• Title/Summary/Keyword: 다중 펄스

Search Result 252, Processing Time 0.026 seconds

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Study on the Debonding Detection Techniques of Liner/Propellant Interface of Rocket Motor (추진기관의 라이너/추진제 미접착 검출 기법 연구)

  • Kim, Dong-Ryun;Ryoo, Baek-Neung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.40-47
    • /
    • 2008
  • It is known that the adhesive interface testing of the rocket motor using the ultrasonic wave is superior to the other testing methods about the ability to economical detect the defects. But, the signal analysis of the ultrasonic wave takes a lot of time and efforts because the time interval of the transmitted pulse and the received pulse is too short to separate the reflected signals due to the multi-layers of the rocket motor. The ultrasonic testing of rocket motor have only applied to the automatic system about extremely limited areas like the debond in adhesive interface between the motor case and the insulator. In this study the new technique to detect the debond between the liner and the propellant using the property of the resonance and the lamb waves instead of the existing ultrasonic testing was described.

The Analysis of the Effect of Narrowband Interference on UWB communication system (UWB(Ultra-Wide Bandwidth) 통신 시스템에서 협대역 간섭 잡음 해석)

  • 박장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1153-1160
    • /
    • 2003
  • In this paper, the performance of the UWB communication systems is analyzed in the presence of the Narrow Band Interference(NBI). UWB communication systems are modeled as using the Pulse Position Modulation(PPM). In this system, a Gaussian monocycle is used as the received pulses. The NBI is considered as a zero-mean random process with a constant spectral power density over its whole bandwidth. We obtain the mathematical expressions for describing the effect of the NBI on the UWB system. And it can be shown that the suppression of the effect of NBI on the UWB systems is available by adjusting the PPM related parameter.

Design of Ultrasound Dynamic Focusing Systems (초음파 다이나믹 집속 시스템의 설계)

  • 김진하;김청월
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 1984
  • The design formular of optical focusing systems cannot be applied to ultrasonic B scanners, which use broadband pulses instead of continuous wave. In this paper, a calculation method is studied for analyzing the propagation of ultrasonic broadband pulse excited by ultrasonic array transducers. Using the results, seveial design parameters such as the number of transducer elements, delay time, and the focal point are determined to obtain high resolution in the ultrasonic dynamic focusing system. A dynamic focusing system with low-noise switching characteristics; which attains lateral resolution of 2-3mm all along the axial direction up to 18 cm with a 3.5 MHz linear array transducer, was implemented.

  • PDF

Study on the Debonding Detection Techniques of Liner/Propellant Interface of Rocket Motor (추진기관의 라이너/추진제 미접착 검출 기법 연구)

  • Kim, Dong-Ryun;Ryoo, Baek-Neung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.55-59
    • /
    • 2007
  • It is known that the adhesive interface testing of the rocket motor which using the ultrasonic wave iS superior to the other testing methods about the economically detectable abiliη of the defects. But, the signal analysis of the ultrasonic wave takes too much time and effort that the time interval of the transmitted pulse and the received pulse is too short to be separated the reflected signals because the structure of the rocket motor is multi-layers. The ultrasonic testing of rocket motor have been only applied with automatic system about extremely limited area like the debond in adhesive interface between the motor case and insulator. In this study the new technique to detect the debond between the liner and the propellant using the property of the resonance and Lamb waves was described as comparing the existence ultrasonic testing.

  • PDF

Chaos system using PPM-DCSK modulation (PPM-DCSK 변조를 이용한 카오스 시스템)

  • Kim, Sung-Gon;Jang, Eun-Young
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.814-820
    • /
    • 2020
  • In the M-ary DCSK system up to now, as M increases, the distance between constellation signal points becomes closer and performance deteriorates. we propose a hybrid modulation scheme based on PPM and DCSK to improve the BER performance. one part of the bit is modulated by the PPM and the other part by DCSK. Thus, the information bearing signal is modulated simultaneously according to the selected pulse position of the PPM determined by the information bit and the additional information bit. The analytical BER performance of the proposed plan is derived and verified by simulation. The results show that the proposed scheme outperforms conventional M-DCSK, code index modulation DCSK and rectified code index DCSK in additional white Gaussian noise and multipath Rayleigh fading channels.

