• Title/Summary/Keyword: 니켈-타이타늄 파일

Search Result 7, Processing Time 0.014 seconds

THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE (수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구)

  • Lim, Jung-Jang;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2005
  • The purpose of this study was to evaluate which type of Ni-Ti files are able to maintain canal configuration better in the simulated canal with abrupt curvature near it's apex. Ninety six simulated root canals were made in epoxy resin and $\sharp$15 finger spreader was used as root canal templates. The simulated root canals were made with radius of curvature of 1.5mm, 3.0mm, 4.0mm, 6.0mm respectively and the angle of curvature of all simulated canals were adjusted to 90 degree. The simulated canals were instrumented by ProFile, ProTaper, Hero 642, and $K^3$ at a 300 rpm using crown-down pressureless technique. Pre-instrumented and post-instrumented images were taken by digital camera and were superimposed with Adobe Photos hop 6.0 program. Images were compared by image analysis program. The changes of canal width at the inner and outer side of the canal curvature. canal transportation were measured at 9 measuring point with 1 mm interval. Statistical analysis among the types of Ni-Ti files was performed using Kruskal-Wallis test and Mann-Whitney U-test. The result was that ProFile maintain original canal configuration better than other engine driven Ni-Ti files in the canals above 3.0mm radius of curvature, and in the 1.5mm radius of curvature, most of Ni-Ti flies were deformed or separated during instrumentation.

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

The Efficiency of the Ni-Ti Rotary Files in Curved Simulated Canals Shaped by Novice Operators (만곡모형근관에서 초심자가 근관형성시 Ni-Ti 전동파일의 효용성)

  • Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.146-155
    • /
    • 2003
  • 여러 가지 장점으로 인해 Ni-Ti 전동 파일을 근관성형에 사용하는 빈도가 점차 증가되는 추세이지만, 초심자를 대상으로 한 연구는 부족한 실정이다. 이에 본 연구에서는 초심자에서 Ni-Ti 전동 파일을 사용할 때 근관 형성의 효용성을 평가하고, 어떤 방법이 초심자에게 적절한지를 알아보고자 하였다. 근관형태가 재현된 레진 블록을 이용하여 12명의 초심자와 4명의 숙련자가 근관 형성을 시행하였다. 각 술자는 ProFile, ProTaper, Hybrid (ProFile+ProTaper)를 이용하여 각각의 레진 블록을 세 개씩 근관형성하고, 각 파일 별의 근관 형성 시간을 기록하였다. 근관 형성 전과 후의 digital 이미지를 중첩하여 치근단으로부터 1, 2, 3, 4, 5, 6, 7mm level에서 근관단면의 총길이 변화량, 만곡 외측의 길이 변화량, 만곡 내측의 길이 변화량, 중심이동량, 중심이동율과 치근단에서의 apical transportation을 구하고, 초심자와 숙련자 사이의 차이를 비교 평가하였다. 실험결과 ProFile군의 1, 3, 5, 6, 7mm level과 ProTaper군의 6mm level, Hybrid군의 3mm level에서 초심자의 근관단면의 총길이 변화량이 숙련자보다 많았다. 모든 군에서 치근단으로부터 4, 5, 6, 7mm level에서는 근관 중심이 만곡내측으로 이동하였고, 1 2, 3mm level 에서는 만곡외측으로 이동하였으나, 숙련자가 시행한 Hybrid군의 3mm level과 비숙련자가 시행한 ProTaper 군의 3mm level에서는 만곡내측으로 이동하였다. 모든 군의 3mm level과 ProFile 군의 5mm level에서 초심자의 중심이동율이 숙련자에 비해 컸으며, 초심자가 ProTaper를 사용시 더 큰 apical trans portation을 보였고, 모든 군에서 초심자가 근관형성시 더 많은 시간이 걸렸다. ProFile과 ProTaper를 이용한 Hybrid technique이 초심자에게 추천되며, 초심자들도 충분히 교육받는다면 만곡된 근관의 근관형성에 있어서 Ni-Ti rotary file의 이용이 가능하리라고 사료된다.

