• Title/Summary/Keyword: 누설모델

Search Result 120, Processing Time 0.028 seconds

Numerical and experimental investigations on the aerodynamic and aeroacoustic performance of the blade winglet tip shape of the axial-flow fan (축류팬 날개 끝 윙렛 형상의 적용 유무에 따른 공기역학적 성능 및 유동 소음에 관한 수치적/실험적 연구)

  • Seo-Yoon Ryu;Cheolung Cheong;Jong Wook Kim;Byeong Il Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.103-111
    • /
    • 2024
  • Axial-flow fans are used to transport fluids in relatively low-pressure flow regimes, and a variety of design variables are employed. The tip geometry of an axial fan plays a dominant role in its flow and noise performance, and two of the most prominent flow phenomena are the tip vortex and the tip leakage vortex that occur at the tip of the blade. Various studies have been conducted to control these three-dimensional flow structures, and winglet geometries have been developed in the aircraft field to suppress wingtip vortices and increase efficiency. In this study, a numerical and experimental study was conducted to analyze the effect of winglet geometry applied to an axial fan blade for an air conditioner outdoor unit. The unsteady Reynolds-Averaged Navier-Stokes (RANS) equation and the FfocwsWilliams and Hawkings (FW-H) equation were numerically solved based on computational fluid dynamics techniques to analyze the three-dimensional flow structure and flow noise numerically, and the validity of the numerical method was verified by comparison with experimental results. The differences in the formation of tip vortex and tip leakage vortex depending on the winglet geometry were compared through a three-dimensional flow field, and the resulting aerodynamic performance was quantitatively compared. In addition, the effect of winglet geometry on flow noise was evaluated by numerically simulating noise based on the predicted flow field. A prototype of the target fan model was built, and flow and noise experiments were conducted to evaluate the actual performance quantitatively.

Investigation of Error Factors from an Impact Hammer Test for Developing a Statistic Based Technique for Model Updating (통계 기반 모델 개선을 위한 임팩트 해머 실험의 오차 요인 분석)

  • Lee, Su;Lee, Jin Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.185-198
    • /
    • 2016
  • In this work, experimental errors from an impact hammer test were investigated to develop a statistic-based technique for updating a finite element model. Digital signal processing was analyzed by using theoretical models and experiments when errors occurred during the experimental procedure. First, the duration time and peak level of the excitation signal, the stiffness and position of elastic springs connecting the specimen as well as the support, position and mass of the accelerometer were considered as error factors during the experiment. Then the picket fence effect, leakage, and exponential window function were considered as candidate error factors during the digital signal processing. Finally, methods to reduce errors are suggested.

Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter (ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계)

  • 이득기;윤길문;차영길;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.231-239
    • /
    • 1998
  • This paper presents the dynamic analysis and control loop design of a zero voltage switching full bridge (ZVS-FB) PWM DC/DC converter. The small-signal model is derived incorporating the effects of phase shift control and the utilization of transformer leakage inductance and power FET junction capacitance to achieve zero voltage resonant switching. These effects are modeled by introducing additional feedforward and feedback terms for duty cycle modulation. Based on the results of the small-signal analysis, the control loop is designed using a simple two-pole one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system is carried out and the potential of the zero voltage switching and the superiority of the dynamic characteristics are verified through the experiment with a 2 kW prototype converter.

  • PDF

Design of 5'' True Color FED Driving System (5'' True Color FED 구동시스템 설계)

  • Shin, Hong-Jae;Kwon, Oh-Kyong;Kwack, Kae-Dal
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.70-78
    • /
    • 2001
  • We have developed a novel driving system of 5' true color FED using voltage controlled PWM method which has current control effect. The proposed method has the advantage of voltage controlled pulse width modulation method and current control method. Also, we propose a new circuit model of FED subpixel for circuit simulation of FED driving circuits, considering some parasitic effects, i.e., cross talk, line coupling effect and leakage current to the adjacent cathode lines. Output stage of the data driving circuit is optimized using the proposed circuit model. In video data processing, FED controller uses the parallel processing of R.G.B input data, so duty ratio is maximized and brightness of FED increases. With this results, no noise and high quality performance is achieved in display of 5' true color FED.

  • PDF

Structural Integrity of a Fuel Assembly for the Secondary Side Pipe Breaks (2차측 배관파단에 대한 핵연료 집합체의 구조 건전성)

  • Jhung, M. J.
    • Journal of KSNVE
    • /
    • v.6 no.6
    • /
    • pp.827-834
    • /
    • 1996
  • The effect of pipe breaks in the secondary side is investigated as a part of the fuel assembly qualification program. Using the detailed dynamic analysis of a reactor core, peak responses for the motions induced from pipe breaks are obtained for a detailed core model. The secondary side pipe breaks such as main steam line and economizer feedwater line braksare considered because leak-before-break methodology has provided a technical basis for the elimination of double ended guillotine breaks of all high energy piping systems with a diameter of 10 inches or over in the primary side from the design basis. The dynamic responses such as fuel assembly shear force, bending moment, axial force and displacement, and spacer grid impact loads are carefully investigated. Also, the stress analysis is performed and the effect of the secondary side pipe breaks on the fuel assembly structural integrity under the faulted condition is addressed.

