• Title/Summary/Keyword: 니켈티타늄

Search Result 70, Processing Time 0.031 seconds

COMPARISON OF THE BOND STRENGTH OF CERAMICS FUSED TO TITANIUM AND Ni-Cr ALLOY (티타늄과 니켈-크롬 합금의 도재결합강도 비교)

  • Park Sae-Young;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.89-98
    • /
    • 2003
  • Titanium requires special ceramic system for veneering. Low fusing dental ceramics with coefficients of thermal expansion matching that of titanium have been developed. The purpose of this study was determine the bond strengths between cast and noncast pure titanium and two commercial titanium porcelains, and to compare the results with a conventional nickel-chromium alloy-ceramic system. The bond strengths were determined using a 3-point flexure test. Three-point flexure specimens $25{\times}3{\times}0.5mm$ were prepared After removal of ${\alpha}-case$ layer, they were veneered with $8{\times}3{\times}1mm$ of ceramics at the center of the bar. Specimens were tested in a universal testing machine. Within the limits of this study, the following conclusions were drawn: 1. The bond strengths between pure titanium and two commercial porcelains exceeded th lower limit of the bonding strength value in ISO 9693(25MPa). 2. There was no significant difference between cast and noncast titanium-porcelain bonds. 3. There was no significant difference between two commercial titanium porcelains. 4. The bond strengths of the titanium-porcelain systems ranged from 73% to 79% of that of the Ni-Cr-conventional porcelain system.

ABILITY OF NICKEL-TITANIUM FILES IN MAINTAINING THE ORIGINAL CURVATURE OF A CURVED ROOT CANAL AND ITS ANALYSIS BY FINITE ELEMENT METHODS (만곡 근관 형성시 니켈-티타늄 파일의 만곡 유지 능력과 그에 대한 유한요소법적 분석)

  • Park, Han-Soo;Lim, Sung-Sam;Bae, Kwang-Shik;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.220-227
    • /
    • 1997
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with NiTi and stainless steel files, and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. By finite element methods we also analyzed stress distributions of NiTi and stainless steel files in a curved canal. The results were as follows : 1. NiTi files were excellent in maintaining the original curvature of a curved canal than stainless steel files after canal preparation. 2. The results of canal preparation with these files were well verified by the analysis of stress distributions using finite element methods.

  • PDF

THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS (엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과)

  • Jeon, Jeong-Hun;Min, Jeong-Beom;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.

SCANNING ELECTRON MICROSCOPIC STUDY ON THE EFFICACY OF ROOT CANAL WALL DEBRIDEMENT OF ROTARY NI-TI INSTRUMENTS WITH DIFFERENT CUTTING ANGLE (엔진 구동형 니켈-타이타늄 합금파일의 절삭각에 따른 근관성형 효과에 관한 전자현미경적 연구)

  • Jeon, In-Soo;Yoon, Tai-Cheol;Park, Seong-Ho;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.577-586
    • /
    • 2002
  • The purpose of this in vitro study was to compare the effects of root canal cleanness following two Ni-Ti rotary instruments with different rake angle. Thirty-six sound, extracted human premolars with single root were randomly divided into three groups. The used rotary instruments were HEROShaper (Group 1, Micro-Mega, Besancon, France, n=12) and ProFile (Group 2, Maillefer, Ballaigues, Switzerland, n=12). Control group (n=12) was only extirpated with barbed broach (Mani, Matsutani Seisakusho Co., Japan) Group 1 & 2 teeth were prepared to a #40/.04 taper at the apex followed by 1 mm using crown-down technique. After canal preparation and frequent irrigation with 5.25% sodium hypochlorite, the roots split longitudinally into a bucco-lingual direction. Root halves were cross-sectioned in apical third portion again. All root specimens were processed for SEM investigation and photographed. Separate evaluations by one endodontist were undertaken for smear layer on prepared walls with a five score-index for each using reference photograph in root halves. The penetration depth of smear layer into dentinal tubules was also estimated in the other halves. Following results were obtained: 1. Smear layer was observed on all the prepared walls with two experimental groups except control group. 2. Smear layer characteristics in two experimental groups; 1) HEROShaper group showed snowy, dusty appearance and were shown open dentinal tubuli on the prepared walls of almost specimens, and the thickness of smear layer covering onto dentinal surfaces was within 1-2 ${\mu}m$ in a few specimens. 2) ProFile group showed shiny, burnished appearance and complete root canal wall covered by a homogenous smear layer with no open dentinal tubuli in all specimens. The penetration of smear layer into dentinal tubules was found in all specimens and the thickness was at 2-4 ${\mu}m$ in all specimens. These results demonstrated that a completely clean root canal could not be achieved regardless of positive or negative rake angle, which is in accordance with the majority of previous studies on root canal cleanliness In conclusion, through irrigation with antibacterial solutions or chelating agents is recommended to remove the smear layer on prepared canal wall in spite of Ni-Ti instrumentation.

