• Title/Summary/Keyword: 농도 측정

Search Result 10,125, Processing Time 0.044 seconds

Improvement of Pesticide Sorption Measurement Method for Soils with Low Sorption (흡착력(吸着力)이 낮은 토양(土壤)에서의 농약흡착(農藥吸着) 측정법(測定法) 개발(開發))

  • Kim, Sun-Kwan;Green, Richard E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.2
    • /
    • pp.124-129
    • /
    • 1991
  • A mass balance method which measures directly both the sorbed pesticide and equilibrium solution concentration was compared with the batch method in a hypothetical experiment to determine the precision of sorption measurement. The mass balance method was shown to improve precision of sorption measurement. The two methods were also tested experimentally on the Wahiawa soil, 0-20, 40-60 and 100-120 cm, and Salinas soil, 0-15 and 115-130 cm. The mass balance method greatly improved precision of sorption measurement on the deep Wahiawa subsoil having the lowest sorption. The coefficient of variation (CV) for $K_d$ measurement was 20.3% for the batch method and 8.4% for the mass balance method. For other soil samples tested, precision of the batch method was relatively high but was still improved by the mass balance method.

  • PDF

Ambient CO2 Measurement Using Raman Lidar (라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정)

  • Kim, Daewon;Lee, Hanlim;Park, Junsung;Choi, Wonei;Yang, Jiwon;Kang, Hyeongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1187-1195
    • /
    • 2019
  • We, for the first time, developed a Raman lidar system which can remotely detect surface CO2 volume mixing ratio (VMR). The Raman lidar system consists of the Nd: YAG laser of wavelength 355 nm with 80 mJ, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar system is calculated to be 99.89%. We carried out the field measurement using our Raman lidar at Pukyong National University over a seven-day period in October 2019. The results show good agreement between CO2 VMRs measured by the Raman lidar (CO2 Raman Lidar) and those measured by in situ instruments (CO2 In situ) which located 300 m and 350 m away from the Raman lidar system. The correlation coefficient (R), mean absolute error (MAE), and root mean square error (RMSE) between CO2 In situ and CO2 Raman Lidar are 0.67, 2.78 ppm, and 3.26 ppm, respectively.

Determination of Bioconcentration Factor on Phosphamidon and Profenofos by Flow-through Fish Test (Flow-through fish test를 이용한 Phosphamidon과 Profenofos의 생물농축계수의 측정)

  • Min, Kyung-Jin;Cha, Chun-Geun;Seo, Seol
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2000
  • The present study was performed to investigate the bioconcentration of phosphamidon and profenofos. The BCFs(bioconcentration factors), depuration rate constants and LC$_{50}$ for two pesticides in zebrafish(Brachydanio rerio) were measured by the flow-through system(OECD guideline 305). The results obtained are summarized as follows: The 24-hrs LC$_{50}$, 48-hrs LC$_{50}$, 72-hrs LC.n and 96-hrs LC$_{50}$ were more than 100 mg/l for phosphamidon. The concentration of phosphamidon in zebrafish reached an equilibrium in 12 hrs at low and high concentrations(0.2 mg/l and 1 mg/1). The average BCF values of phosphamidon were less than 1 at low(0.96, n=7) and high concentrations (0.89, n=7) after 12~168 hrs. Depuration rate constants of phosphamidon were 0.18 hr-1 and 0.21 hr-1, half-life of phosphamidon were 3.85 and 3.30 at low and high concentrations(0.2 mg/l and 1 mg/l), respectively, The concentrations of phosphamidon in zebrafish at low and high concentrations were rapidly decreased after 8(0.04 $\mu\textrm{g}$/g) and 12 hrs(0.07 $\mu\textrm{g}$/g). The 24-hrs LC$_{50}$, 48-hrs LC$_{50}$, 72-hrs LC$_{50}$ and 96-hrs LC$_{50}$ were 2.9, 2.6, 2.2 and 2.0 mg/1 for profenofos. The concentration of profenofos in zebrafish reached an equilibrium in 12 hrs at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$(0.004 mgA and 0.02 mg/1). The average BCF values of profenofos were 141.9(n=7) and 111.3(n=7) at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$(0.004 mg/l and 0.02 mg/1) after 12~168 hrs. Depuration rate constants of profenofos were 0.09 hr$^{-1}$ and 0.10 hr$^{-1}$, half-life of profenofos were 7.70 and 6.93 at five-hundredth and one-hundredth concentration of 96-hrs LC50(0.004 mg/l and 0.02 mg/1), respectively. The concentrations of profenofos in zebrafish at five-hundredth and one-hundredth concentration of 96-hrs LC$_{50}$ decreased agter 8(0.18 $\mu\textrm{g}$/g) and 12 hrs (0.19 $\mu\textrm{g}$/g). The LC$_{50}$ value in zebrafish showed that acute toxicity of profenofos was higher than that of phosphamidon. The BCF values of profenofos were 100 times higher than those of phosphamidon, and depuration rate of phosphamidon was two times faster than that of profenofos.

