• Title/Summary/Keyword: 누수층

Search Result 61, Processing Time 0.024 seconds

Parameters Estimation and Analysis for Leaky Aquifer System (누수대수층에 대한 수리상수 추정과 해석)

  • 김민환
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.3
    • /
    • pp.123-128
    • /
    • 1998
  • Leaky aquifer (two-aquifer) system in this study consist of an upper unconfined and a lower confined aquifer with a leaky layer between them. It is assumed that water is withdrawn from the confined aquifer of the aquifer system, the upper unconfined aquifer will be affected by the leaky aquifer separating the upper and lower aquifer. In order to analyze the leaky aquifer, the determination of hydraulic parameters is needed. In this paper, hydraulic parameters are suggested by improved SM (slope-matching) method. To know variation of groundwater head in leaky aquifer systems, an numerical scheme is made using the finite difference method. To verify the numerical scheme, its solution is compared to analytical one. The solution of them agrees well in one-dimensional system at steady-state condition. And heads of groundwader are computed upper and lower aquifer in two-dimensional system.

  • PDF

Analysis of Stream Depletion Rate by Groundwater Abstraction in Leaky Aquifer (누수대수층 지하수 양수에 따른 하천수 감소율 거동 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.1001-1008
    • /
    • 2017
  • This study was to evaluate the stream depletion rate from groundwater pumping with varying stream-well distance, aquifer transmissivity, storage coefficient, leakage coefficient, streambed hydraulic conductance using the Zlotnik and Tartakovsky analytical solution which considers a two-layer leaky aquifer-stream-well system. For the hydraulic conditions applied in this study, the streambed hydraulic conductance and the aquitard leakage coefficient were assessed to have a dominant influence on the stream depletion rate. In order to evaluate the applicability of Zlotnik and Tartakovsky analytical solution ignoring the change in the drawdown in the lower aquifer and applying the fixed head boundary condition, the solution was compared with Hunt analytical solution derived from the more practical conditions simultaneously taking into account the drawdown changes in the upper and lower aquifers. As a result, the Zlotnik and Tartakovsky analytical solution is suitable for predicting short-term effects of less than one year in the pumping period, and when the stream depletion factor (SDF) is greater than 2,500 days, or when the product of the leakage coefficient and the stream-well distance is less than 10 cm/s.

Analyzing Leakage Defect Types in Educational Facilities and Deriving Key Management Strategies Using the FTA Method (FTA기법을 이용한 교육시설 누수 하자 유형 분석 및 주요 원인 관리방안 )

  • Jung, Daegyo;Park, Hyunjung;Lee, Dongyeop;Kim, Daeyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2024
  • In recent years, the construction industry has diligently focused on improving the quality and safety of buildings through smart technologies. However, there is a growing trend of leakage defects, especially in educational facilities, due to aging. The objective of this study is to analyze the causes of these defects in educational environments using the Fault Tree Analysis (FTA) technique and propose preventive measures based on the findings. The FTA technique is explained through a review of domestic literature, and data from the Educational Support Center from 2019 to 2021 are examined to identify major defects. The construction of the Fault Tree (FT) for leakage defects resulted in the identification of 12 basic events. Subsequently, a comprehensive understanding of the causes of leakage is achieved through FTA analysis, leading to the identification of the primary causes of defects. Leakage defects accounted for 46.8% of all reported issues in educational facilities, with roof (ceiling) leaks being the most common problem. FTA analysis revealed that poor substrate treatment was the main cause of roof (ceiling) leaks, which could be attributed to cracks in the waterproof layer, joint cracks, and microvoids in the waterproof layer. The primary achievement of this research is to provide essential data for preventing leakage defects in educational facilities and developing preventive measures through the FTA technique. These results are expected to significantly enhance the management of educational facilities and the prevention of leakage issues.

Hydrologic Cycle Analysis of Cheonggye-cheon Watershed Considering Subway, Groundwater Pumping and Leakage Effects (지하철 노선 지하수 양수량 및 상수도 노선, 누수량을 고려한 청계천 유역 물순환 해석)

  • Noh, Seong-Jin;Kim, Hyeon-Jun;Jang, Cheol-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.174-179
    • /
    • 2006
  • 본 연구에서는 지하철 노선, 지하수 양수량 및 상수도 누수량 등 도시유역에서 물순환에 큰 영향을 미치는 인공적 요소들을 분포형 수문모형에 반영하여 물순환을 모의하였다. 분포형 수문모형으로는 일본토목연구소에서 개발된 WEP 모형을 사용하였다. 입력자료 구축시 지하철 노선을 따라서 제1투수층, 제1난투수층, 제2투수층의 투수계수를 낮게 설정하여 지하철 노선의 영향을 반영하였으며, 지하철역 및 구별 지하수 양수량, 상수도 누수량을 모형의 입력자료로 구축하였다. 모의결과를 서울시 지하수관측공의 실측 자료와 비교하여 양호한 결과를 얻을 수 있었으며, 유역 스케일에서의 지하수위 분포양상을 모의할 수 있었다. 지하철 노선, 지하수 양수량, 상수도 누수량 등을 고려, 미고려시를 별도로 모의하여 각각 요소가 물순환에 미치는 개별적 종합적 영향에 대해 평가하였다.

