• Title/Summary/Keyword: 누설모델

Search Result 120, Processing Time 0.029 seconds

One Dimensional Leakage Inductance Calculation of Superconducting Transformer (1 차원모델을 이용한 초전도 변압기의 누설인덕턴스 계산)

  • Kim, Tae-Ki;Nah, Wan-Soo;Cha, Guee-Soo;Hahn, Song-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.256-259
    • /
    • 1997
  • This paper describes on the leakage inductance calculations of superconducting (s/c) tranformer. When s/c transformer quenches, the magnetic energy stored in the leakage inductance dissipates in the form of Joule heating. So, it is highly desired to estimate the leakage inductances of a s/c transformer as it is designed. In this paper, we calculated the leakage inductance of sic transformer, using zeroth and first order model, and the calculated results were compared with the measured ones. It shows that 1st order model is enough to estimate the leakage inductacne of s/c transformer.

  • PDF

3-D FEA and Shape Optimization of BLDC Motor (BLDC 모터의 3차원 유한요소해석 및 형상 최적설계)

  • Wang, Se-Myung;Kang, Je-Nam;Yoon, Hee-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.43-45
    • /
    • 1999
  • 지금까지 사용된 2차원 유한요소해석은 자계의 프린징(Fringing) 및 누설 자계 등을 무시하기 때문에 정확한 특성을 파악하기 위해서는 3차원 모델을 사용하여야 한다. BLDC 모터의 회전자(자석)의 높이를 고정시킨 상태에서 고정자(Core) 높이의 변화에 따른 코깅(Cogging) 토크의 해석을 통해 높이 비에 대한 2차원과 3차원 유한요소해석 결과 사이에의 상관 오차에 대한 연구를 수행하였다 또한. 정자기의 3차원 형상 설계 민감도 해석 기법을 개발하였다. 개발된 정자기 민감도 프로그램(MAGSEN-magnetic sensitivity)은 유용성과 실용성을 보이기 위하여 BLDC 모터의 코깅토크를 줄이는 형상 최적설계에 적용되었다.

  • PDF

Rotordynamic Analysis of See-through-type Labyrinth Seal Using 3D CFD (3D CFD를 활용한 관통 래버린스 실의 회전체 동역학적 해석)

  • Ha, Tae Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.44-50
    • /
    • 2015
  • Labyrinth seals are commonly used in various kinds of turbomachinery to reduce leakage flow. In the present 3D CFD analysis of see-through-type labyrinth air seal, the methodology of determining leakage and rotordynamic coefficients is suggested with the relative coordinate system for steady-state simulation. The leakage flow and rotordynamic forces predicted by using different solvers and turbulent models of FLUENT are compared with the results of the existing bulk-flow analysis code LABYSEAL.FOR and experiment. The present CFD result of direct stiffness(K) shows only improvement in prediction. The results of leakage and rotordynamic coefficients as well as computing time are sensitive against the used solver and turbulent model.

Developing Analysis Model for Evaluation of HCVT Materialization Possibility, and Examining It's Characteristics (HCVT 구현 가능성 평가를 위한 해석모델 개발 및 특성검토)

  • Noh, Daekyung;Jung, Dongsoo;Jang, Joosup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.39-46
    • /
    • 2016
  • This paper reviews design validity before manufacturing HCVT prototype through simulation. The component part is being devided, modeled and checked if it works well to an designer's original intent about some active modes. Also, the dynamic characteristic is examined how it changes according to alteration of pressure, friction and leak rate. Finally, HCVT design plan is being confirmed if it could be materialized through those analysis.

A Simple Parameter Extraction Method for Magnetic Transformers using PSIM (PSIM 모델을 이용한 변압기 회로상수 추출 방법)

  • Choi, Hee-Su;Park, Jun-Young;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.44-45
    • /
    • 2015
  • 고밀도 고효율의 전원회로에서는 변압기의 정확한 모델링이 중요하다. 기존의 FEM(Finite Element Method)등 전자기장 해석 방식은 계산시간이 길고 모델링이 불편하다는 단점을 가지고 있다. 본 논문에서는 PSIM이 제공하는 Magnetic Element 블록을 이용한 시뮬레이션으로 변압기의 회로상수를 빠르게 추출하는 방법을 제시한다. 성능을 검증하기 위해 LLC 변압기에 제안방법을 적용하여 회로상수를 추출하고, 이를 실험결과와 비교 분석한 결과 약 누설 인덕턴스는 약 9% 자화 인덕턴스는 약 16% 오차가 나왔다.

  • PDF

Development of ISOP active-clamp forward converter for 3.2kW DC-DC Converter of EV application (전기자동차용 3.2kW급 DC-DC 컨버터를 위한 ISOP 능동클램프 포워드 컨버터 개발)

  • Kim, Kangsan;Kim, Byeongwoo;Cho, Woosik;Naradhipa, Adhistira;Choi, Sewan;Huh, Dongyoung;Kim, Soohong;Cho, Kyungrae
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.223-224
    • /
    • 2018
  • 본 논문에서는 전기자동차용 저전압 배터리 충전기(Low-voltage DC-DC Converter, LDC)에 적합한 입력 직렬-출력 병렬 구조의 능동 클램프 포워드 컨버터의 모델링 및 제어기 설계를 제안한다. 제안하는 컨버터는 모든 스위치에서 소프트 스위칭을 성취하기 때문에 높은 효율을 달성할 수 있다. 또한 누설 인덕턴스의 영향을 포함한 컨버터의 정확한 소신호 모델을 통하여 모델링 기반의 제어기 설계를 제시한다. 제어기의 시뮬레이션 및 3.2kW급 시작품의 실험을 통하여 제안하는 컨버터의 성능을 검증하였다.

