• Title/Summary/Keyword: 누수 시험

Search Result 147, Processing Time 0.026 seconds

Improvement of existing drainage system for leakage treatment in exiting underground structures (운영중인 지하구조물의 누수처리를 위한 유도배수공법의 개선)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.669-683
    • /
    • 2017
  • The objective of this study is to propose a modification of the previously proposed drainage system for catching the partial leakage of underground concrete structures. Two techniques were proposed for applying the drainage system only to the leaking parts. One was for conveying leaking groundwater to the collection point in the drainage system and the other was for conveying the collected groundwater to the primary drainage system of the underground concrete structure. Four waterproofing materials for conveying leaking groundwater to the catchment point of the drainage system, Durkflex made of porous rubber material, KE-45 silicone adhesive with super strong adhesion, Hotty-gel made of polymeric materials and general silicone adhesive were evaluated for waterproofing performance. Hotty-gel only showed perfect waterproof performance and the other three waterproof materials leaked. The modified drainage system with Hotty-gel and drainage pipe with fixed saddle to convey the leaking groundwater from the catchment point to the primary drainage system were tested on the concrete retaining wall. The waterproof performance and the drainage performance were evaluated by injecting 1,000 ml of water in the back of the modified drainage system at the 7-day, 14-day, 21-day, 28-day, 2-month and 3-month. There was no problem in waterproof performance and drainage performance of the modified drainage system during 3 months. In order to evaluate the construction period and construction cost of the modified drainage system, it was compared with the existing leaching repair method in surface cleaning stage, leakage treatment stage, and protective barrier stage. Total construction period and construction cost were compared in considering the contents of work, repair material, construction equipment, working time, and total number of workers. As a result of comparing and analyzing in each construction stage, it was concluded that the modified drainage system could save construction period and construction cost compared to the existing leaching repair method.

Effect of freezing and thawing on the drainage system for leakage treatment (유도배수공법에서 동결융해의 영향)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.1059-1075
    • /
    • 2017
  • The objective of this study was to evaluate the freezing and thawing resistance of the existing drainage system for leakage treatment of underground concrete structures operating in cold regions. The freezing and thawing test was conducted on 4 types of drainage system specimens to evaluate the freezing and thawing resistance of the drainage system. The freezing and thawing resistance was evaluated on 4 types of Hotty-gel, as a waterproofing material, connection methods and on two methods to fix the drainage board with Hotty-gel on the surface of cement concrete specimen. One cycle of the freeze-thaw testing was 48 hours (24 hours of freezing and 24 hours of thawing), and the temperatures of freezing and thawing were at $-18^{\circ}C$ and $10^{\circ}C$, respectively. Among the 4 types of Hotty-gel connection methods, leakage occurred after 28 cycles (8 weeks) of freeze-thawing only in the Hotty-gel connection method with the 'V' groove applied to the corner of the drainage board. No leakage occurred in the 3 types of Hotty-gel connection methods. In two fixing methods, leakage occurred in the method of fixing the drainage board on the cement concrete specimen using the washer, screw and plastic wall plug. Leakage occurred at one point after 10 cycles (3 weeks) of freezing and thawing. After 28 cycles (8 weeks) of freezing and thawing, leakage point increased to 5 points. As time passed, the leak point was not increased, but the amount of leakage was increased at each leak point. The Hotty-gel connection method with cross-sectional diagonal shape was evaluated to be the highest in the production efficiency considering the production time and manufacturing method of the Hotty-gel connection shape. In the construction efficiency considering the construction time and construction method, the fixing method of air nailer, fixed nail and washer was superior to that of the washer, screw and plastic wall plug.

