• Title/Summary/Keyword: 니켈티타늄

Search Result 70, Processing Time 0.025 seconds

THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS (엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향)

  • Roh, Hyoung-Mee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.486-492
    • /
    • 2005
  • The purpose of this study was to compare the shaping ability of the two different Ni-Ti file systems and the two different engine systems in simulated canals. A total of four groups of each 10 were tested. Each group was instrumented with HeroShaper and Endo-Mate2 (Croup HE), HeroShaper and Tecnika (Croup HT), ProFile and Endo-Mate2 (Group PE), and ProFile and Tecnika (Croup PT). Canal preparation time was recorded. The images of pre- and post- instrumented root canals were scanned and superimposed. The amounts of increased width and centering ratio were measured and calculated at apical 1, 3 and 5mm levels. These data were statistically analyzed with one-way ANOVA and Duncan's multiple range test The results of this study were as fellows ; 1. Canal preparation time of HT group was the shortest (p<0.05). 2. The amount of increased canal width in HE group was significantly larger than PT group at apical 1mm level (p<0.05) At apical 3mm level, PT group was significantly smaller than other groups (p<0.05). At apical 5mm level, PE group was significantly larger than PT group (p<0.05). 3. The amount of centering ratio in HE group was significantly larger than other groups (p<0.05). At apical 5mm level, HT group was significantly larger than PE group and PT group (p<0.05). Under the condition of this study, torque-controlled endodontic motor is safer than no torque controlled motor, especially when the active file is used.

Heavy Metals and Cosmetics (화장품과 중금속)

  • 김영소;정혜진;장이섭
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.1
    • /
    • pp.15-30
    • /
    • 2002
  • 최근 화장품 사용인구의 증가와 안전성에 대한 관심 증대에 따라 화장품 중 유해성분 함유에 대한 논란이 종종 있어왔다. 화장품에 대한 전문적 지식이 없는 사람들에 의하여 진행된 잘못된 정보로 인하여 화장품 중에 포함된 모든 중금속이 인체에 심각한 영향을 초래한다는 등의 오해를 불러와 관련 업계에 적지 않은 피해를 주기도 하였다. 이에 본 자료에서는 구체적 근거자료와 연구 논문들을 기반으로 유해한 중금속, 안전하여 사용이 공인된 중금속 등을 조사하여 화장품에서의 중금속의 개념을 정립하고자 하였다. 국내에서는 식품의약품안전청 고시 제2000-27호에 화장품에 포함되었을 때 유해한 중금속으로 납, 비소 및 수은을 명시하고 그 규제농도를 규정하고 있다. 규제 중금속은 아니지만 피부에 알러지를 일으키는 중금속으로는 니켈이 있는데 화장품 중 몇몇 제품군에서 소량(수∼수십ppm) 이 검출되기도 한다. 그러나 이는 일상으로 사용하는 각종 귀금속, 시계, 안경테, 클립, 지퍼 등의 금속 용품에 포함된 니켈의 양(수∼수십%)에 비하여 매우 적은 양이며 정상적인 사람에게는 무해하다. 실제 대다수의 니켈 알러지는 화장품이 아닌 귀금속이나 시계 등의 금속류 제품 등에 의하여 유발된다. 또한 많은 종류의 중금속 화합물이 화장품 원료로 사용되고 있다. 전세계적으로 널리 사용되는 것으로 크롬, 망간, 비스머스, 구리, 철, 코발트, 티타늄, 아연 등의 화합물이 있으며 이들은 각종 화장품 공정서 및 원료집 등에 수재되어 사용되고 있다. 이들 중 코발트와 크롬이 피부에 유해하다는 몇몇 보고가 있지만, 이는 이들 원소의 수용성염형태의 특정 화합물인 cobalt chloride와 chromate 및 dichromate의 염에 관한 것으로 화장품에서 사용되는 불용성 산화물인 cobalt aluminum oxide, cobalt titanium oxide, cobalt blue, chromium oxde greens 및 chromium hydroide green 등, 국제적으로 널리 사용되는 안전한 중금속 화합물과는 그 특성 및 독성이 판이하게 다르다. 따라서 화장품에서는 매우 안전한 중금속 화합물만이 사용된다. 업계는 유해 중금속에 관해서는 규제에 입각한 엄격한 품질관리에 힘쓰고 중금속의 화학적 분자구조(수용성염 vs 불용성산화물)를 구별할 수 있는 분석방법 개발에 주력하여야 한다. 그리고 안전한 화장품을 사용하고자 하는 소비자의 욕구를 충족시키고 잘못된 인식과 보도로 인하여 안전한 화장품이 유해한 것으로 오도되는 것을 막아야 할 것이다.

