• Title/Summary/Keyword: 논문평가

Search Result 33,878, Processing Time 0.063 seconds

The Study of Dose Distribution according to the Using Linac and Tomotherapy on Total Lymphnode Irradiation (선형가속기와 토모치료기를 이용한 전림프계의 방사선 치료시 선량분포에 관한 연구)

  • Kim, Youngjae;Seol, Gwanguk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.285-291
    • /
    • 2013
  • In this study, compare and analyze the dose distribution and availability of radiation therapy when using a different devices to TNI(Total Lymphnodal Irradiation). Test subjects(patients) are 15 people(Male 7, Female 8). Acquire CT Simulation images of the 15 people using Somatom Sansation Open 16 channel and then acquired images was transferred to each treatment planning system Pinnacle Ver 8.0 and Tomotherapy Planning System and separate the tumor tissue and normal tissues(whole lung, spinal cord, Rt kidney, Lt kidney). Tumor prescription dose was set to 750 cGy. and then Compare the Dose Compatibility, Normal Tissue's Absorbed Dose, Dose Distribution and DVH. Statistical analysis was performed SPSS Ver. 18.0 by paired sample Assay. The absorbed dose in the tumor tissue was $751.0{\pm}4.7cGy$ in tomotherapy planning, $746.9{\pm}14.1cGy$ in linac. Tomotherapy's absorbed dose in the tumor was more appropriate than linac. and These values are not statistically significant(p>0.05). Tomotherapy plan's absorbed dose in the normal tissues were less than linac's plan. This value was statistically significant(p<0.05) excepted of whole lung. In DVH, appropriated on tumor and normal tissues in tomotherapy and linac but tomotherapy's TER was better than linac. Namely, a result of Absorbed dose in tumor and normal tissue, Dose distribution pattern, DVH, Both radiation therapy devices were appropriated in radiation therapy on TER. The Linac has a short treatment time(about 15-20 min) and open space on treatment time. It cause infant and pediatric patients to receiving uncomfortable treatment. So, In this case, it will be fine that Linac based therapy was restricted use. and if the patient was cooperative, it will be show a better prognosis that Tomotherapy using Radiation Therapy.

A Survey for Changed Control Policies of Hepatitis B in Republic of Korea (우리나라의 B형 간염 조절 정책의 변화에 대한 조사)

  • Han, Ji Yoon;Jung, Tae Woong;Koh, Dae Kyun;Kim, Jong Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.124-134
    • /
    • 2011
  • Purpose : We have tried to search all concerning data on the policies of hepatitis B vaccination or surveillance of medical equipments that can transmit blood mediated diseases, including disposable syringe, in Republic of Korea, to propose references to other medical professionals. Methods : Data from domestic journals, government websites, computerized newspapers, etc. were reviewed. The data were arranged into four categories (governmental policies on hepatitis B control, hepatitis B mass immunization program in school, using process of hepatitis B vaccine, and policies on medical equipments surveillance, including disposable syringes, which is considered as source of blood mediated infection), and the periodic changes on each subjects in policies were reviewed. Results : Due to growing social concerns on hepatitis B in early 1980s, swift introduction and production of hepatitis B vaccine was made. After establishment of "5 year project for eradication of hepatitis B" in late 1983, number of vaccinated population jumped up to 6 million within 2 years (1984-85). However, since the immunization targets were mainly adult, not infant, this project was annulled in late 1985. Following this project, hepatitis B mass immunization program in school was carried out. In year 1995, hepatitis B vaccine was included in national immunization program. The use of disposable syringe was recommended from year 1980 but legislated in year 1985, finally. Conclusion : The mainstay in controlling hepatitis B in Republic of Korea was coordination of prompt introduction of vaccine, mass immunization, high vaccination coverage rate, or use of disposable syringes. However, since there is lack of official data available, it is urgent to arrange and computerize all government data related to infectious diseases.

