• Title/Summary/Keyword: 높은 입사 음압

Search Result 4, Processing Time 0.017 seconds

Absorption Characteristics of Micro-perforated Panel Absorber According to High Incident Pressure Magnitude and Variation of Geometric Parameters (높은 입사 음압 및 설계 인자의 변화에 따른 미세 천공판 흡음 기구의 흡음 특성)

  • Park, Soon-Hong;Seo, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.11
    • /
    • pp.1059-1066
    • /
    • 2011
  • The micro-perforated panel absorber(MPPA) is one of promising noise control elements because of its applicability to extreme environments where general porous materials cannot be used. Since the MPPA is inherently non-porous sound absorber, it can be a good candidate of acoustic protection system of a space launcher. The overall sound pressure level inside payload fairings of commercial launch vehicles is so high(around 140 dB OASPL) that the conventional linear impedance model cannot be directly applied to the design of the acoustic protection systems. In this paper an acoustic impedance models of a micro-perforated panel absorber at high sound pressure environment were reviewed and the use of the impedance on the practical design of MPPAs was addressed. The variation of absorption characteristics of MPPA was discussed according to the design parameters, e.g., perforation ratio, the minute hole diameter, the thickness of MPP and the incident sound pressure level.

Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure (높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계)

  • Park, Soon-Hong;Seo, Sang-Hyun;Jang, Young-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.

Analysis of Acoustic Back Scattering from Bubble Columns in Water (수중 기포기둥에 의한 음파의 후방 산란특성 분석)

  • Park, K.-J.;Yoon, S.-W.;Roy, R.A.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.36-43
    • /
    • 1991
  • Acoustic backscattering from a buble column in water was studied theoretically and experimentally. For theoretical analysis a general scattering theory was used by assuming the bubble column to be lumped element scatterer which can be characterized by its shape, void fraction and dimensions. When the void fraction is less than 1% and the incident frequency is higher than individual bubble resonance frequencies, the experimental results show that the acoustic backscattering from a bubble column depends mainly on the void fraction rather than the individual bubble sizes. It was also theoretically and experimentally observed that the acoustic backscattering levels were increased and their peaks moved to the lower frequency regin by raising the void fraction of bubble column.

  • PDF

Absorption Characteristics of Micro-perforated Panel Absorber According to Incident Pressure Magnitude and Its Geometric Parameters (가진 음압 및 설계 인자에 따른 미세 천공판 흡음 기구의 흡음 특성)

  • Park, Soon-Hong;Seo, Sang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.178-185
    • /
    • 2011
  • The micro-perforated panel absorber (MPPA) is one of promising noise control elements because of its applicability to extreme environments where general porous materials cannot be used. Since the MPPA is inherently non-porous sound absorber, it can be a good candidate of acoustic protection system of a space launcher. The overall sound pressure level inside payload fairings of commercial launch vehicles is so high (around 140 dB OASPL) that the conventional linear impedance model cannot be directly applied to the design of the acoustic protection systems. In this paper an acoustic impedance models of a micro-perforated panel absorber at high sound pressure environment were reviewed and the use of the impedance on the practical design of MPPAs was addressed. The variation of absorption characteristics of MPPA was discussed according to the design parameters, e.g., perforation ratio, the minute hole diameter, the thickness of MPP and the incident sound pressure level.

  • PDF