A study on the fabrication process development of FeTi type alloy for Ni/MH battery (니켈-수소 2차전지용 철-티타늄계 전극용 합금제조 공정에 관한 연구)

  • Lee, Moon-Goo;Kim, Eul-Su;Jeong, Sun-Dol;Kim, Ki-Won;Ahn, Hyo-Jun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In order to study on the effect of fabrication methods on the changes of hydrogenation properties of FeTi alloy, FeTi samples were prepared using three different methods, i.e., arc melting, mechanical alloying and combination of the two methods. The FeTi prepared by mechanical alloying represented amorphous structure. The hydrogen storage capacity of arc melted FeTi alloy is larger than any other samples. However, FeTi electrode fabricated by mechanical alloying after arc melting showed largest discharge capacity among them.

  • PDF

A review regarding on design of engine-driven nickel-titanium file (임상가를 위한 특집 2 - 엔진구동형 니켈-티타늄 파일의 디자인에 관한 고찰)

  • Hwang, Ho-Keel
    • The Journal of the Korean dental association
    • /
    • v.51 no.10
    • /
    • pp.551-555
    • /
    • 2013
  • The purpose of this study was to give a guideline for selecting the nickel-titanium (NiTi) file by review from many studies. Since the early 1990s, several instrument systems manufactured from NiTi have been introduced into endodontic practice. The specific design characteristics vary, such as tip shape and size, cross sectional view, helix angle, and pitch space. Some of the early systems have been removed from the market or play only minor roles; others are still widely used. New designs continually are produced, but the extent to which clinical outcomes will depend on design characteristics is difficult to forecast. In this study, I have reviewed the different design characteristics in respect of the safety and efficiency. With the review from many studies, I concluded that the clinicians must be understand the specific design characteristics for selecting the ideal NiTi rotary instruments.

High Density Energy Welding of Gas Turbine Alloys

  • Kim, Hwan-Tae
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.140-142
    • /
    • 2001
  • 항공기의 제트 엔진을 비롯하여 육상용 발전기, 선박용 엔진, 로켓 엔진 등에 널리 사용되는 터빈 블레이드를 포함한 고온용 가스터빈 부품은 최대 온도 120$0^{\circ}C$ 이상의 고온에 노출되어 가혹한 기계적 응력을 받는 동시에 고온에서의 표면 안정성이 요구되므로 초내열 니켈 합금(superalloy), 티타늄 합금, 내열강 등의 고온강도가 우수한 합금이 사용된다. 그런데 합금성분이 많이 첨가된 내열 합금을 용접하는 경우, 미세균열, 용접부의 기계적 성질의 저하, 용접열영향부의 내식성과 내산화성의 저하, 용접외부 결함에 의한 피로강도 저하 등의 문제가 발생하므로 이를 해결해야 한다. 본고에서는 생산성과 용접품질이 우수한 고밀도 에너지빔 용접의 적용 현황에 관하여 고찰코자 한다.