Characteristics of Al Doped ZnO Thin Film by Modulated Pulsed Power Magnetron Sputtering

  • Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.430-430
    • /
    • 2012
  • Modulated pulsed power (MPP) 스퍼터링은 펄스 전압 shape, amplitude, duration의 modulation을 통해 증착율 손실을 극복하는 고출력 펄스 마그네트론 스퍼터링의 한 종류이다. Micro second 범위에서 on/off 시간을 다중 세트 형태로 자유롭게 프로그램 할 수 있어서 아킹 없이 고전류 영역의 마그네트론 동작을 할 수 있으므로, 고주파 유도 결합 플라즈마원이나 마이크로웨이브 투입 등의 부가적인 플라즈마 없이도 스퍼터링 재료의 이온화 정도를 획기적으로 높일 수 있는 장점을 가지고 있다. 본 연구에서는 $2{\times}1{\times}0.2$의 sputtering system에서 기판 캐리어를 이용해서 $400{\times}400mm$ 기판을 $272{\times}500mm$ 크기의 AZO target (Al 2 wt%)이 설치되어 있는 moving magnet cathode (MMC)을 이용하여 MPP로 증착했다. 두 종류의 micro pulse set을 하나의 macro pulse에 사용함으로서 weakly ionized plasma와 strongly ionized plasma를 만들 수 있다. 다양한 micro pulse set을 이용하여 평균 전력 2 kW에서 peak 전력을 4 kW에서 45 kW까지 상승 시킬 수 있으며, 이 때 타겟-기판 거리 80 mm에서 이온전류밀도는 $5mA/cm^2$에서 $20mA/cm^2$까지 상승했다. MPP는 같은 평균 전력에서 repetition frequency가 증가할 때, 증착 속도가 증가했으며, 같은 repetition frequency에서 macro pulse length가 증가할 때도, 증착 속도가 증가했다. 최적화된 marco, micro pulse set에서 증착 속도는 평균 전력 2 kW에서 110 nm/min이었고, 700 nm의 박막에서 비저항은 $1-2{\times}10^{-3}ohm{\cdot}cm$였다. 표면거칠기 Rrms는 약 3 nm였고, 400-700 nm 영역의 평균 투과도는 72-76%였다.

  • PDF

Performance of Rake Receiver for Pulse Position Modulation-Time Hopping Ultra Wide Band Systems in Indoor Environments (실내 환경의 펄스 위치 변조-시간 도약 초광대역 무선통신 시스템에서 레이크 수신기 성능)

  • Kim, Joo-Chan;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.179-184
    • /
    • 2010
  • In this paper, we analyze and simulate the performance of RAKE receiver for ultra wide band (UWB) systems in indoor multipath radio channel. Pulse position modulation-time hopping (PPM-TH) signal is considered. And we also consider three types of RAKE receivers, which are ideal RAKE, selective RAKE, and partial RAKE receivers. The indoor channel is modeled as the modified Saleh and Valenzuela (SV) model which has been proposed as a UWB channel model by the IEEE group, IEEE 802.15.SG3a.

An overview of channel estimation for IR-UWB System (IR-UWB 시스템을 위한 채널 추정 기법)

  • Shin, Chang-Taek;Choi, Gin-Kyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.1-10
    • /
    • 2010
  • Impulse Radio Ultra-wideband (IR-UWB) system employing the short pulse has the tolerable characteristics for the multipath environment. The corresponding transceiver with low power consumption can be simply implemented. On the other hand, in the receiver side, the precise channel estimation is required for the knowledge of essence in channel due to the short period of pulse. The estimated gains and delays in channel are used in the rake receiver. The resulting parameters we search have a strong influence on the performance in the entire system. We introduce that the essential parameters can be obtained more precisely through the preamble in receiver side for the channel estimation and related technologies are presented.

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF