• 제목/요약/키워드: 높은 구름/미끄럼 비

검색결과 1건 처리시간 0.014초

높은 구름/미끄럼 비를 갖는 점 접촉 EHL 하에서의 온도분포와 유막 두께 분포의 측정 (Measurements of film thickness and temperature distribution in EHL point contact at high roll/slip ratios)

  • 김성기;팔목화행;중원강광;경극계사;김경웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.293-298
    • /
    • 2001
  • In this paper, film thickness and temperature distribution are measured in EHL point contact at high roll/slip ratios. Infrared temperature mapping with two band pass filters, proposed by Ausherman (1976), is used to measure temperature distribution. And the optical interferometric method with two filters (red and green filters) is used to measure film thickness. Result of experiment showed that temperature rising at film and ball surface occurred very dramatically in Dimple zone. As slip velocity, roll/slip ratio and load increased, size of Dimple and temperature rising became more large. In addition, position and shape of Dimple were changed by roll/slip ratios, and increasing of Dimple size decreased traction coefficient. In short, it is appointed that the Dimple phenomenon be developed by the effect of viscosity wedge.

  • PDF