• Title/Summary/Keyword: 누수저항

Search Result 79, Processing Time 0.022 seconds

Verification of Reinforcement with Grouting Materials in Reservoir Dike using Electrical Resistivity Tomography (전기비저항 토모그래피를 이용한 저수지 제체 그라우팅 효과 검증)

  • Song, Sung-Ho;Yong, Hwan-Ho;Lee, Gyu-Sang;Woo, Myung-Ha
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.73-78
    • /
    • 2006
  • To verify reinforcing effect of grouting materials on the water leakage region in dike, we performed various hydraulic test and we also applied electric resistivity survey including electrical resistivity tomography(ERT) to see resistivity variation before and after grouting. As the results of dipole-dipole array survey along dike, resistivity distribution after grouting was without noticeable spatial variation. Long term resistivity monitoring results at dike with Schlumberger array electric resistivity survey showed that the decreasing region of apparent resistivity and one dimensional inversion results were the occupied region by grout after grouting. From the ERT using check holes to inspect the effect of grouting, we could find that the ERT is quite effective to evaluate spatially grout region in dike.

  • PDF

A Experimental Study on the Performance Test of Water Leakage Repair Materials for Water Expansion Acrylic Resin (아크릴 수지계 수팽창성 누수보수재의 재료적 성능평가에 관한 실험적 연구)

  • Hong Chae Han;Kim Su-Ryon;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.51-56
    • /
    • 2005
  • It does not find for solution by limitation of technological mechanism of existent of leakage maintenance material. So, it is paid for huge expense because continuous repeat maintenance work is consisting. Furthermore, it is indicated by big problem in construction work that is constructed by field experience that thing by definite and systematic theory is not with proper performance test and analysis up to now. Therefore, wish to measure physical performance change by various environment condition maintenance of structure and performance construction work aspect in that apply to water leakage maintenance material using of acrylic resin system water expansion, leakage maintenance material in this research, and present suitable form of construction work under these environment. also, wish to ready diversified remedy by oversea market opening.

  • PDF

Monitoring of grout material injected under a reservoir using electrical and electromagnetic surveys (전기비저항 및 전자탐사를 이용한 저수지 하부에 주입된 그라우트 재료의 모니터링)

  • Suzuki, Koichi;Oyama, Takahiro;Kawashima, Fumiharu;Tsukada, Tomoyuki;Jyomori, Akira
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • In order to reduce leakage from a reservoir, a large amount of cement milk (grout) was injected from boreholes drilled around the shores of the reservoir, and monitored to establish the infiltration of cement milk into the bedrock under the reservoir. From laboratory tests using rock core samples, it was revealed that the resistivity of cement milk is much lower than that of the groundwater at this location. Therefore, it was expected that the resistivity of the zones filled with cement milk would be significantly reduced. Geophysical surveys are expected to be suitable methods to check the effectiveness of grouting in improving the water-retaining performance of a reservoir. DC electrical surveys (seven in total) and two Controlled Source Audio-frequency Magneto-Telluric (CSAMT) surveys were conducted along survey lines in the reservoir to monitor the infiltration of cement milk during the grouting. Extremely low resistivity zones ($10\;{\Omega}m$ or less) were observed in resistivity sections obtained by 2D inversion. The zones are inferred to be fractured zones filled with cement milk. In sections showing the rate of change of resistivity, three zones that showed significant change showed gradual expansion to deeper parts as the grouting progressed. These zones correspond to highly permeable zones detected by Lugeon tests at grout boreholes. We have confirmed that it is possible to measure the resistivity change by DC electrical and CSAMT surveys from the surface of the reservoir. It seems that such monitoring results could be reflected in future grouting plans.

The Study on the New Renewal Methods for Rehabilitation of Deteriorated Sewerage by Chemical Attacks (화학침식에 의해 열화된 하수관로 갱생 공법에 관한 연구)