  • PDF

A Study on Nitric Oxide Formation & Reduction in Industrial Burner (I) -NO Concetration-Distribution in Double Swirling Diffusion Flame by LIF- (산업용 고부하버너 연소에서의 $NO_x$ 형성 및 저감에 관한 연구(I)-레이저 유도 형광법(LIF)를 이용한 이중선회 확산화염의 NO 농도 분포 측정-)

  • 박경석;김경수
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.379-386
    • /
    • 2001
  • This experimental study deals with on Nitric Oxide Formation & Reduction in Industrial Bunner. In this study, Laser-induced fluorescence (LIF) techniques have been used for quantitative measurements of Nitric Oxide. The NO A-X (0, 0) Vibrational band around 226 nm was excited using a XeCl excimer-pumped dye laser. And on-line excitation used $P_{21}+Q_1(14.5)/R_{12}+Q_2(20.5)/P_1(23.5)$ transition, for minimizing the other interferential effect. The measurements were taken NO concentration distribution in double swirling diffusion flame. In this swirl burner, NO concentration in downstream fo the flame decrease as primary/secondary air ratio increases.

  • PDF

Antioxidant and Whitening Activities of Chlorogenic Acid, Quercetin, and Quercitrin from the Fruit of Vaccinum oldhami (정금나무 열매(Fruit of Vaccinum oldhami)의 분리 정제물(클로로겐산, 퀘르세틴 및 퀘르시트린)에 관한 항산화 및 미백활성 검증)

  • Jung-Woo Chae;Min-Jeong Oh;Hyeon-Ji Yeom;Jin-Young Lee
    • Journal of Life Science
    • /
    • v.33 no.2
    • /
    • pp.115-128
    • /
    • 2023
  • The fruit of Vaccinum oldhami was separated and purified to obtain the compounds chlorogenic acid (CA), quercetin (QT), and quercitrin (QR). The electron-donating abilities of CA, QT, and QR at 1,000 ㎍/ml were 91.9%, 89.9%, and 77.4%, respectively QT and QR showed 99.5% and 91.4% ABTS+ radical scavenging ability at a 1,000 ㎍/ml concentration, respectively, and CA showed a 95% ability or higher at 100 ㎍/ml. Regarding tyrosinase inhibitory activity, CA, QT, and QR exhibited 29.5%, 34.7%, and 23.7% efficacy, respectively, at 1,000 ㎍/ml. Regarding the cell viability for melanoma cells (B16F10) assessed through MTT assay, CA, QT, and QR showed cell a viability of 80% or more at 100 ㎍/ml. To measure the deterrent of protein expression, CA affected TRP-1 and TRP-2 in accordance with increases in concentration. The protein expression inhibition rate of QT was excellent for TRP-1, TRP-2, and tyrosinase. CA was confirmed to have an excellent mRNA expression inhibitory effect against MITF, and the amount of mRNA expression of TRP-1, TRP-2, and tyrosinase decreased with an increase in the CA concentration. As the concentration of QT increased, the mRNA expression of MITF, TRP-2, and tyrosinase decreased. QR decreased the amount of mRNA as the QR concentration increased. The excellent antioxidant and whitening effects of CA, QT, and QR were thus confirmed.

재장전노심의 노물리시험중 제어봉제어능 측정방법들에 대한 통계적 추론

  • 정대욱;구본현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.80-87
    • /
    • 1996
  • 국내 가동중원전의 노물리 시험중 제어봉제어능 측정시 적용되는 측정방법들에 대해 실제 측정결과를 이용해서 통계적 분석 및 추론을 수행하였다. 1988년부터 현재까지 약 8년간 모든 발전소에서 행한 측정결과에 대해 통계적 분석 및 주요 시험변수들과의 상관관계를 분석한 결과, 다음과 같은 결론이 도출되었다. 제어봉 제어능 측정결과는 전반적으로 측정치가 예측치에 비해 작은 경향을 보이고 있다. 붕산희석법은 측정오차가 가장 작았고 임의성을 가지며, 노심의 붕산농도와 상관관계가 있다. Framatome방식의 제어봉교환법은 비교적 측정오차가 크나, 시험변수들과의 상관 관계는 가장 미약하다. CE 방식의 제어봉교환법은 Swap 방법 중에는 측정오차가 가장 작고 임의성이 있으나, 붕산농도 및 기준제어군 제어능 측정오차의 크기와 강한 상관관계를 갖는다. Westinghouse 방식의 제어봉교환법은 가장 측정오차가 크며 대부분의 측정결과에서 측정치가 작게 편향되어 있다. 그리고 시험제어군의 제어능이 작을수록 측정오차가 커지는 강한 상관관계가 있으며, 기준제어군 제어능 측정오차의 크기와도 상관관계가 있다.

