• Title/Summary/Keyword: 누적선량

Search Result 83, Processing Time 0.017 seconds

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF

Early Bowel Complications Following Radiotherapy of Uterine Cervi)( Carcinoma (자궁경부암의 방사선치료 후 급성 장관 합병증)

  • Kim, Won-Dong
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.129-135
    • /
    • 1999
  • Purpose : This study evaluated early bowel complications in cervix cancer patients, following external radiotherapy (ERT and high dose rate intracavitary radiation (HDR ICR). Factors affecting the risk of developing early bowel complications and its incidence are analyzed and discussed Materials and Methods : The study is the retrospective review of 66 patients who received radiotherapy at Chungbuk National University Hospital from April 1994 to December 1998. The patients underwent 41.4 or 50.4 Gy ERT according to FIGO stage and tumor size, then A point dose was boosted to 71.4 or 74.4 Gy using a remotely controlled afterloading Buchler HDR ICR. The EORTC/RTOG morbidity criteria were used to grade early bowel complications, which are valid from day 1, the commencement of therapy, through day 90. The actuarial incidence, severity of complications were investigated and clinical pretreatment factors relevant to complications were found through univariate (Wilcoxon) and multivariate (Cox proportional hazard model) analysis. Results : Of the 66 patients, 30 patients (46$\%$) developed early bowel complications; 25 patients (38$\%$) with grade 1 or 2, 4 patients (0$\%$) with grade 3 and 1 patient (2$\%$) with grade 4. The complications usually began to occur 3 weeks after the commencement of radiotherapy. The actuarial incidence of early bowel complications was 41$\%$ at 10 weeks. The early bowel complications were associated significantly with an old age and a history of previous abdomino-pelvic surgery. All three patients who had a protracted overall treatment time (about 2 weeks) due to severe bowel complication, suffered from pelvic recurrences. Conclusion : Forty six percent of patients experienced early bowel complications, most of which were grade 1 or 2 and relieved spontaneously or by medication. The patients with an old age or a previous surgery have a high probability of early complications and they may be less compliant with planned radiotherapy. So more careful precaution is necessary for these patients.

  • PDF

A Study on the Preservation of Citrus Mandarin by Irradiation (방사선조사(放射線照射)에 의(依)한 감귤(柑橘) 저장(貯藏)에 관(關)한 연구(硏究))

  • Chung, Chang Cho;Kim, Jai Ha;Kim, Soo Hyun;Cho, Han Ok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.12 no.2
    • /
    • pp.116-121
    • /
    • 1983
  • A study was conducted to evaluate the effect of $^{60}CO-{\gamma}$ irradiation on the preservation on Satauma mandarin in Cheju Island. Four varieties (S. m. early, S. m. Komezawa, S. m. Hayashi and S. m. Aoshima) were irradiated using 10,000Ci, $^{60}CO-{\gamma}$ ray with dosages of 0, 50, 100 and 150Krad. During 92 days of storage the effects of irradiation on mandarin porperties were as follows: At the end of storage period the accumulated fruit rotting percentage were S. m. Komezawa($T_2$);74.32%, S. m. early($T_1$);69.67%, S. m. Aoshima($T_4$);64.33% and S. m. Hayashi ($T_3$);61.79%. The rottings steadily increased from the early stage of storage and rapid spoilage continued after 59 days of irradiation. A high corelation existed between fruit rotting and varieties ($T_3$;Y=0.78x-15.30, $T_4$;Y=0.79x-12.29, $T_1$;Y=0.93x-9.01 and $T_2$;Y=0.79x-13.49) High dosages(100 and 150 Krad)improved fruit preservation during the mid storage stage. However 76 days after high dose irradiation there was no significant difference a rotting between irradiated fruit and the control. Irradiation decreased acidity of fruit during storage (p<0.01). The mean acidities of examined varieties were $T_1$;1.01%, $T_3$;1.01%, $T_4$;0.84% and $T_2$;0.77%. A significant differences were observed in acidity between varieties and dosages(P<0.01) With one exception in all treatments. the increase in free and total sugar content was not statestically significant. The exception was the 50 Krad treatment where the total sugar content decreased. $T_1$ and $T_4$ showed slightly higher value of than Brix $T_2$ and $T_3$, and were significantly(P<0.01) decreased by higher dosage. The ascorbic acid content in all treatments decreased with length of storage and also decreased significantly with a higher dosage.

  • PDF