• Title/Summary/Keyword: 능동안테나

Search Result 206, Processing Time 0.025 seconds

The Phase Difference Measurement Module Development for Amplitude Modulated Range Measurement System (진폭 변조 거리 측정 시스템을 위한 정밀 위상차 측정부 개발)

  • Noh, Hyoung-Woo;Park, Jeong-Ho;Kang, Il-Heung;Choi, Mun-Gak;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • A amplitude modulation(AM) range measuring system utilizes the phase difference of the modulated envelope of the reflected signal to measure the distance. It is known that the AM system has a problem in accuracy due to antenna leakage signals and spurious reflection signals, but an AM range measurement system using an active reflector, which shifts the frequency bands, has been proposed in order to minimize the measurement errors due to spurious signals. In this paper, a new phase measurement module for the AM range measurement system, which enables to measure long distance with good accuracy, is proposed. The modulation frequency is alternatively selected between 8 and 1 MHz, and the measured distance range with this module is up to 150 m within 2 cm accuracy. A JK flip-flop circuit is used for higher phase accuracy, and an XOR circuit is used to cover long distance.

Analysis of Interferences into a Space Weather Observation Receiver in 2.8GHz Band (2.8GHz 대역 우주기상 관측 수신기에 미치는 간섭 분석)

  • Kang, Young-Heung
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.5
    • /
    • pp.350-357
    • /
    • 2022
  • With the recent prediction of 'Cycle 25', the importance of space weather research increases. Accordingly, the World Radiocommunication Conference (WRC)-23 has adopted Agenda Item 9.1a) and carried out sharing researches between active/passive space weather observation systems and existing services. Therefore, in this paper, in order to increase the precision of space weather environment data and secure the frequency spectrum for observation systems, the direct interference effect from the weather radar in Gosan, Jeju on the space weather observation receiver in Hallim, Jeju, and the indirect interference on the observation receiver by diffraction and scattering from the radar target have been analyzed. As a result, it can be known that the radar direction, the propagation direction diffracted and scattered from the target, and the Rradar Cross Section (RCS) of the radar target, the reception area of the space weather observation antenna, and the antenna off-boresight are important parameters for the interference effect analysis.

Morphological Differentiation of the Trap in Aquatic and Terrestrial Utricularia Species (서식환경에 따른 통발속(Utricularia) 포충낭의 형태 분화)

  • Lee, Kyoung-Lan;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.237-244
    • /
    • 2010
  • Utricularia forms small, but complex carnivorous trap along the stem either in water or in soil depending upon species. The shapes and sizes of the traps, appendages, and trichomes are known to differ among aquatic, terrestrial and epiphytic species. In the present study, the morphology and microstructure of the trap in aquatic Utricularia japonica and terrestrial U. livida were examined using light and electron microscopy. The aim of this study was to compare the characteristics of trap features between the aquatic and terrestrial species. The trap was found to be comprised of a thin walled bladder with numerous capitate trichomes, two-armed bifid and four-armed quadrifid glands in both species; however, the traps of the two species were different in size, and number and morphology of the trichomes and glands. Aquatic Utricularia was chlorenchymatous with chloroplasts distributed throughout the body, whereas the terrestrial species was translucent without plastids due to an adaptation to underground habitats. Furthermore, the former differed considerably in that the traps developed antenna and appendages around the entrance area. A peculiar trap entrance was also noted in U. livida, which exhibited radiating rows of various trichomes within funnel-shaped tissue. A large number of glandular trichomes covered the entrance area and door surface with four trigger hairs each in the aquatic form but only two in the terrestrial form. The glandular trichomes near the door secreted a large amount of mucilage that temporarily composed the velum in the U. japonica, however, it was not observed in the terrestrial species. All of the aforementioned features were highly related in their structure and function during carnivorous mechanism in Utricularia. The current findings provide important data for further comparison of the different life forms within Utricularia.

Subarray Channel Calibration and Performance Analysis for Digital Beam-Forming (디지털 빔 형성을 위한 부배열 채널 보정 및 성능 분석)

  • Jang, Sung-Hoon;Ahn, Chang-Soo;Kim, Dong-Hwan;Kim, Seon-Ju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.235-244
    • /
    • 2014
  • This paper describes the subarray channel configuration and calibration method for airborne AESA radar antenna. AESA radar demonstrator was designed and implemented for the digital beam-forming performance test of the 12 channel subarray structure. Magnitude and phase difference can be exist between the manufactured subarray channel. In this paper, calibration method for the subarray difference error was suggested. We measured digital monopulse slope in the subarray channel and verified the channel calibration effect. To verify the subarray channel operation, digital monopulse channel was compared with analog monopulse channel performance. AESA radar demonstrator was tested in the ground far field test range. Emulated single target was generated to test the detection and tracking performance of the demonstrator with the same waveform and search pattern. We verified that the detection and tracking performance of the 12 subarray digital monopulse channel was similar with the conventional analog monopulse channel. Also, ABF(Adaptive Beam-Forming) function for the sidelobe jammer was tested and effective operation was verified.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Evaluating of the Effectiveness of RTK Surveying Performance Based on Low-cost Multi-Channel GNSS Positioning Modules (다채널 저가 GNSS 측위 모듈기반 RTK 측량의 효용성 평가)

  • Kim, Chi-Hun;Oh, Seong-Jong;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.53-65
    • /
    • 2022
  • According to the advancement of the GNSS satellite positioning system, the module of hardware and operation software reflecting accuracy and economical efficiency is implemented in the user sector including the multi-channel GNSS receiver, the multi-frequency external antenna and the mobile app (App) base public positioning analysis software etc., and the multichannel GNSS RTK positioning of the active configuration method (DIY, Do it yourself) is possible according to the purpose of user. Especially, as the infrastructure of multi-GNSS satellite is expanded and the potential of expansion of utilization according to various modules is highlighted, interest in the utilization of multi-channel low-cost GNSS receiver module is gradually increasing. The purpose of this study is to review the multi-channel low-cost GNSS receivers that are appearing in the mass market in various forms and to analyze the utilization plan of the "address information facility investigation project" of the Ministry of Public Administration and Security by constructing the multi-channel low-cost GNSS positioning module based RTK survey system (hereinafter referred to as "multi-channel GNSS RTK module positioning system"). For this purpose, we constructed a low-cost "multi-channel GNSS RTK module positioning system" by combining related modules such as U-blox's F9P chipset, antenna, Ntrip transmission of GNSS observation data and RTK positioning analysis app through smartphone. Kinematic positioning was performed for circular trajectories, and static positioning was performed for address information facilities. The results of comparative analysis with the Static positioning performance of the geodetic receivers were obtained with 5 fixed points in the experimental site, and the good static surveying performance was obtained with the standard deviation of average ±1.2cm. In addition, the results of the test point for the outline of the circular structure in the orthogonal image composed of the drone image analysis and the Kinematic positioning trajectory of the low cost RTK GNSS receiver showed that the trajectory was very close to the standard deviation of average ±2.5cm. Especially, as a result of applying it to address information facilities, it was possible to verify the utility of spatial information construction at low cost compared to expensive commercial geodetic receivers, so it is expected that various utilization of "multi-channel GNSS RTK module positioning system"