A Study on Improving Estimation of Recurrence Rate of Public Water -Jungnangcheon Watershed- (생활용수 회귀수량 산정방법의 개선연구 -중랑천 유역을 대상으로-)

  • Jung, Chung Gil;Ahn, So Ra;Joh, Hyung Kyung;Kim, Seong Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.509-509
    • /
    • 2015
  • 물 수요관리측면에 대한 정책을 수립하기 위해서는 현재 또는 장래에 대한 용수수급의 정확한 이해를 필요로 한다. 이를 위해서는 용수 수요량 및 공급량뿐만 아니라 여러 산정요소를 필요로 하는데, 그 중 회귀수량은 물이 이용되고 다시 하천으로 회귀되어 이용될 가능성이 있는 수량으로 정의되며, 용수수급 및 용수절약 측면에서 회귀 수량은 중요한 요소라 할 수 있다. 회귀수량 조사는 유역조사 사업 이래, 10년간 생?공용수를 중심으로 미시적, 거시적으로 조사를 시행하였으나, 측정 자료의 신뢰도, 조사방법 및 지점선정 등의 문제로 인하여 조사 성과의 활용성이 매우 낮은 실정이다. 수자원장기종합계획등에서는 수자원관련 계획 수립시 생?공용수의 회귀율을 65 %로 적용하고 있으나, 이는 1970년대 말의 사회적 여건 및 경제적 상황이 반연된 결과로 현재 상황에 적용되기 곤란하다. 따라서, 현재 실정에 맞는 회귀율 산정은 반드시 필요하게 된다. 본 연구에서는 기존 생활용수 회귀수량 산정 연구 한계를 보완하고 유역조사 시행을 위한 개선된 회귀수량을 산정하고자 한다. 본 연구는 서울시 중랑물재생센터 처리구역을 기반으로 중랑천유역을 시험유역으로 선정하였다. 기존 회귀수량 산정방법을 개선하기 위해 시험유역 회귀수량 산정을 위한 가용 자료 분석 및 용수흐름 네트워크 공간분석을 추가로 진행하였다. 가용자료로 시험 유역내 상수공급자료(정수장 공급량, 상수계통도, 유수 및 누수율), 하수처리자료(하수처리구역도, 하수처리계통도, 유입량 및 방류량) 및 기상자료(기상청 지점 및 AWS 강우자료)를 구축하였고 각각의 상수계통도 및 하수처리계통도로부터 용수 흐름 네트워크망을 구축하였다. 상수공급자료로부터 상수계통도 공급지역을 구분하여 월별 유수율에 따른 월별 실 공급량을 산정하였다. 하수처리자료로부터 시험유역에서의 월별하수처리 유입량 및 방류량을 산정하였다. 최종적으로 회귀율(하수처리 방류량/실 공급량)을 산정한 결과 연평균 회귀율은 각각 93.97 %(2011년), 95.02%(2012년)로 과잉 추정 되었으며 7 ~ 9월의 회귀율은 110 ~ 120 %로 유입량을 초과하였다. 이는, 하수처리로 유입되는 유입량의 하수관거는 합류식으로 구축되어 7 ~ 9월에 많은 양의 강우량이 우수관을 통해 하수처리장으로 이송되어 생활용수 이외에 자연적인 공급량으로 인한 것으로 분석되었다. 따라서, 월별 회귀율 산정을 위해서는 불투수층에서의 면적강우량(mm)을 유입량(m3/s)으로 환산된 값을 고려하여 회귀율을 재산정하였다. 그 결과 연평균 회귀율은 각각 78.27 %(2011년), 77.58 %(2012년)로 나타났다.각각의 월별 회귀율도 매우 유사하게 나타났으며 과거 관용적으로 사용된 65 % 회귀율보다 약 12 ~ 13%로 증가하였으며 이는, 하수처리시설 구축 및 처리효율의 증가와 상수처리시설의 관로시설의 개량으로 인한 유수율 및 누수율 감소로 회귀율이 증가한 것으로 판단된다.

  • PDF

An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam (흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Suh, Baek-Soo;Kim, Joong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • Both multi-channel temperature monitoring and geophysical electric survey were performed together for an embankment to assess the leakage zone. Temperature variation according to space and time on the inner parts of engineering constructions (e.g.: dam and slope) can be basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation (e.g.: cracks and defects) could be generated by various factors. Seepage or leakage of water through the cracks or defects in old dams will directly cause temperature anomaly. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For that matter, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body. Geophysical data by electrical method are also added to help interpret data.

