트의 기초물성 및 단열온도상승 특성에 관한 실험적 연구)

  • Kim, Sung-Su;Choi, Se-Jin;Jeong, Yong;Lim, Keun-Chang;Park, Dae-Gyun;Cho, Yun-Gu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.309-310
    • /
    • 2010
  • In this study we investigated the properties of the fundamental and adiabatic temperature rise of the concrete using high volume fly-ash. For this, the fly ash was used to replace cement at replacement ratio of 40% and 50% by mass, and then the slump, air content, bleeding, compressive strength and adiabatic temperature rise test of concrete were performed.

  • PDF

Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance (준불연 외단열시스템의 역학적 특성에 관한 연구)

  • Choi, Ki-Sun;Ha, Soo-Kyung;Oh, Keun-Yeong;Park, Keum-Sung;Ryu, Hwa-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.507-518
    • /
    • 2021
  • The application of an adhesive calcium carbonate-based hybrid insulation board with quasi-combustibility in the external thermal insulation composite system(ETICS) ensures effective thermal performance and fire safety. This study aimed to conduct a mechanical test of the quasi-non-combustible hybrid insulation board as well as its constituent materials to obtain the basic data for the structural design of the adhesive ETICS. Test specimens were fabricated based on domestic and foreign test standards to examine and evaluate their tensile, compressive, flexural, and shear strengths. The strength characteristics of the quasi-non-combustible hybrid insulation board were identified from the test results, which verified that the minimum required physical properties suggested by the current KS M ISO 4898 were met. Furthermore, the quasi-non-combustible ETICS used in this study was found to be suitable for use as an external insulation system for walls unless subjected to continuous gravity load, such as a heavy exterior finish.

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

A Research on Air-tightness and Thermal performance of windows system classified by Windows type (에너지효율화를 위한 창호 유형별 기밀 및 단열성능에 관한 조사 연구)

  • Choi, Gyeong-Seok;Kang, Jae-Sik;Yang, Kwan-Seob;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.120-123
    • /
    • 2009
  • 건물에서 에너지손실이 큰 창호에 대해 최저소비효율기준 및 에너지소비효율 등급기준(안) 도입을 통해 지속가능한 고효율 창호의 보급 활성화 촉진과 관련 산업의 기술 및 산업력 향상을 적극적으로 유도할 필요가 있다. 이에 본 연구에서는 창호의 에너지 효율화를 위하여 고효율기자재(고기밀성 단열창호)로 인증받은 약 100여개 제품과 기타 제품에 대하여 창호 유형별 기밀 및 단열성능의 조사 분석을 통하여 창호 관련 제도 개정에 기초자료로 활용 에너지절약과 기후변화협약 관련 건물부문의 구체적 실천 대응방안으로 활용하고자 한다.

  • PDF

Effects of the Moisture on the Overall Heat Transfer Through Heat Insulators Opaque Envelopes (불투명 외피의 열관류에서 단열재의 습도영향)

  • Lee, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 1998
  • The heat conduction and the water vapour diffusion flow through heat insulators between hygroscopical moist building materials were measured by means of the plate method. It was found that the heat transport increases with a moisture motion occuring in the temperature drop. On his basis of simplified assumptions, the increase in the thermal conductivity was calculated from the rate of diffusion flow per unit area, which generally resulted in values inferior to the measured values. The Increase in the heat transport due to water vapour diffusion measured at a large-scale wall specimen was inferior to the one measured by means of the plate method by using a comparable arrangement of layers. The overall heat transfer caused by moisture motion is not a characteristic value of the material, but a property of the whole wall structure

  • PDF