  • PDF

Study of the New Structure of Inter-Poly Dielectric Film of Flash EEPROM (Flash EEPROM의 Inter-Poly Dielectric 막의 새로운 구조에 관한 연구)

  • Shin, Bong-Jo;Park, Keun-Hyung
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.10
    • /
    • pp.9-16
    • /
    • 1999
  • When the conventional IPD (inter-poly-dielctrics) layer with ONO(oxide-nitride-oxide) structure was used in the Flash EEPROM cell, its data retention characteristics were significanfly degraded because the top oxide of the ONO layer was etched off due to the cleaning process used in the gate oxidation process for the peripheral MOSFETs. When the IPD layer with the ONON(oxide-nitride-oxide-nitride) was used there, however, its data retention characteristics were much improved because the top nitride of the ONON layer protected the top oxide from being etched in the cleaning process. For the modelling of the data retention characteristics of the Flash EEPROM cell with the ONON IPD layer, the decrease of the threshold voltage cue to the charge loss during the bake was here given by the empirical relation ${\Delta}V_t\; = \;{\beta}t^me^{-ea/kT}$ and the values of the ${\beta}$=184.7, m=0.224, Ea=0.31 eV were obtained with the experimental measurements. The activation energy of 0.31eV implies that the decrease of the threshold voltage by the back was dur to the movement of the trapped electrons inside the inter-oxide nitride layer. On the other hand, the results of the computer simulation using the model were found to be well consistent with the results of the electrical measurements when the thermal budget of the bake was not high. However, the latter was larger then the former in the case of the high thermal budger, This seems to be due to the leakage current generated by the extraction of the electrons with the bake which were injected into the inter-oxide niride later and were trapped there during the programming, and played the role to prevent the leakage current. To prevent the generation of the leakage current, it is required that the inter-oxide nitride layer and the top oxide layer be made as thin and as thick as possible, respectively.

  • PDF

Analysis of Thermal Interrelation by Leakage Current in Open and Closed Statues (개방 및 밀폐상태에서의 누설 전류에 대한 열적 상관관계 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Choi, Seung-Ho;Lee, Jong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.7-12
    • /
    • 2010
  • This paper is aimed the measurement and estimation the thermal interrelation based on leakage current. The leakage models are analyzed by parameters in open and closed (Panel) states and with wood dust and rainwater, charcoal powder in leakage current occurred point. The thermal characteristic of open state that leakage current is inputted in 90 mA is higher in charcoal powder ($105^{\circ}C$) than in wood dust and rainwater ($88.8^{\circ}C$). Charcoal powder that is inputted in 110 mA shows high thermal characteristic ($238.6^{\circ}C$) and the thermal ($238.6^{\circ}C$) is caused by material strain of electrical wire insulation and Panel. The closed state in 90 mA is higher in charcoal powder ($250.6^{\circ}C$) than in wood dust and rainwater ($90.8^{\circ}C$). The open and closed state appear thermal characteristics of two times in charcoal powder than in wood dust and rainwater. The thermal data that are open and close states are used electrical fire investigation and thermal characteristic for Leakage current.

Design Enhancement of CANDU S/F Storage Basket (CANDU 사용후핵연료 저장바스켓 설계 개선안 도출)

  • Choi, Woo-Seok;Seo, Ki-Seog;Park, Wan-Gyu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2012
  • Necessity of demonstration test to evaluate the structural integrity of a basket for accident conditions arose during license approval procedure for the WSPP's dry storage facility named MACSTOR/KN-400. A drop test facility for demonstration was constructed in KAERI site and demonstration tests for basket drop were conducted. As the upper welding region of a loaded basket was collided with a dropped basket during the drop test, the welding in this region was fractured and leakage happened after the drop test. The enhancement of basket design was needed since the existing basket design was not able to satisfy the performance requirement. The directions for design modification were determined and six enhanced designs were derived based on these directions. Structural analyses and specimen tests for each enhanced design were conducted. By evaluating structural analysis results and test results, one among six enhanced designs was decided as a final design for revision. The final design was the one to reduce the height of central post of a basket and to decrease the impact velocity with a dropped basket. Test basket models were fabricated with accordance with the final enhanced design. Additional demonstration test was performed for this test model and all the performance requirements were satisfied.

Assessment of the Internal Pressure Fragility of the PWR Containment Building Using a Nonlinear Finite Element Analysis (비선형 유한요소 해석을 이용한 PWR 격납건물의 내압 취약도 평가)

  • Hahm, Daegi;Park, Hyung-Kui;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2014
  • In this study, the probabilistic internal pressure fragility analysis was performed by using the non-linear finite element analysis method. The target structure is one of the containment buildings of typical domestic pressurized water reactors(PWRs). The 3-dimensional finite element model of the containment building was developed with considering the large equipment hatches. To consider uncertainties in the material properties and structural capacities, we performed the sensitivity analysis of the ultimate pressure capacity with respect to the variation of four important uncertain parameters. The results of the sensitivity analysis were used to the selection of the probabilistic variables and the determination of their probabilistic parameters. To reflect the present condition of the tendon pre-stressing force, the data of the pre-stressing force acquired from the in-service inspections of tendon forces were used for the determination of the median value. Two failure modes(leak, rupture) were considered and their limit states were defined to assess the internal pressure fragility of target containment building. The internal pressure fragilities for each failure mode were evaluated in terms of median internal pressure capacity, high confidence low probability of failure(HCLPF) capacity, and fragility curves with respect to the confidence levels. The HCLPF capacity was 115.9 psig for leak failure mode, and 125.0 psig for rupture failure mode.