A Study on the Performance Evaluation of Water(wash out) Resistance of 5-Type Repair Materials in Water Leakage of Underground Concrete Structures (지하 콘크리트 구조물 누수부위에 시공되는 5계열 보수재료의 유실 저항 성능 평가 연구)

  • Kim, Soo-Yeon;Yoo, Jae-Yong;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.61-68
    • /
    • 2020
  • In this study, the international standard ISO TS 16774 Part 3 Test Method for Water (wash out) Resistance and KS F 4935 「Sealant Injection type for water leakage maintenance of adhesive flexible rubber asphalt series」, which are standardized as a quality control method of injection type repair materials used for water leakage cracks in underground concrete structures, are currently used in Korea. As a result, considering the performance criteria of "mass change rate -0.1%" stipulated in KS F 4935, the remaining 13 types repair materials, excluding RG-2 of synthetic rubber and UG-1 of urethane, need to be reviewed for stabilization of the loss resistance due to the flow of ground water. The results of this study are determined to be available as a basic indicator for the selection of repair materials used for cracks in concrete structures. In addition, it is expected that the results of this study can be utilized as reference data that can be reflected in the improvement of the quality of repair materials that will be researched and developed later.

A Study Of Practical For Eco-Grouting Materials (친환경 그라우팅 재료를 통한 현장 적용성 연구)

  • Moon, Kim-Hak;Jang, Kyung-Jun;Hur, Won;Hur, Hyung-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1253-1257
    • /
    • 2010
  • 그라우팅은 건설공사에서 지반의 갈라진 틈이나 공동, 공극 등에 적절한 충전재를 압력을 이용하여 주입하는 것으로, 굴착공사 시 누수방지와 불안정한 지반의 보강을 위하여 광범위하게 사용되고 있다. 가장 많이 사용되고 있는 그라우팅 주입재의 재료로는 물유리계를 주재료로 사용하는 약액주입공법이 많이 사용되어지고 있다. 기존의 물유리계 재료를 사용할 경우 발생하는 용출현상 및 강도저하를 보완하기 위하여 가소성을 부과한 무기질계 재료ECG(Eco Clean Grouting)를 사용하여, 강도 및 내구성이 우수하고 주입재의 용출 현상이 발생하지 않아 환경오염 문제가 거의 없는 영구적인 차수 및 보강에 적합한지와 친환경적 특성을 확인한다. 본 연구는 가소성 무기질계 재료인 ECG(Eco Clean Grouting)재료를 사용하여 현재 많이 사용되는 재료인 물유리계 재료로 일축압축강도, 체적변화, 내구성 평가, 투수시험, 어독성 시험, 용탈시험등을 수행하여 비교 분석 하였다. 일축압축 시험결과 재령 28일 강도는 ECG가 물유리재료에 비해 크게 발현되었고, 내화학성시험 결과 ECG의 길이변화율이 거의 없는 것으로 내화학성에서 강점을 보였다.

  • PDF

Verification of Reinforcement with Grouting Materials in a Small Scale Reservoir Dike using Surface and Borehole Electrical Resistivity survey (지표 및 시추공 전기비저항 탐사를 중심으로)

  • Song, Sung-Ho;Yong, Hwan-Ho;Kim, Yang-Bin
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.239-245
    • /
    • 2009
  • To verify the reinforcing effect of grouting materials composed of colloid cement and ordinary portland cement on the water leakage region in a small scale dike, we performed a tubecasing method and applied surface electrical resistivity survey including electrical resistivity tomography (ERT) to find resistivity variation before and after grouting. Hydraulic conductivities after grouting show 10 times lower than those of before grouting. These variation indicates that the cement grout blocks the leakage pathway effectively. As the results of dipole-dipole resistivity survey along the dike, resistivity distribution after grouting did not represent noticeable spatial variation in time. Resistivity monitoring results at the dike with vertical electrical sounding (VES) showed that the region of decreasing apparent resistivity was occupied by the grout after grouting. Predicted resistivities from the inversion of ERT data well matched with results of VES at the same regions. From the ERT using check holes to inspect the effect of grouting, we could find that the ERT is quite effective to identify spatially the grout region in a dike.

