Active Tonal Noise Control to Reduce the Low Frequency Tonal Sound (저주파 순음소음저감을 위한 능동 순음 소음제어)

  • 나희승;박영진
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1037-1042
    • /
    • 1998
  • This paper discusses the dependence of the convergence rate on the acoustic error path in these popular algorithms and introduces new algorithms which increase the convergence region regardless of the time-delay in the acoustic error path. We also Propose a novel control algorithm (AFC/CAFC) for tonal noise cancellation. The proposed algorithm estimates the magnitude and phase of the tonal noise. The algorithm uses the steepest descent method for the phase/magnitude estimation. Performances of tile CAFC algorithm are presented in comparison with those by the AFC algorithm based on computer simulations and experiments.

  • PDF

A Study of Sound Pressure Characteristics of Error Sensors by Position in Active Noise Barrier Development (능동형 방음벽 개발을 위한 에러센서 위치 연구)

  • Cha, Sang-Gon;Kim, Dong-Hwan;Troshinun, Andrey;Choi, Jang-Cheol;Shin, Eun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1756-1757
    • /
    • 2011
  • 본 논문에서는 FXLMS 알고리즘을 이용하여 3차원 폐공간(반무향실)에서의 순음(125Hz)을 이용하여 부 음원과 에러센서의 위치 변화에 따른 소음저감 정도를 분석하였으며, 이 결과를 바탕으로 능동형 방음벽의 구현의 기초자료로 활용하고자 하였다. 부음원(제어스피커, 이하 부음원)과 에러센서간 거리차는 0.5m, 1.5m, 2.5m를 대상으로 실험을 실시하였으며 그 중 거리차가 1.5m 지점의 경우, 125Hz부근에서는 최대 18.3dB, Overall(80Hz~200Hz)값은 18.2dB(A)의 소음저감 효과가 있는 것으로 나타나, 가장 효과적인 부음원과 에러센서간의 거리차인 것으로 평가되었다.