• Title/Summary/Keyword: 뇌방전

Search Result 49, Processing Time 0.023 seconds

뇌방전 현상과 전력용 피뢰기의 최근 동향

  • 조규심
    • 전기의세계
    • /
    • v.45 no.9
    • /
    • pp.24-30
    • /
    • 1996
  • 뇌방전현상에는, 아직 불명한 부분도 있으나 많은 사람들의 연구에 의해 뇌운의 발생기구, 구조, 뇌격전류의 특성등이 상당히 명백해졌다. 이하 이것들을 설명한다.

  • PDF

The Characteristics of Winter Lightning Observed in the Mid-western Part of Japan (일본 중서부지방에서 발생하는 동계 뇌 방전의 특징)

  • Lee, Jong-Ho;Kawasaki, Z.;Ryu, Chan-Su
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.181-189
    • /
    • 2003
  • This study analyzes the results of thunderstorm data observed in the mid-western part of Japan during the winter of 1996-1997. There were 35 instances of thunderstorms with 4,426 instances of lightning detected during the observation period. This study estimates the frequency of lightning occurrence through classification of detected lightning into two types, and analyzes the relationship between lightning types and synoptic pattern. According to the analyzed results, cloud-to-cloud discharge and positive polarity occupied 78% and 42.3% of total discharge, respectively. It is rare for lightning to occur in the winter season, usually occuring during the night (midnight to 5 a.m.). Lightning frequently occurs when there is a prevailing synoptic wind from the norhwest. According to the analyzed results of multiplicity and multi-point lightning, the mean values of multiplicity and multi-point lightning are 1.4 and 1.2, respectively.

뇌해의 방호대책 (상)

  • 김준현
    • 전기의세계
    • /
    • v.30 no.10
    • /
    • pp.611-617
    • /
    • 1981
  • 본고의 내용은 다음과 같다. 1. 뇌현상 1.1 뇌운 1.2 뇌방전 2. 방호대책 2.1 대증적 방법

  • PDF

A Study on the lightning Discharge Positioning (뇌방전 위치표정에 관한 연구(I))

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Ahn, Chang-Hwan;Lee, Young-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.40-45
    • /
    • 2007
  • Lightning warning system plays an important role in protecting human life and other facilities from lightning return strokes. This paper dealt with lightning positioning algorithms and circuits as a main function of lightning warning system, which monitor movements and activities of thunderclouds. Electric field component produced by lightning discharge is detected by the configuration of a whip antenna and a narrow-band resonance amplifier with center frequency of 300[kHz]. Measurement circuit of magnetic field waveform consists of a crossed-loop coil and an integral amplifier, and its frequency bandwidth is ranges from 5[kHz] to 1.2[MHz]. The polarity of lightning discharge is discriminated by electric field component. After-fixing the polarity, we can calculate the direction and distance of lightning discharge by the peak and the zero-cross time of magnetic field waveform.

Characteristics of the Electric and Magnetic Field Waveforms Radiated by Lightning Discharges (뇌방전에 의해 방사되는 전계와 자계파형의 특성)

  • 이복희;이경옥
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.4
    • /
    • pp.300-309
    • /
    • 1996
  • The electric and magnetic fields radiated by lightning discharges are significantly changeable in amplitude and time, one of the topics concerning electromagnetic compatibility of modern electronic systems is the efficient and economic protection against transient voltages caused by not only by direct but also by nearly lightning strokes. In this paper, in order to obtain the detailed informations about lightning electromagnetic impulse waveforms, the electric and magnetic fields radiated by lightning discharges in the summer of 1995 were measured by a fast electric antenna and a loop-type magnetic field sensor, and their charac- teristics were presented and analyzed. The signals of the electric and magnetic fields were re- corded continuously by a transient digitizer having a resolution of 12 bit and a memory capacity of 5000 point and using a sampling time of 200 ns. The electric and magnetic field waveforms associated with lightning return strokes are significantly different with those of intracloud discharges. The magnetic fields radiated by intracloud lightning discharges have essentially the same waveforms as the electric field when the lightning discharhes are at distance of 50 km or more. Also the main frequency components of the electric and magnetic fields radiated by lightning discharges range from a few kHz to several hundred kHz.

  • PDF

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

A Solution to Protect the Power Supply Circuit Employing a New Spark-gap during Lightning Surge Inflow (뇌서지 유입 시 새로운 스파크-갭을 활용한 전원회로 보호 대책)

  • Lee, Kang-Hee;Park, Jun-Woo;Ryu, Dong-Kyun;Won, Jae-Sun;Hong, Sung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.153-154
    • /
    • 2013
  • 고전압, 대전류를 갖는 뇌서지는 전원회로에 유입되었을 때 소자 파손 및 회로 오동작 등의 문제를 일으킨다. 이에 대한 보호대책으로 SPD(Surge Protection Device)소자와 스파크-갭(Spark-gap)을 주로 사용한다. 이 때, 기존의 스파크-갭은 뇌서지 유입 시 방전현상 이후에 발생된 스파크-갭의 패턴 마모로 패턴의 복구가 불가능하고, 불규칙하고 변칙적인 방전으로 인하여 발생되는 서지주요 예측경로의 소자 및 패턴 파괴와 같이 2차적인 문제를 발생시킨다. 이를 해결하기 위해 본 논문에서는 초기 유입 시부터 스파크-갭의 방전을 통해 에너지를 우회시킴으로서 전원회로의 뇌서지 부담을 줄여 전원회로의 안전성 및 안정적인 정상동작을 확보하는 대책을 제안하고, 스파크-갭의 구조에 따른 효과를 실험을 통해 검증한다.

  • PDF

An Automatic Measuring System of the Electric Fields Produced by Lightning Strokes (뇌방전에 의하여 발생하는 전장의 자동측정시스템)

  • Lee, Bok-Hee;Ahn, Chang-Hwan;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 1996
  • This paper deals with the electric field sensor and automatic measuring system of the time-varying space electric field produced by lightning discharges. The theoretical principle and the design rule of the measuring devices are investigated, and the semisphere-type electric field sensor and the signal process system are fabricated. From the calibration experiments, the frequency bandwidth of the measuring system ranges from 200 [Hz] to 1.56 [MHz] and the sensitivity is 0.96 [m V/V/m] as the amplification gain is 10. In addition, the electric field waveforms produced by lightning discharges are observed by the proposed electric field measuring system from June to August in 1995. The data is sampled with the time interval of 200 [ns] and is automatically recorded by transient signal analyzer(Necolet Pro 30), the resolution of which is 12 bit. And it is registered at personal computer. The electric field waveforms produced by intracloud discharge tend to be bipolar, with two or three narrow and fast rising pulses superimposed on the initial half-cycle.

  • PDF