  • Lee, Hee Won
    • The magazine of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.38-52
    • /
    • 2014
  • 도시주민생활에 없어서는 안 될 주요한 사회간접자본시설인 하수도, 하수도처리시설 등의 콘크리트 구조물에 대한 부식열화는 현재 세계 각국에서 급속히 진행되고 있다. 콘크리트 구조물은 반영구적인 것으로 인식하고 있다. 그러나 각종 열화 인자에 의해 구조물의 사용수명은 급속히 단축된다. 하수시설 내에서는 황산이외에도 다양한 염류에 의하여 콘크리트구조물이 부식될 가능성이 있지만 황산에 의한 부식이 가장 대상범위가 넓고 부식속도가 빠르기 때문에 부식현상이 발견되면 급속하고 적절한 대응조치가 필요하다. 열화예측결과 및 구조물의 공용연수를 감안한 신뢰성이 높은 공법의 도입이 필요하며 이러한 조건에 적합한 유기재료와 무기재료의 복합 특성을 발휘하는 갱생공법에 사용되는 주요 소재의 실험적 특성에 관하여 고찰하였다. 그 결과 경질염화비닐(이하 프로파일)은 내외수압 저항성에서 3분간 $1kgf/cm^2$의 압력에도 누수 및 압력의 이동이 없었으며 약품침지에 따른 중량변화량이 $0.2mg/cm^2$이하로 산에 대한 변화량은 거의 없었다. 주입재인 모르타르의 산성에 대한 저항성은 일반 콘크리트에 비해 우수하였으며 기존 모르타르에 비해 비확선성 또한 우수하였다. 장거리압송시험은 200m까지 안정적인 압송이 가능하여 이 기술에 필요한 요구 성능을 확보한 것으로 나타났다.

  • PDF

쌍안정성을 가지는 단분자 기억소자 디자인

  • Park, Tae-Yong
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.37-52
    • /
    • 2013
  • 무어의 법칙에 따르면, 반도체의 집적도 2년마다 2배씩 증가한다고 한다. 무어의 법칙은 지금까지는 집적회로 기술의 발전을 잘 예측했다. 하지만 트랜지스터의 사이즈를 줄일수록 누수전류와 회로의 저항을 조절하기 어렵기 때문에 트랜지스터의 소형화에는 한계가 있다. 우리는 곧 무어의 법칙의 한계를 맞이할 것이다. 그래서 트랜지스터를 더욱 소형화시키기 위해서는 bottom-up analysis가 필요한 시점이다. Top-down analysis가 초기의 커다란 트랜지스터에서 점점 소형화를 시켜 작은 트랜지스터를 만든다는 개념인 반면, Bottom-up analysis는 처음부터 작은 분자를 조작하여 트랜지스터와 같은 성질을 띄도록 만드는 개념이다. 분자가 기억소자로서 이용되려면 저항이 다른 2가지 안정한 상태가 필요하다. 이번 연구에서 나는 기억소자를 디자인 하기 위하여 high spin state와 low spin state 두 가지 안정한 상태를 가지는 spin crossover complex를 이용하기로 했다. 이전의 연구에서 spin crossover 는 전기장을 이용해서도 유도될 수 있다고 확신하였고, 이를 이용해서 기억소자를 디자인하기로 하였다. 이번 연구를 위해서 symmetry를 가지는 octahedral spin crossover complex를 디자인하였고 이를 '기억 분자'라고 명명했다. 그리고 이 분자의 high spin state와 low spin state가 전기장을 이용하여 서로 바뀔 수 있는지 가능성을 DFT with B3LYP functional을 이용해서 비교했다. 그 결과로 전기장을 이용하여 기억분자의 spin crossover을 일으킬 수는 있지만 abnormally strong electric field를 써야 한다는 사실을 알아냈다. 이번 연구를 토대로 추후의 연구를 위해, 기억소자가 되기 위하여 분자가 어떤 특징을 만족시켜야 하는지를 분석했다.

  • PDF

Engineering Properties of Sewage Polymer Concrete Culvert (폴리머 콘크리트를 적용한 하수암거의 공학적 특성)

  • Kwon, Seung Jun;Min, Byung Yoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2012
  • Concrete sewage culvert shows degradation with time since it is always exposed to various harmful ions, and deterioration of concrete culvert propagates to structural safety problems. After reclamation, maintenance for concrete sewage culvert is very difficult so that high durable and structural performance are essential for the sewage concrete culvert. Recently polymer concrete has been used to improve mechanical properties and durability performance. In this paper, engineering properties are evaluated for sewage culvert made with polymer concrete, and leakage and adhesive strength between joints are evaluated with small-scale models. The polymer sewage culvert shows high compressive strength over 100MPa with low water permeability and chloride penetration. Furthermore, high resistances to chemical and biological attack are evaluated. Through tests for leakage and adhesive, unification of joints is verified with evaluation of no leakage and high adhesive strength. Precast polymer sewage culvert in this paper can be actively used for severe conditions like sewage lines.