  • PDF

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Characteristic Analysis and Rating Development of Suspended Sediment Discharge in 2014 (2014년도 부유사량 특성분석 및 레이팅 개발)

  • Park, Yonghee;Lee, Jung Hoon;Kwon, Dongseok;Lee, YeonKil;Jung, SungWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.311-316
    • /
    • 2015
  • 하천 유사량 자료는 하천의 이 치수 목적으로 활용할 수 있는 기본 자료중 하나로서 하상변동 예측, 저수지 퇴사량 추정, 하도 계획과 설계, 유사조절 계획 수립 및 기타 구조물 등의 영향 평가 등 다양하게 활용할 수 있다. 정도 높은 유사량 자료를 측정하기 위해서는 현장측정부터 분석까지 정확한 과정과 세밀한 준비가 필요하다. 본 연구에서는 정도 높은 유사량 자료를 생산하기 위하여 국가 유사량 관측망 중 19개 지점(율극, 점촌, 일선교, 구미, 왜관, 선산, 죽고, 진동, 개진2, 정암, 회덕, 마륵, 나주, 학교, 남평, 영수, 선암, 구례2, 죽곡, 용서, 곡성)에 대하여 부유사량 특성분석을 수행하고 이를 반영하여 유량-부유사량관계곡선식을 개발하였다. 유사량 측정과정은 사전조사, 현장측정, 실험실분석, 모형적용 단계를 거친다. 사전조사 단계에서는 현장에 대한 현장안전, 지점특성 등의 현장관련 정보를 수집하여 현장측정 계획을 수립한다. 현장측정 단계에서는 사전에 유량측정 자료를 이용하여 측선을 나누는 등유량법과 등간격법을 사용하였으며, ISO 기준 이상의 5~8개 측선을 나누어 측정하였다. 측정장비는 D-74 부유사 채취기를 이용하여 왕복수심적분법으로 부유사량 샘플을 채취 하였다. 실험실분석은 유량조사사업단 유사분석센터에서 채취 시료에 대한 농도, 레이저 회절법을 이용한 부유사입도분석, 하상토분석(체분석)을 실시하였다. 또한, 유량-부유사량 농도 변화양상과 부유사량 특성분석을 이용한 부유사량 측정결과를 평가하였고 각 지점의 부유사량특성을 잘 나타낼 수 있는 지수식($Q_{ss}=aQ^b$)을 이용하여 유량-부유사량관 계곡선식을 개발하였다.

  • PDF

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Effect of Phyto-Extract Fermented Mixture (MP119) on the Sexual Functions and on the Toxicities of Cadmium (식물추출복합발효물(MP119)이 성기능에 미치는 영향 및 카드뮴 독성에 대한 효과)

  • Jang, Young-Sun;Jeong, Jong-Moon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1724-1731
    • /
    • 2009
  • This study was aimed to investigate the effect of phyto-extract fermented mixture (MP119) on the male sexual functions. The MP119 was evaluated for anti-impotency and anti-hypertensive effects via ACE (angiotensin converting enzyme) or PDE (phosphodiesterase) inhibition assay. $IC_{50}$ values of MP119 against ACE and PDE were 241.3${\pm}$35.5 ppm and 372.2${\pm}$33.8 ppm, respectively. To investigate the effect of testosterone expression by MP119, we performed cell media test using mouse Leydig-derived TM3 cells. Production of testosterone in TM3 cell was increased by MP119. Also, NO (nitric oxide) production of HUVEC (human umbilical vein endothelial cell) was increased when MP119 was added to the cultures. Forty male ICR mice were divided into 4 groups. MP119 was orally intubated for 7 days to group 1 and 3, and same volume of vehicle to group 2 and 4 as controls. After that, group 3 and 4 were intraperitoneally injected cadmium chloride at a single dose of 2 mg/kg. On the 8th experimental day, weights of testis, epididymis and seminal vesicle, number of sperm, concentrations of serum testosterone and cGMP were determined. The number of sperm, the concentrations of testosterone and cGMP were significantly increased in two experimental groups (group 1, 3). These results suggest that MP119 enhanced the sexual function of male mice, and could protect the sexual organs from the cadmium chloride as one of the endocrine disrupters.