  • PDF

Prospects and Status of Intermetallic Compounds for High Temperature Applications (고온용 신소재 금속간화합물의 현황과 전망)

  • 정석주
    • Journal of the KSME
    • /
    • v.34 no.5
    • /
    • pp.392-398
    • /
    • 1994
  • 구조용 고온재료로서 표 2에 나타내듯이 지금까지 니켈과 티타늄 알루미나이드($Ni_3Al$, NiAl, $Ti_3Al$, TiAl에 관하여 집중적인 연구가 진행되어 왔으며 다른 금속간 화합물에 대해서도 광범위한 연구가 진행중이다. 그 예로서 $Co_3Ti$는 800.deg. C에서 최대강도를 보이며 저온에서는 온도가 감소하면서 강도가 다시 증가하면 연성이라는 장점을 지닌 관계로 $MoSi_2$는 높은 융점과 우수한 산화저항력 때문에 $Nb_2Al$은 높은 융점과 경량성 때 문에 복합재료의 matrix로서 최근 주목을 받고 있다. 끝으로 비록 금속간화합물이 취성이라는 단점 때문에 실용화에 많은 문제점이 있으며 본 재료에 관한 연구가 준비 제조공정과정에서 수 소취성화, 고용점온도 취성 등으로 인하여 사용해온 기존의 재료를 보다 좀더 극한 상황에서 가볍고 저렴하게 사용할 수 있는 우주항공 및 지상대체재료로서 개발할 수 있음을 고려할 때 본 재료에 대한 본격적인 연구가 국재 경쟁력강화를 위해 신소재 개발에 부심하는 우리나라에서도 이루어질 필요가 있다.

  • PDF

Electrodeposition of Nano TiO2 Powder Dispersed Nickel Composite Coating (전기도금법을 이용한 나노 산화티타늄 니켈 복합도금에 관한 연구)

  • Park, So-Yeon;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.4
    • /
    • pp.65-69
    • /
    • 2012
  • Composite coating can be manufactured during the electroplating with the bath containing a suspension of particles: ceramic, polymer, nanopowders. Improvement of hardness, wear resistance, corrosion resistance and lubrication properties are well-known advantage of composite coating. In this study, nano $TiO_2$ powder dispersed Ni composite plating was investigated. The improvement of surface hardness and photo decomposition effects can be expected in this coating. Zeta potential was measured with pH. The effect of ultrasonication time and types of ultrasonicator were studied to minimize the agglomeration of $TiO_2$ nanopowders in the electrolyte. Optimum conditions for nano $TiO_2$ dispersed Ni composite coating were $40mA/cm^2$ of current density, pH 3.5, and $50^{\circ}C$. At these conditions, $TiO_2$ nanoparticles contents in the Ni deposit was 15-20 at.%.

Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study (Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구)

  • Kim, Hyeon-Cheol;Kwak, Sang Won;Ha, Jung-Hong
    • The Journal of the Korean dental association
    • /
    • v.55 no.10
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro (니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro)

  • Kwak, Sang Won;Ha, Jung-Hong;Ahn, Sang Mi;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

Comparison of the centering ratio and canal curvature reduction according to the apical preparation size using various NiTi rotary instruments (근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교)

  • Kwak, Sang-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.47 no.7
    • /
    • pp.435-443
    • /
    • 2009
  • The purpose of this study was to compare the centering ratio and reduction of canal curvature according to the preparation sizes of #30, #40 and #50 using three rotary NiTi instruments which have different shaft tapers. Seventy-two simulated root canals in clear resin blocks (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland) were divided as following 3 groups according to the file system; the 24 canal blocks prepared with each of ProTaper Universal system (Group P), LightSpeed eXtra system (Group L), and K3 (Group K). The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the centering ratio and reduction of canal curvature. Mean scores of each group were statistically analyzed using one-way ANOV A and Duncan's multiple range test for post-hoc comparison. The results were as followings: 1. Group L showed better centering ratio, followed by K and P. And all experimental groups generally showed increasing tendency of centering ratio as the apical size was increasing from #30 to #50, except at 1 mm level of group P where showed reducing tendency of centering ratio. The smaller the ratio, the better the instrument remained centered in the canal. 2. Group P showed more decrease of canal curvature at all apical shaping size (p < 0.05). Under the conditions of this study, the shaft design could affect the quality of canal shaping and the smooth taperless flexible (LightSpeed) shaft design was capable of preparing canals with good morphological characteristics in curved canals.

  • PDF