초고압 단로기 접점의 단락전류 통전성능 평가기술 개발 (Development of Evaluating Technology for the Capability of Carrying Short-Circuit Current at Electrical Contacts in EHV Disconnecting Switches)

  • 오연호;송기동;정진교
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.46-51
    • /
    • 2008
  • Extra-high voltage(EHV) disconnecting switch(DS) consists of the electrical contacts and mechanical parts which actuate the contacts. When the short-circuit condition occurs, a large amount of current flows through the electrical contact in disconnecting switches and this causes considerable temperature rise due to Joule heating. If the temperature rise is higher than the melting point of contact material, the DS contact becomes melting and cannot be usable anymore. For this reason, the analysis for capability of carrying short-circuit current in DS contacts must be performed at a design stage. Here, we proposed a numerical technique for evaluating the capability of carrying short-circuit current at electrical contacts in EHV DS. In this numerical approach, the mechanical and thermal analyses were simulated to check the capability of carrying short-circuit current. First, the applied pressure at contact parts was analyzed considering the mechanical properties, and then contact resistance was calculated by an empirical equation. Finally, thermal analysis was performed with resistance variation at electrical contacts. To verify these numerical results, the distributions of temperature in DS were experimentally measured and compared with each other. The results from experiments were agreed well with those from the proposed numerical simulations.

MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구 (Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices)

  • 심해섭;전태현
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.71-77
    • /
    • 2010
  • 뇌서지 보호는 오늘날 대부분의 전기전자기기에 있어 중요한 문제 중 하나이다. 그리고 뇌서지 보호를 위한 대다수 SPD의 가장 주요 부품으로 MOV가 사용된다. 본 논문에서는 다양한 타입의 MOV 기반 SPD를 조사하고 낮은 MLV특성의 부작용에 대하여 실험하였다. 실험결과로서 상대적으로 낮은 MLV특성은 실제 현장에서 발생 가능한 TOV 고장 상태하에서 더 큰 고장률로 나타날 수 있으며, 피보호기기보다 우선하여 소손될 수 있음을 알 수 있다. 결국 안전면에서 SPD는 높은 TOV내력과 신속한 단로기의 동작이 요구된다.

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (Fatten Analysis of Trouble Signal on DS for GIS using Neural Network)

  • 김종서;이은석;천종철
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.

도시철도 절연기기의 진단데이터 획득 기술 (Fault Diagnosis Technology of Power Supply Insulation System in Metro Substation)

  • 박영;정호성;김형철;오석용;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.266-266
    • /
    • 2009
  • 현재 도시철도 전력설비의 진단시스템은 각 설비별로 산재되어 있어 종합적 상태를 실시간으로 모니터링 할 수 있는 시스템 구축이 필요하다. 특히 전력설비 고장을 사전에 검출하고 최적의 수명을 예측하기 위해서 표준화되고 객관적인 상태 판단을 위한 시스템 도입이 필요하다. 또한 도시철도 변전소가 무인으로 운영됨에 따라 전력실비 자체의 온라인 상시감시 및 자기진단을 수행할 수 있는 다양한 시스템을 도입이 필요하다. 본 연구에서는 도시철도 주요 전력설비 인 도시철도용 (AC/DC) 변압기, 단로기, 차단기, 정류기, GIS에 설치되는 각종 센서, 센서에서의 데이터를 측정하는 이상검출장치에서의 데이터를 수집하는 데이터취득장치, 데이터취득장치와 서버를 연결하는 통신제어장치, 모니터링 프로그램과 수명예측 프로그램이 설치된 서버를 포함하여 각종 부가 장치를 포함하는 변전기기 수명예측을 위한 전체 시스템의 개발에 대하여 기술 하였다. 또한 무선기반의 고장진단 검측 시스템을 구현하고 데이터 획득 기술에 대하여 나타내었다.

  • PDF

저압차단기 규격동향 및 IEC SC17B, SC17D 활동에 관한 고찰 (Trends in standards of low voltage circuit breaker and activities of IEC SC17B, SC17D)

  • 이동준;노창일;정흥수;김선구;김원만;김선호;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.951-952
    • /
    • 2007
  • International Electrotechnical Commission (IEC)은 국제 규격을 제 개정하는 단체로서, 1906년에 설립된 조직이다. 2006년 말 기준으로 67개국의 회원 국가를 보유하고 있으며 총 5,613개의 규격을 제 개정하고 있다. IEC는 많은 수의 규격을 제 개정하기 위하여 100개의 Technical Committee (TC)와, 각 TC 산하에 Subcommittees(SC)를 두고 있다. SC는 다시 산하에 Working group(WG)을 두어 실제적으로 해당 국제규격의 제 개정은 바로 이 WG에서 작업을 하게 된다. 본 논문에서는 IEC TC17내의 SC17B와 SC17D의 구성, 현황 및 활동과 현재 진행되고 있는 저압차단기의 규격동향에 대하여 고찰하였다. IEC TC17은 차단기, 개폐기(스위치), 단로기, 버스관로 및 배전반등과 관련된 IEC 규격의 제 개정을 담당하고 있다. TC17 산하의 SC17B는 저압 차단기, SC17D는 저압배전반제품과 관련된 규격을 관리하고 있다. 한국은 SC17B와 SC 17D의 P-member(Participant)로서 투표권을 갖고 있으며, 한국전기연구원이 운영간사를 맡고 있다. 현재 국내기업체 전문가와 연구원들의 의견을 수렴하여 국가의견으로서 IEC에 제출하고 있지만 앞으로 더 많은 전문가들의 참여가 시급한 실정이다.