• Title/Summary/Keyword: 누출

Search Result 1,815, Processing Time 0.037 seconds

Leakage Effect on the Exit Pressure in a Gas Pipeline (가스 파이프라인 내의 누출 현상이 출구 압력에 미치는 영향에 대한 연구)

  • Chang Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.27-33
    • /
    • 2006
  • This paper investigates leak effect on the outlet pressure at pipeline exit. A modified Weymouth equation(including inclination effect) was used for this study. To investigate leak effect, outlet pressure and ratio of outlet to inlet pressure were compared between no leak and leak conditions for horizontal, upward and downward flows, respectively. Then, effects of leak location as well as leak rate on the outlet pressure were also investigated for all pipeline inclinations.

  • PDF

가스정책(2) - 가스누출확인배관용밸브, 은폐배관 점검구 대체 가능

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.295
    • /
    • pp.93-95
    • /
    • 2015
  • 지난 2013년 7월 25일 도시가스사업법 시행규칙 개정에 따라 도시가스 은폐배관 설치 시 천정에 가스누출점검을 위한 점검구를 뚫거나 값비싼 다기능가스안전계량기를 설치해야 한다. 이에따라 수많은 민원이 발생하여 대한설비건설협회(이하 협회)는 실내 미관을 위해 점검구의 크기를 축소하고, 가스누출 점검을 위한 대체방법으로 다기능가스안전계량기 뿐만 아니라 가정에서 저렴하게 설치할 수 있는 가스누출확인배관용밸브 설치도 허용해 줄 것을 건의해 왔다. 협회 건의에 대해 가스기술기준위원회는 지난 1월 27일 질의회신을 통해 가스누출확인배관용밸브 설치 시 은폐배관의 가스누출이 탐지 가능하므로 가정 내에서 이 밸브를 설치할 경우 점검구를 뚫지 않아도 된다고 회신했다.

  • PDF

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter (스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발)

  • Jung-Hoon Kim;Jung-Suk Oh;Jin-Han Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.57-64
    • /
    • 2023
  • As the meter reading method of gas meters develops, smart gas meters capable of remote meter reading (leak checking meters and multi-function safety meters) are being used. These meters have a function to judge leakage by utilizing the flow rate and pressure data collected as an additional function. Leakage judgment function using flow rate data has valid cases in the actual field, but the pressure data-based leakage judgment standard is based on not only the pressure value change due to leakage but also various factors (pressure regulator pressure, connection with adjacent meters, usage of adjacent houses, location of meters, etc.). There is a problem with pressure magnitude changes (levels). In this paper, as a technique that can judge leaks by using pressure data collected from smart gas meters, it was developed through preprocessing of pressure data, criteria for pressure value ranges related to leaks, leak judgment techniques, and application case verification.

The 3-D Simulation of Electrophoresis Method in Leachate System for Repairing of Leaks in Waste Landfill Geomembrane Liner (폐기물 매립지 차수층 누출시 전기영동 복원을 위한 침출수 환경에서의 3차원 형상 모사 연구)

  • Han, Sang-Jae;Kim, Jong-Yun;Kim, Byung-Il;Kim, Soo-Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.17-25
    • /
    • 2010
  • Electrophoresis may offer a new technique to repair in service leaking geomembrane liner of municipal solid waste (MSW) impoundment. The method involves introducing a suspended clay particles, which are charged negatively, into the leakage in geomembrane liners by electrokinetic phenomena and formation of clay cake around leakage for prevention of leachate outflows. Therefore, the 3-dimensional leakage simulation experiments are conducted to evaluate the field applicability of sealing leaks of waste impoundment. In addition, the adequateness of optimum influence factors deduced from 1-dimensional experiments is evaluated. After the test, the total size (width, length) of clay cake formation around leak is increased with enlargement of leakage diameter and distance decrease detween anode and cathode.