SCANNING ELECTRON MICROSCOPIC STUDY ON THE EFFICACY OF ROOT CANAL WALL DEBRIDEMENT OF ROTARY NI-TI INSTRUMENTS WITH DIFFERENT CUTTING ANGLE (엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구)

  • Jeon, In-Soo;Yoon, Tai-Cheol;Park, Seong-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.577-586
    • /
    • 2002
  • The purpose of this in vitro study was to compare the effects of root canal cleanness following two Ni-Ti rotary instruments with different rake angle. Thirty-six sound, extracted human premolars with single root were randomly divided into three groups. The used rotary instruments were HEROShaper (Group 1, Micro-Mega, Besancon, France, n=12) and ProFile (Group 2, Maillefer, Ballaigues, Switzerland, n=12). Control group (n=12) was only extirpated with barbed broach (Mani, Matsutani Seisakusho Co., Japan) Group 1 & 2 teeth were prepared to a #40/.04 taper at the apex followed by 1 mm using crown-down technique. After canal preparation and frequent irrigation with 5.25% sodium hypochlorite, the roots split longitudinally into a bucco-lingual direction. Root halves were cross-sectioned in apical third portion again. All root specimens were processed for SEM investigation and photographed. Separate evaluations by one endodontist were undertaken for smear layer on prepared walls with a five score-index for each using reference photograph in root halves. The penetration depth of smear layer into dentinal tubules was also estimated in the other halves. Following results were obtained: 1. Smear layer was observed on all the prepared walls with two experimental groups except control group. 2. Smear layer characteristics in two experimental groups; 1) HEROShaper group showed snowy, dusty appearance and were shown open dentinal tubuli on the prepared walls of almost specimens, and the thickness of smear layer covering onto dentinal surfaces was within 1-2 ${\mu}m$ in a few specimens. 2) ProFile group showed shiny, burnished appearance and complete root canal wall covered by a homogenous smear layer with no open dentinal tubuli in all specimens. The penetration of smear layer into dentinal tubules was found in all specimens and the thickness was at 2-4 ${\mu}m$ in all specimens. These results demonstrated that a completely clean root canal could not be achieved regardless of positive or negative rake angle, which is in accordance with the majority of previous studies on root canal cleanliness In conclusion, through irrigation with antibacterial solutions or chelating agents is recommended to remove the smear layer on prepared canal wall in spite of Ni-Ti instrumentation.

COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS (모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교)

  • Kum, Kee-Yeon;Lim, Kyoung-Ran;Jung, Il-Young;Lee, Sung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

CYCLIC FATIGUE OF THE SODIUM HYPOCHLORITE TREATED AND /OR STEAM AUTOCLAVED NICKEL-TITANIUM ENDODONTIC FILES (차아염소산나트륨 용액과 고압증기멸균이 근관치료용 니켈-타이타늄 파일의 주기적 피로 파절에 미치는 영향)

  • Cho, Hye-Young;Jung, Ii-Young;Lee, Chan-Young;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.54-65
    • /
    • 2008
  • The purpose of this study was to determine the effect of sodium hypochlorite and steam autoclaving on the cyclic fatigue of nickel-titanium endodontic files. Two types of files with a .06 taper and #30 were used, $K3^{(R)}$ (SybronEndo, Glendora, California, USA) and Hero $642^{(R)}$(Micro-Mega, BesanCon, France). The files were divided into 6 experimental groups containing 10 files each group depending the soaking time in 6% sodium hypochlorite solution and number of cycles of steam autoclave. After sterilization, a cyclic fatigue test was performed on each file, and the fracture time was recorded in seconds. The control group underwent the cyclic fatigue test only. After the test, the surface characteristics of the files were observed using scanning electron microscopy (SEM). All groups containing the Hero 64~ files showed a similar cyclic fatigue fracture time. However, the cyclic fatigue fracture time with the $K3^{(R)}$ files was significantly shorter in groups which were treated with sodium hypochlorite than in the control group (P < 0.05), SEM revealed both Hero $642^{(R)}$ and $K3^{(R)}$ files to have significant corrosion on the file surface in groups treated with sodium hypochlorite, compared with the sharp and regular blades of the control group. $K3^{(R)}$ files showed more corrosion than the Hero $642^{(R)}$ files. Bluntness of the blades of the $K3^{(R)}$ file was observed in groups treated with steam autoclave. Although there was no obvious destruction on the surface of steam autoclaved Hero $642^{(R)}$ files, slight bluntness was observed. Sterilizing with a steam autoclave is much less destructive to $K3^{(R)}$ files than sodium hypochlorite. The longer time exposed to sodium hypochlorite, the more destructive pattern was shown on the blades of the files. Therefore, when using sodium hypochlorite solution, the exposure time should be as short as possible in order to prevent corrosion and increase the cyclic fatigue fracture time.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.