  • PDF

An Analysis of Groundwater Flow in the Multi-aquifer System (다층-대수층 시스템의 지하수 해석)

  • 김민환;전일권;정재성
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.10-16
    • /
    • 2002
  • The multi-aquifer system separated by semipervious leaky beds was analyzed. The finite difference scheme of the Crank-Nicolson method is applied to obtain the solution for this system. The solution of this scheme was compared with the analytical solution for two-layer aquifer systems with one-dimensional steady state. The results showed a good agreement between analytical and numerical solution for two-layer aquifer systems. So, the numerical scheme can be extended to multi-aquifer system. When the pumping is tried for single or multi aquifer, the computation of the groundwater heads was possible for each aquifer in the multi-aquifer with two-dimensional system. So, it might be helpful for the effective groundwater management.

Determination of Aquifer Parameters by the Improved Slope-Matching Method (개선된 SM(Slope-Matching) 방법에 의한 대수층의 특성변수 결정)

  • 김민환;오종민;전일권
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.73-81
    • /
    • 2001
  • With the development of industry and standard of living, the quantity of groundwater consumption has been increasing. For the analysis of groundwater, to determine the hydraulic parameters of aquifer is very important. Various numerical methods have been developed to solve aquifer tests and eliminate the subjectivity of traditional graphical type curve methods. The slope-matching method, which matches the slope of the Theis type curve to the slope of the field data, can be used to numerically solve pump tests for both leaky and nonleaky aquifers. A FORTRAN program on based slope-matching method was developed to obtain the transmissivity, storage coefficient, and leaky factor from pumping test data automatically. Results derived from published data show that the improved slope-matching method gives parameters close to the ones derived by the slope-matching method.

  • PDF

Analysis of Soil Vacuum Extraction using Analytical Solution of Groundwater Flow (지하수 흐름의 해석해를 이용한 토양진공추출 해석)

  • Kim, Min-Hwan;Lee, Hak;Han, Dong-Jin
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.139-145
    • /
    • 2009
  • An analytical solution of groundwater flow is applied to design soil vacuum extraction for removing volatile organic compounds from the unsaturation zone. The governing equation of gas or vapor flow in porous media is nonlinear in that gas density depends on gas pressure. A linear equation suggested by researcher is similar to that of groundwater flow. The pressure drawdowns of confined and leaky aqufiers are calculated using Massmann's field data, and the pressure drawdowns are compared. A solution of Theis equation calculated by Massmann is modified using GASSOLVE9 program in this paper. The pressure drawdown using Hantush's analytical solution for leaky aquifer also compared to that of Massmann. Hantush's analytical solution gives good approximations to pressure drawdown.

Evaluating Applicability of Hunt's Analytical Solution for Groundwater Pumping from a Leaky Aquifer (누수대수층 지하수 양수에 관한 Hunt 해석해의 적용성 평가)

  • Lee, Jeongwoo;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.555-561
    • /
    • 2020
  • In this study, the applicability of Hunt's analytical solution for a two-layered leaky aquifer system, which was developed to estimate stream depletion due to the groundwater pumping of the upper shallow aquifer, was evaluated. The 5-year averaged stream depletions were estimated using Hunt's analytical solution for various combinations of hydraulic characteristic values such as transmissivity, storage coefficient of the two aquifers, interlayer leakage coefficient, stream-well distance, hydraulic conductivity of the streambed, and stream width. Through comparison with the numerical solution accurately simulated with a MODFLOW groundwater flow model, the analytical solution derived by regarding the stream width as a point was evaluated. It was found that the error in the stream depletion calculated by the analytical solution can be reduced to less than 0.05 when the stream-well distance is greater than the stream width or when the stream depletion factor (SDF) is more than about 3,000 days. In addition, when the streambed hydraulic conductivity is less than 1 m/d, the hydraulic diffusion coefficient of the lower aquifer layer is less than 100 ㎡/d, the hydraulic diffusion coefficient ratio of the upper and lower aquifer layers is 5 or more, and the leakage coefficient between the layers is less than 0.0004 m/d, the overall analytical solutions were overestimated compared with the numerical solutions.

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

양수시험분석에 의한 제주도 화산암 대수층의 수리적 특성

  • 우윤정;함세영;정재열;이상선;장차연;박윤석;김봉상
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.292-295
    • /
    • 2003
  • 제주도 전역의 88개소에서 측정한 양수시험자료를 분석하여 투수량계수를 산출하였으며, 투수량계수계수와 비양수량의 관계식을 산출하였다. 제주도의 화산암 대수층은 대체로 투수성이 크고 대수층의 상.하부로부터 상당량의 지하수가 공급되므로 누수피압대수층이 적합한 모델로 판단된다. 투수량계수는 0.405~1038.52m$^2$/d로서 넓은 범위에 걸쳐서 분포하며 이는 제주도 화산 암의 투수성이 지역에 따라 다양하다는 것을 의미한다. 비양수량(Q/s)-투수량계수(T) 관계식은 T = 0.582(Q/s)$^{0.974}$ 로 계산되었으며, 이 관계식은 지역적으로 투수량계수 산출이 불가능할 경우에 비양수량만으로 투수량계수를 추정하는데 이용될 수 있다.

  • PDF