EFFECT OF RESIN SEALANTS ON THE REDUCTION OF MICROLEAKAGE IN COMPOSITE RESTORATIONS (복합레진 수복물의 미세누출 감소를 위한 레진 전색제의 효과)

  • Cho Young-Gon;Kim Mun-Hong;Lee Myung-Goo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.282-289
    • /
    • 2006
  • The purpose of this study was to compare the ability of three resin surface sealants to prevent microleakage in Class V composite resin restorations. Forty Class V cavities with the occlusal margin in enamel and gingival margin in dentin were prepared on the buccal surfaces of sound extracted molars, and restored with composite resin. Restorations were randomly assigned into one of four equal groups (n = 10): a control group, without resin sealing, and three experimental groups in which margins were sealed with Fortify Plus, Biscover and Permaseal, respectively. Specimens were thermocycled, immersed in a 2% methylene blue solution for 4 hours, sectioned longitudinally, and observed the leakage at the occlusal and gingival margins. The result was analyzed using Kruskal-Wallis test, Mann-Whitney test and Wilcoxon signed rank test. In conclusion, the ability to reduce microleakage at occlusal margins was similar in all of three sealants. However at gingival margin, it depended on the type of used resin surface sealant. At gingival margin. control and Fortify Plus group showed statistically higher microleakage than PermaSeal group. and Fortify Plus group also showed higher microleakage than BisCover group (p < 0.05).

A Numerical Study on the CO2 Leakage Through the Fault During Offshore Carbon Sequestration (해양지중에 저장된 이산화탄소의 단층을 통한 누출 위험 평가에 관한 수치해석 연구)

  • Kang, Kwangu;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To mitigate the greenhouse gas emission, many carbon capture and storage projects are underway all over the world. In Korea, many studies focus on the storage of $CO_2$ in the offshore sediment. Assurance of safety is one of the most important issues in the geological storage of $CO_2$. Especially, the assessment of possibility of leakage and amount of leaked $CO_2$ is very crucial to analyze the safety of marine geological storage of $CO_2$. In this study, the leakage of injected $CO_2$ through fault was numerically studied. TOUGH2-MP ECO2N was used to simulate the subsurface behavior of injected $CO_2$. The storage site was 150 m thick saline aquifer located 825 m under the continental shelf. It was assumed that $CO_2$ leak was happened through the fault located 1,000 m away from the injection well. The injected $CO_2$ could migrate through the aquifer by both pressure difference driven by injection and buoyancy force. The enough pressure differences made it possible the $CO_2$ to migrate to the bottom of the fault. The $CO_2$ could be leaked to seabed through the fault due to the buoyancy force. Prior to leakage of the injected $CO_2$, the formation water leaked to seabed. When $CO_2$ reached the seabed, leakage of formation water stopped but the same amount of sea water starts to flow into the underground as the amount of leaked $CO_2$. To analyze the effect of injection rate on the leakage behavior, the injection rate of $CO_2$ was varied as 0.5, 0.75, and $1MtCO_2/year$. The starting times of leakage at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 11.3, 15.6 and 23.2 years after the injection, respectively. The leakage of $CO_2$ to the seabed continued for a period time after the end of $CO_2$ injection. The ratios of total leaked $CO_2$ to total injected $CO_2$ at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 19.5%, 11.5% and 2.8%, respectively.

A Study on the Improvement of Safety of Unloading Site by Comparison of Hydrogen Fluoride Leakage Accident (불화수소 누출사고 비교를 통한 하역작업장의 안전성 향상방안에 관한 연구)

  • Woo, Jongwoon;Shin, Changsub
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • The purpose of this study is to assess quantitatively the amount of leaks and the extent of dispersion in case of a leak at a hydrogen fluoride tank container unloading station, and to suggest a safety improvement plan to prevent recurrence of similar accidents. In 2012, Company H leaks 8 tonnes of tank containers with a maximum storage capacity of 18 Ton, causing it to become a social issue. As a result of calculation using Gaussian plume model, the concentration was estimated to be more than 20ppm from the leak point to 1,321 m radius. The leakage of hydrogen fluoride from the company R in 2014 was estimated to be 11.02 kg, of which 2.9 kg was treated by the scrubber. As a result of calculation using Gaussian plum model, the damage range with a concentration of 20ppm or more from the leak source was estimated to be 69 m in radius. As a result of comparing the above two accidents, it was found that the leakage amount was about 987 times different and the damaged site was more than 19 times different. Therefore, it was concluded that it was necessary to control the wearing of the protective equipment, the enclosure of the unloading site, the installation of the scrubber, and the emergency training to avoid the accidental leakage of a hydrogen fluoride from the unloading site.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.