공동주택용 온수난방 시스템의 에너지해석 및 제어특성 (The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses)

  • 장효환;안병천
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

광센서를 이용한 제상제어 방법에 대한 타당성 검토 (Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors)

  • 전창덕;김동선;이승준
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3389-3395
    • /
    • 2014
  • 제상제어 수단으로 사용하고 있는 일정 시간 제어방식, 온도차 제어방식 등은 종종 제상 오작동과 에너지 낭비를 가져오므로 좀 더 정확하게 제상을 제어할 수 있는 방법이 요구되고 있다. 수광부와 발광부로 구성된 광센서를 실외 열교환기 전방에 설치하여 서리의 유무에 따른 출력전압의 변화를 관찰함으로서 정확하게 제상제어를 할 수 있다. 본 연구에서는 기존의 일정시간 제상 방법을 사용하는 경우 나타나는 시스템 성능 및 특성 곡선을 광센서를 사용하여 재현가능한지 판단하기 위해 KS C 9306에 따른 난방 제상능력 시험조건(건구온도 $2^{\circ}C$/습구온도 $1^{\circ}C$)에서 실험을 수행하였다. 실험을 통해 측정한 난방능력, 소비전력, 열교환기 표면온도와 광센서 수광부 출력전압을 비교, 분석한 결과 제상 제어수단으로 광센서의 사용가능성을 확인하였다. 일정시간 제상방법을 통해 구한 제상 제어 단속 주기는 광센서를 통해 측정한 출력 전압의 단속 주기와 잘 일치하였다.