The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals (만곡된 레진 모형 근관에서 4종의 엔진 구동형 니켈-티타늄 기구의 근관 중심율 유지 능력)

  • Ku, Jae-Hoon;Chang, Hoon-Sang;Chang, Seok-Woo;Cho, Hwan-Hee;Bae, Ji-Myung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2006
  • The aim of this study was to evaluate the ability of newly marketed NRT instruments to maintain the original root canal configuration and curvature during preparation in comparison with the three existing instruments in simulated root canals. Simulated canals in resin blocks were prepared with ProFile. K3, ProTaper and NRT instrument (n = 10 canals in each case). Pre- and post-operative images were recorded, and assessment of canal shape was completed with a computer image analysis program. The data were analyzed statistically using the One-way ANOVA followed by Duncan s test. The ability or instruments to remain centered in prepared canals at 1-, 2-mm levels was significantly better in ProFile groups than in other groups (p < 0.05). The change of centering ratio in NRT groups at 5-mm level was significantly greater than ProFile group and at 6- and 7-mm level than all other groups (p < 0.05). Although the NRT system was comparable to other systems in regards to its ability to maintain the canal configuration of apical portion, this system was more influenced by the mid-root curvature due to its stainless-steel files for coronal preflaring.

Development of the New Austenitic Stainless Steels by Controlling Primary Solidification Mode (초정응고 형식 제어에 의한 오스테나이트계 스테인리스 신강종의 개발)

  • 정호신
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.2
    • /
    • pp.132-140
    • /
    • 1991
  • The aim of this study was saving of chromium and nickel content in the austenitic stainless steels, SUS 316 and SUS 321. By control of primary solidification mode, new austenitic stainless steels with good weldability, high toughness and corrosion resistance could be developed. The main results obtained were as follows; 1. Hot crack resistance of laboratory melts was good and higher than imported austenitic stainless steel. 2. Cryogenic and room temperature toughness of laboratory melts were high and laboratory melts M-7 to M-9 showed very high toughness than SUS321 imported stainless steel. 3. Intergranular corrosion resistance of laboratory melts was higher than imported stainless steels, SUS316 and SUS321. 4. By this concept of controlling primary solidification mode, could save expensive alloy additives, chromium and nickel.

  • PDF

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

Evaluation of Elution Characteristics by Material for Kitchen Utensils - Focusing on the Metallic Kitchen Utensils (유통 주방기구의 재질별 용출 특성 평가 -금속제 주방기구 중심으로-)

  • Kim, Jae-Kwan;Im, Kyung-Sook;Kim, Myung-Gil;Park, Sung-Hee;Seo, Mi-Young;Lee, Yu-Na;Kim, Jung-Sun;Ku, Eun-Jung;Chae, Sun-Young;Park, Yong-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.51-59
    • /
    • 2021
  • In this study we analyzed the elution rates of 11 metals from 82 metallic kitchen utensils purchased in the market. The elution frequency of the 11 types of metals was iron > aluminum > chromium, nickel > zinc > copper > lead > arsenic > antimony > stannum > cadmium. For metallic kitchen utensils, the elution rate of heavy metals was 7.3-93.9%, and the average elution concentration was 0.001-13.473 mg/L. The average elution concentration of heavy metals was ranged between none-detected (N. D.) to 30.473 mg/L for non-coated kitchen utensils and 0.000-10.005 mg/L for coated kitchen utensils. The average elution concentration of metals from domestic kitchen utensils ranged from 0.001-25.145 mg/L, and from 0.000-33.518 mg/L for imported kitchen utensils. In particular, aluminum was found to be high in domestic kitchen utensils while iron was high in imported kitchen utensils. The average elution concentration of heavy metals was N.D.-2.670 mg/L for stainless steel, N.D.- 31.575 mg/L for aluminum, and N.D.-307.737 mg/L for iron. The amount of transition to food after cooking was investigated.

