• Title/Summary/Keyword: 다공판

Search Result 137, Processing Time 0.039 seconds

The Acoustical Characteristics of an Absorptive Panel (흡음형 방음판넬의 음향특성)

  • Hwang, Cheol Ho;Jung, Sung Soo;Lee, Woo Seop;Kim, Yong Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1843-1850
    • /
    • 2000
  • Sound absorption coefficient for the absorptive panels comprized of a perforated plate. an absorbent material and an air gap was measured and compared with theoretical value. The absorptive panels are composed of three basic combinations (a perforated plate + an air gap + an absorbent material. a perforated plate + an absorbent material, a perforated plate + an absorbent material + an air gap). As a result. it is found that the sound absorption for low frequency range is strongly affected by the resonance produced by perforated plate and air gap. And the sound absorption for high frequency depends on the porosity of perforated plate.

  • PDF

Pool Boiling Enhancement of R-123 Using Perforated Plates (다공판을 사용한 R-123 풀비등 열전달 촉진)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.275-281
    • /
    • 2016
  • In this study, we investigate the pool boiling enhancement caused by perforated plates on top of a smooth surface. We conduct tests using R-123 at atmospheric pressure. It was shown that perforated plates significantly enhanced the pool boiling of the smooth surface. The reason may be attributed to the increased bubble contact area between the plates. The results showed that the enhancement ratio was dependent on the heat flux. At high heat flux, the enhancement ratio increased as the porosity increased. However, at low heat flux, the enhancement ratio decreased as the porosity increased. For the present investigation, the optimum configuration had a pore diameter of 2.0 mm, pore pitch of $2.5mm{\times}5.0mm$ or $5.0mm{\times}5.0mm$, and a gap width of 0.5 mm, which yielded heat-transfer coefficients that are close to those of GEWA-T. The optimum porosity for R-123 was significantly larger than that of water or ethanol. The reason for this may be the large liquid-to-vapor density ratio along with the small latent heat of vaporization of R-123. The perforated plates yielded smaller boiling hysteresis compared with that of the smooth surface.

Low frequency sound absorption improvement in refrigerator using multi perforated plate (다공판을 활용한 냉장고 저주파 흡음개선)

  • Ho-Jin, Kwon;Hyoung-Jin, Kim;Kyungjun, Song;Tae-hoon, Kim;Junhyo, Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.723-729
    • /
    • 2022
  • In this study, the multi perforated plate is used to reduce the compressor noise in the low frequency band inside the refrigerator machine room. To predict the sound absorption results, the impedance of the sound absorption material is measured. Using the measured impedance results, it is confirmed that the results used for FEM analysis is almost similar to the experimental values. The sound-absorbing structure that can operate in the target frequency band inside the refrigerator machine room is designed by controlling the hole diameter and arrangement in the perforated plate. The effect of reducing noise in the low frequency band is confirmed by applying perforated plate-based sound absorbing structures to the machine room.

Numerical Study of Impact for Particulate Matter Reduction Device According to Installation of Perforated Plate and Mixer on Marine Diesel Engine (선박용 디젤엔진의 미세먼지저감 장치에 다공판과 믹서의 장착이 미치는 영향에 대한 수치해석적 연구)

  • Yun, Byoungkyu;Cho, Sanghyun;Ryu, Younghyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.968-973
    • /
    • 2019
  • This study presents the characteristics of a pressure drop and uniformity index for a particulate matter reduction device with a perforated plate and mixer for marine diesel engines. The perforated plate and mixer equipped on the particulate matter reduction device induce an increase of exhaust gas reduction performance by increasing the uniformity index. Whereas, the perforated plate induces pressure drop increases in the particulate matter reduction device. Therefore to calculate the effect of the uniformity index and pressure drop of the perforated plates and mixer, this study combines several cases using five types of perforated plates and one type of mixer. Consequently, these results were analyzed to determine the optimized type and position of the perforated plate and mixer.

An Experimental Study for the Heat Transfer Augmentation of an Impinging Jet (충돌 분류의 열전달 특성향상을 위한 실험적 연구)

  • 정기호;김예용;김귀순
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.2
    • /
    • pp.66-74
    • /
    • 1999
  • In this study, the heat transfer augmentation without additional blower power was obtained by using punched plate. Though this scheme has some disadvantages such as decrease of momentum caused by the punched plate, it has significantly increased heat transfer coefficients in the stagnation region. Compared with the case of no punched plate, heat transfer coefficients were increased by punched plate more than 2 times near the optimum condition determined in this study. Liquid crystal and hue-capturing technique were used in this study to obtain heat transfer coefficients.

  • PDF

Experimental Study on Solar Air Collector with Perforated Endothermic Panels (흡열 다공판을 이용한 공기식 태양열 집열 유닛에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.455-459
    • /
    • 2010
  • In recent years, the crisis of energy is growing seriously and also the contamination of ecology has been reverberated as international problem. The social concerns on energy crisis have been growing for the last several years and also the interests in new and renewable energy have been increased. Therefore, in order to solving these problems, this study has dealt with the solar air collector with perforated endothermic panel to increase the indoor temperature. And also, the PV panel for running indoor air circulating fan has used to increase the convective heat transfer. From this study, the inlet air temperature is increased up to 42[$^{\circ}C$]. This temperature is enough to heat the indoor air condition during winter season. And also the result revealed that the mixing effect of convection is increased with increasing in fan circulating power.

The Effect of Partitioning Porous Plate on Bubble Behavior and Gas Hold-up in a Bench Scale (0.36 m × 22 m) Trayed Bubble Column (벤치스케일(0.36 m × 22 m) 다단형 기포탑에서 다공판이 기포의 거동 및 기체 체류량에 미치는 영향)

  • Yang, Jung Hoon;Hur, Young Gul;Lee, Ho-Tae;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Park, Ji Chan;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.505-510
    • /
    • 2012
  • The gas hold-up has a strong relationship with the size distribution and rising velocities of bubbles in a bubble column. Therefore, many previous researchers have studied on the hydrodynamics focusing on the bubble size variation in bubble column. In this study, the bubble behavior was influenced by partitioning porous plates installed at a certain height in a trayed bubble column. The gas hold-up was increased in non-sparging region (H/D > 5) as well as sparging region. We identified the effect of the partitioning porous plate using three trayed bubble columns with different reactor geometries. Furthermore, the bubble break-up frequency and size distribution were observed before and after individual bubbles penetrated through the plate. The arrangement of the plates was also investigated using a 0.15-m-in-diameter bubble column. Based on the result, we applied this design concept to a 0.36-m-in-diameter, 22 m tall trayed bubble column and identified the effect of the partitioning porous plate on the gas hold-up increase.

A Flat Loudsspeaker driven by Multi-layer diaphragm (다층 진동판으로 구동되는 평판 스피커)

  • Yi H.R.;Kim B.N.;Oh S.J.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.131-136
    • /
    • 2004
  • 스피커는 진동판의 크기와 형태 외에도 소재 또는 내부구조에 따라 구동 특성이 달라진다. 본 연구에서는 동일한 신호가 입력되는 두 진동판 사이에 공동을 형성시킨 경우, 다공성 흡음재를 삽입한 경우 스피커의 특성 변화를 관측하였다. 특히, 다공성 흡음재를 삽입한 경우, 다공성 물질의 체적을 동일하게 하고 진동판 표면 상태에 따른 영향과 진동판 상의 진동 전달 경로에 의한 영향을 제거하여 내부물질에 따른 특성의 변화를 측정하였다.

  • PDF