  • PDF

An Improved Method for Mesh Grounding System Using Spaced Arrangement of Grounding Conductor (접지도체의 간격배치에 따른 개선된 접지설비 모델)

  • Song, Young-Joo;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.57-65
    • /
    • 2005
  • No matter how well the equally spaced grounding grid is designed, there we questions keep rising, such as leakage of current from comer conductor, high voltage of touch voltage in comers of grid than in center, and high material cost for grounding grid. The best-fitted design for unequally spaced grounding grid is a part that must be considered. Explain advantages of unequally spaced grounding grid and lead formula by dividing the number of grid division, j, into 20, instead of 7. Then, present Dij, which is optimum rate for unequally spaced grounding grid and verify safety and economy of the unequally spaced grounding grid by computer simulation with a poly-nominal function form.

축류회전차 익말단 틈새유동에 대한 수치해석

  • No, Su-Hyeok;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.336-345
    • /
    • 1998
  • The substantial loss behind axial flow rotor was generated by wake, various vortices in the hub region and the leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip was one of the main causes of the reduction of performance, the generation of noise and the aerodynamic vibration in rotor downstream. In this study, the three-dimensional flowfields in an axial flow rotor for various tip clearances were calculated, and the numerical results were compared with the experimental ones. The numerical technique was based on SIMPLE algorithm using standard k-.epsilon. model (WFM). Through calculations, the effects of the tip clearance on the overall performance of rotor and the loss distributions, and the increase in the displacement, momentum, and blade-force-deficit thickness of the casing wall boundary layer were investigated. The mass-averaged flow variables behind rotor agreed well with the experimental results. The presence of the tip leakage vortex behind rotor was described well. Although the loci of leakage vortex by calculation showed some differences compared with the experimental results, its behavior for various tip clearances was clarified by examining the loci of vortex center.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

Detection Algorithm and Characteristics on DC Residual Current based on Analysis of IEC60479 Impedance Model for Human Body (IEC60479 인체 임피던스 모델에 근거한 직류누설전류의 특성 및 검출 알고리즘)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.305-312
    • /
    • 2018
  • DC distribution systems has recently taken the spotlight. Concerns over human safety and stability facility are raised in DC distribution systems. Std. IEC 60479 provides basic guidance on "the effects of shock current on human beings and livestock" for use in the establishment of electrical safety requirements and suggests an electrical impedance of the human body. This study analyzes impedance spectrums based on the electrical equivalent impedance circuit for the human body; human body impedances measured by experiments are analyzed below the fundamental frequency (60 Hz). The analysis shows that the equivalent impedance circuit for the human body should be modified at least in low-frequency range below the fundamental frequency (60 Hz). The DC residual current detection method that can classify electric shock accidents of humans and electric leakages of facilities is proposed by applying the analysis result. The detection method is verified by experiments on livestock.

A Research on Power Decoupled Quadruple-Active-Bridge Converter Adopting Multiple Transformers for DC Distribution System (다수의 변압기를 도입하여 포트 간 전력의 비동조화를 달성할 수 있는 DC 배전용 Quadruple-Active-Bridge 컨버터에 관한 연구)

  • Kim, Inhyeok;Lee, Jun-Young;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.139-141
    • /
    • 2020
  • 본 논문에선 다수의 변압기를 도입하여 복수의 입출력 포트 간 전력 동조화 문제를 해결할 수 있는 Quadruple-Active-Bridge(QAB) 컨버터를 제안한다. 기존 QAB 컨버터는 단일 변압기를 사용하기 때문에 입출력 포트 사이의 전력 동조화 문제가 발생한다. 따라서 단일 변압기에서 포트 간 전력 비동조화를 달성하기 위해 입력 포트의 누설 인덕턴스를 최소화하는 최적의 변압기 설계가 필요하나, 복수의 권선 구조로 인해 최적의 설계가 어렵다는 단점이 있다. 이러한 문제점을 해결하고자 본 논문에선 기존의 단일 변압기와 복수의 변압기를 함께 설치하는 구조를 제안한다. 제안한 구조를 통해 별도의 비동조화 알고리즘 없이 출력 포트 사이의 전력 동조화 문제를 해결할 수 있다. 그리고 변압기의 설계도 복잡했던 기존 QAB 와는 달리 쉬워지는 이점도 있다. 제안한 컨버터의 구조 및 전력 비동조화를 등가 모델을 통해 이론적으로 분석한다. 그리고 이를 검증하고자 3 kW급 시작품을 통해 전력전달 구조 및 전력 비동조화를 검증한다.

  • PDF