SUPERELASTICITY OF CAST SHAPE MEMORY Ni-Ti ALLOY (주조 형상기억 니켈-티타늄 합금의 초탄성)

  • Choi, Dong-Ik;Choie, Mok-Kyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.3 no.1
    • /
    • pp.32-43
    • /
    • 1995
  • Ni-Ti alloy has excellent corrosion resistance, biocompatibility, shape memory effect and superelasticity, so it has been used widely in biomedical fields. But it has difficulty in casting due to its high melting temperature and oxygen affinity at high temperature. Recently it has been attempted to cast Ni-Ti alloy using new casting machine and investment. The purpose of this study was to examine the superelastic behavior of cast shape memory Ni-Ti alloy and to compare the mechanical properties of the cast shape memory alloy with those of commercial alloys for removable partial denture framework. Ni-Ti alloy(Ni 50.25%, Ti 49.75% : atomic ratio) was cast with dental argon-arc pressure casting machine and Type IV gold alloy, Co-Cr alloy, Ni-Cr alloy, pure titanium were cast as reference. Experimental cast Ni-Ti alloy was treated with heat($500{\pm}2^{\circ}C$) in muffle furnace for 1 hour. Transformation temperature range of cast Ni-Ti alloy was measured with differential scanning calorimetry. The superelastic behavior and mechanical properties of cat Ni-Ti alloy were observed and evaluated by three point bending test, ultimate tensile test, Vickers microhardness test and scanning electron microscope. The results were as follows : 1. Cast Ni-Ti alloy(Ni 50.25%, Ti 49.75% : atomic ratio) was found to have superelastic behavior. 2. Stiffness of cast Ni-Ti alloy was considerably lesser than that of commercial alloys for removable partial denture. 3. Permanent deformation was observed in commercial alloys for removable partial denture framework at three point bending test over proportional limit(1.5mm deflection), but was not nearly observed in cast Ni-Ti alloy. 4. On the mechanical properties of ultimate tensile strength, elongation and Vickers microhardness number, cast Ni-Ti alloy was similiar to Type IV gold alloy, Co-Cr alloy, Ni-Cr alloy and pure titanium. With these results, cast Ni-Ti alloy had superelastic behavior and low stiffness. Therefore, it is suggested that cast Ni-Ti alloy may be applicated to base metal alloy for removable partial denture framework.

  • PDF

The Evaluation of Electrolytic Nitrate Removal Efficiency of TiO2 Nanotube Plate (TiO2 nanotube plate의 질산성질소 전기분해 효율 평가)

  • Kim, Da Eun;Lee, Yongho;Han, Heeju;Choi, Hyo yeon;Pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.612-621
    • /
    • 2018
  • In this study, $TiO_2$ nanotube plate and metal electrodes(Copper, Nickel, Stainless Steel, Aluminum, Tin, Titanium) were compared on cathodic reduction of nitrate ($NO_3{^-}-N$) during electrolysis. The electrochemical characteristics were compared based on electrochemical impedance spectroscopy (EIS). The surface morphology was obtained using scanning electron microscopy (SEM) method. Brunauer-Emmett-Teller (BET) method was implemented for the specific surface area analysis of the cathodes. To study kinetics, 90 minute batch electrolysis of nitrate solution was performed for each cathodes. In conclusion, under the condition of relatively low ($0.04 A\;cm^{-2}$) current density, $TiO_2$ nanotube plate showed no surface corrosion during the electrolysis, and the reaction rate was measured the highest in the kinetic analysis.