• Title/Summary/Keyword: 다가구주택 반지하세대

Search Result 2, Processing Time 0.021 seconds

An analysis of the Influencing Factors and Actual State of Indoor Air Quality in Semi-underground Multi-family Housing Units (다가구주택 반지하세대의 실내공기질 실태 및 영향요인 분석)

  • Choi, Yoon-Jung;Kim, Sun-Young;Kim, Ji-Young;Choe, Sol-Ji
    • Korean Journal of Human Ecology
    • /
    • v.20 no.5
    • /
    • pp.1075-1091
    • /
    • 2011
  • The purposes of this study were to investigate the actual state of indoor air quality in semi-underground multi-family housing units in early summer, to analyze the influencing factors, and to make suggestions for improvement. A series of field investigations were conducted in four target units between June 22, 2010, and June 28, 2010. The field investigations included measurements of indoor air quality as well as the observation of architectural characteristics and living conditions. In addition to the field investigation, on-site questionnaire surveys were administrated to residents in 90 units. The findings are summarized as follows: (1) The average $CO_2$ levels in each of the four units ranged from 759ppm to 1885ppm. $CO_2$ levels in three units exceeded the evaluation standard (1000ppm), and one unit was lower than the standard. This unit had smaller number of staying person and a large amount of ventilation than others; (2) the average CO levels in each unit were almost 0ppm, but 0.1~1.1 levels of CO were revealed at several times; (3) the average PM-10 levels ranged from $8{\mu}g/m^3$ to $40{\mu}g/m^3$, which distributes within the standard ($150{\mu}g/m^3$). The influencing factors of PM-10 levels were analyzed as inflow from outside, the use of a gas range, and the residents' activities; (4) therefore, it was evaluated to be necessary to improve ventilation for the indoor air quality of semi-underground housing in aspect of $CO_2$ levels.

Analysis of Housing Environment in Semi Basement Multi-family Housing Units - Focuses on long-term analyzed measurements of temperature and humidity obtained from the housing units - (다가구 주택 반지하세대의 주거환경 분석 - 장기 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.83-90
    • /
    • 2018
  • This study was conducted to investigate the living environment of semi-basement housing units in multi-household houses. It analyzed measurements of temperature and humidity obtained from the housing units. For this study, temperature and humidity sensors were installed in 10 semi-basement housing units to measure interior temperature and humidity for 13 months. A survey was conducted to get information about the occurrence of dew condensation and mildew and to investigate residents' satisfaction level with the residential environment. According to the result, all the housing units under study had dew condensation and mildew. The average summer temperature of the 10 housing units was $27.84^{\circ}C$, and average humidity was 64.91%RH, while the average winter temperature was $20.6^{\circ}C$, and the average humidity was 40.12%RH. Depending on the condition of each housing unit, deviation was big. Residents' average level of satisfaction with the living condition was 2.03 which shows a low satisfaction (on a scale of 1-5 with 5 being completely satisfied.).