균열암반에서의 양수시험자료 해석과 일반화 방사상 유동모델의 적용성 연구

  • 성현정;김용제;우남칠;이철우;김구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.493-496
    • /
    • 2003
  • 이 연구는 우리나라 균열암반 대수층의 수리적 특성을 해석ㆍ평가하기 위하여 양수시험 해석해(Theis, 1935; Cooper-Jacob, 1946; Papadopulos-Cooper, 1967; Hantush, 1962a,b; Moench, 1985; Hantush-Jacob, 1955) 및 일반화 방사상 유동 모델을 이용하여 균열암반 대수층(화강암, 화산암, 변성암, 백악기퇴적암, 제3기 퇴적암에 굴착된 100개 조사공)에서 수행되어진 양수시험으로부터 얻은 122개의 양수시험자료(수위강하 자료)를 분석하였다. AQTESOLV 전산프로그램을 이용한 양수시험자료 분석에 의하면, 122개 자료중 86개(71%)의 자료들이 이 연구에 사용된 해석해와 일치하며, 양수시험자료 해석해 중에 누수(leaky) 및 경계조건(boundary condition)을 고려한 해석해들이 53개(43%)로 가장 많이 나타났다. 그러므로, 양수시험자료의 해석은 균열암반 대수층의 수리지질학적 특성에 적합한 개념모델의 설정이 중요하다. 일반화 방사상 유동(GRF)모델을 적용해보면, 122개의 자료중 77개(63%)의 자료들이 Barker(1988)의 표준곡선에 의한 차원(1.1차원-2.9차원)을 보여준다. 이중 44.2%에 해당하는 39개 자료가 1.1차원과 1.9차원 사이의 분할 유동차원을 보여주는 반면에 26개(6.5%)만이 Theis 이론에 맞는 2차원의 방사상 흐름을 보여주며, 38개(49.3%)는 2.1차원에서 2.9차원에 속한다. 따라서 우리나라 균열암반 대수층에서 지하수 유동은 대부분 분할차원의 유동을 보여주는 것으로 평가된다.

  • PDF

Design of POGO Supporession Device Performance Test System (POGO 억제장치 성능 시험기 설계)

  • Lee, Han-Ju;Kim, Ji-Hun;Jeong, Dong-Ho;O, Seung-Hyeop
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.181-187
    • /
    • 2006
  • The present study deals with the experimental facility for PSD (POGO Suppression Device) performance test systems. Basically there are two methods to pulsate the system; whole-feeding-system pulsation and working-fluid pulsation. The latter method adopts either a piston-type pulsator or a restrict-type pulsator. The working-fluid pulsation using a restrict-type pulsator was considered to be the most appropriate experimental system to study the effects of the primary parameters, and a practical design of the system was proposed. Also, the experimental facility adopts the ball valve type pulsator considering the leak problem of the plate type pulsator.

  • PDF

하천 바닥 퇴적층의 투수성시험과 누수계수 추정

  • Ha Gyu-Cheol;Go Dong-Chan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.371-374
    • /
    • 2006
  • To quantify the hydraulic connection between river and aquifer, riverbed leakance values are required to be estimated. Silt, clay, and organic materials are often deposited in rivers resulting in the streambed having a lower hydraulic conductivity than the underlying alluvial aquifer The riverbed hydraulic conductivities are measured through vertical and oblique permeameter test. Anisotropic and heterogeneous properties of riverbed hydraulic conductivity were identified. Grain size analysis and flood wave response technique were checked along with the permeameter test for the riverbed hydraulic conductivity.

  • PDF