Evaluation of the Pull-out Resistance of the SMA Wire Connector (SMA 와이어를 이용한 연결재의 인발저항성능 평가)

  • Jung, Chi-Young;Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • Precast concrete (PC) structure is one of the type of the structures which is made in a facility prior to installing it to a construction field. The contact surfaces between two PC structures should be treated for obtaining enough binding force by inducing prestressing force. However, in the many cases, the contact surface causes the crack and leakage of water. These cracks and water leakage can cause the corrosion of the rebar, and the corrosion of the rebar can severely reduce the long-term durability. In this study, the SMA wire connector is suggested to solve the problem with the contact surfaces between two PC structures. The pull-out resistance of the suggested SMA wire connector is evaluated by conducting the tests to find the effect of the number of wires, shape of connector part, and shape memory effect. As a result of this study, the empirical formula is suggested to estimate the pull-out resistance related with the effects of the shape of the connector, shape memory effect, and the adhesive force. The validity between the estimated pull-out resistance and the measured value is confirmed.

Effects of Heavy Metal and Salinity on Electrical Conductivity in Fully Saturated Sand (포화된 사질토의 전기전도도에 중금속과 염분 농도가 미치는 영향)

  • Lee, Dongsoo;Hong, Young-Ho;Hong, Won-Teak;Chae, Kwang-Seok;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.10
    • /
    • pp.23-34
    • /
    • 2017
  • As the electrical property of fully saturated soils is dependent on the pore water, it has been commonly used for the detection of the contamination into the ground. The objective of this study is to investigate the electrical characteristics according to the salinity and the lead concentration in fully saturated soils. Fresh water and saline water with the salinity of 1%, 2% and 3%, which are mixed with 6 different lead solutions with the range of 0~10 mg/L, are prepared in the cylindrical cell incorporated with sensors for measuring electrical resistance and time domain reflectometry signal. Then, the dried sands are water-pluviated into the cell. The electrical resistance and the time domain reflectometry signal are used to estimate the electrical conductivity. Test results show that electrical conductivity determined from electrical resistance at the frequency of 1 kHz continuously increases with an increase in the lead concentration, thus it may be used for the estimation of the contaminant level. In addition, the electrical conductivity estimated by the time domain reflectometry changes even at very low concentration of lead, the variation rate decreases as the lead concentration increases. Thus, the time domain reflectometry can be used for the investigation of the heavy metal leakage. This study demonstrates that complementary characteristics of electrical resistance and time domain reflectometry may be used for the detection of the leakage and contamination of heavy metal in coastal and marine environments.

Assessment of Ground Improvement Achieved using the Cement Grouting by Vibration Method (CGVM 공법을 이용한 지반개량 효과 검증)

  • Kim, Jong-Tae;Choi, Young-Jun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.497-503
    • /
    • 2016
  • The cement grouting by vibration method (CGVM), a new construction technology developed in Korea, aims to efficiently reinforce a target ground area by injecting vibrated grout into it. The present study applies the CGVM to test sites and verifies its effect. Standard penetration tests (SPTs), field permeability tests, and geophysical surveys were conducted in two study areas, and the results were compared between before and after CGVM application. The SPT conducted before and after the CGVM application showed that the N value was increased by 33.57% point to 60.90% point. The field permeability test showed that the permeability coefficient decreased. These results indicate that CGVM may increase imperviousness and improve reservoir system stability. In addition, a resistivity survey found no low-resistivity zone, unlike before the CGVM application, thereby indicating the excellent grouting effect of the CGVM.

Dissolution Resistance Property of Modified Asphalt Waterproofing Sheet Coated with Polyamide Film by SEM-EDX Analysis (폴리아마이드 필름이 코팅된 개량 아스팔트 방수시트의 SEM-EDX 분석을 통한 유기용제 저항성 확인)

  • An, Ki-Won;Yoo, Jae-Yong;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.437-444
    • /
    • 2017
  • In the composite waterproofing method in which a polyurethane coating waterproofing material is applied on the modified asphalt waterproofing sheet, the organic solvent is diluted in the coating waterproofing material in order to improve the workability. However, since the organic solvent is not volatilized before the curing of the polyurethane coating waterproofing material, the organic solvent causes dissolution of asphalt layer, thereby causing oil leakage. As a result, a polyamide film having a high dissolution resistance property was laminated on modified asphalt sheet, and through testing the dissolution resistance was visually confirmed and quantitative analysis of the polyamide film by SEM-EDX analysis was also used to confirmed the dissolution resistance of the polyamide film.