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

An Oceanic Current Map of the East Sea for Science Textbooks Based on Scientific Knowledge Acquired from Oceanic Measurements (해양관측을 통해 획득된 과학적 지식에 기반한 과학교과서 동해 해류도)

  • Park, Kyung-Ae;Park, Ji-Eun;Choi, Byoung-Ju;Byun, Do-Seong;Lee, Eun-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.234-265
    • /
    • 2013
  • Oceanic current maps in the secondary school science and earth science textbooks have played an important role in piquing students's inquisitiveness and interests in the ocean. Such maps can provide students with important opportunities to learn about oceanic currents relevant to abrupt climate change and global energy balance issues. Nevertheless, serious and diverse errors in these secondary school oceanic current maps have been discovered upon comparison with up-to-date scientific knowledge concerning oceanic currents. This study presents the fundamental methods and strategies for constructing such maps error-free, through the unification of the diverse current maps currently in the textbooks. In order to do so, we analyzed the maps found in 27 different textbooks and compared them with other up-to-date maps found in scientific journals, and developed a mapping technique for extracting digitalized quantitative information on warm and cold currents in the East Sea. We devised analysis items for the current visualization in relation to the branching features of the Tsushima Warm Current (TWC) in the Korea Strait. These analysis items include: its nearshore and offshore branches, the northern limit and distance from the coast of the East Korea Warm Current, outflow features of the TWC near the Tsugaru and Soya Straits and their returning currents, and flow patterns of the Liman Cold Current and the North Korea Cold Current. The first draft of the current map was constructed based upon the scientific knowledge and input of oceanographers based on oceanic in-situ measurements, and was corrected with the help of a questionnaire survey to the members of an oceanographic society. In addition, diverse comments have been collected from a special session of the 2013 spring meeting of the Korean Oceanographic Society to assist in the construction of an accurate current map of the East Sea which has been corrected repeatedly through in-depth discussions with oceanographers. Finally, we have obtained constructive comments and evaluations of the interim version of the current map from several well-known ocean current experts and incorporated their input to complete the map's final version. To avoid errors in the production of oceanic current maps in future textbooks, we provide the geolocation information (latitude and longitude) of the currents by digitalizing the map. This study is expected to be the first step towards the completion of an oceanographic current map suitable for secondary school textbooks, and to encourage oceanographers to take more interest in oceanic education.

Contribution of Oswald Veblen to AMS and its meaning in Korea (Oswald Veblen이 미국수학계에 미친 영향과 한국에서의 의미)

  • Lee, Sang-Gu;Ham, Yoon-Mee
    • Journal for History of Mathematics
    • /
    • v.22 no.2
    • /
    • pp.27-52
    • /
    • 2009
  • This article discusses the contributions of the leader Oswald Veblen, who was the president of AMS during 1923-1924. In 2006, Korea ranked 12th in SCIE publications in mathematics, more than doubling its publications in less than 10 years, a successful model for a country with relatively short history of modern mathematical research. Now there are 192 four-year universities in Korea. Some 42 of these universities have Ph.D. granting graduate programs in mathematics and/or mathematical education in Korea. Rapid growth is observed over a broad spectrum including a phenomenal performance surge in International Mathematical Olympiad. Western mathematics was first introduced in Korea in the 17th century, but real significant mathematical contributions by Korean mathematicians in modern mathematics were not much known yet to the world. Surprisingly there is no Korean mathematician who could be found in MaC Tutor History Birthplace Map. We are at the time, to have a clear vision and leadership for the 21st century. Even with the above achievement, Korean mathematical community has had obstacles in funding. Many people thinks that mathematical research can be done without funding rather unlike other science subjects, even though they agree fundamental mathematical research is very important. We found that the experience of early American mathematical community can help us to give a vision and role model for Korean mathematical community. When we read the AMS Notice article 'The Vision, Insight, and Influence of Oswald Veblen' by Steve Batterson, it answers many of our questions on the development of American mathematics in early 20th century. We would like to share the story and analyze its meaning for the development of Korean Mathematics of 21st century.

  • PDF

Distribution characteristics of chemical oxygen demand and Escherichia coli based on pollutant sources at Gwangyang Bay of South Sea in Korea (남해 광양만에서 오염원에 따른 화학적 산소요구량과 대장균의 해역별 분포특성)

  • Baek, SeungHo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3279-3285
    • /
    • 2014
  • This study aimed to understand seasonal and geographical characteristic of chlorophyll-${\alpha}$ (chl-${\alpha}$), COD (chemical oxygen demand) and Escherichia coli at Gwangyang Bay during the period from February 2010 to November 2012. The bay is divided into three different zones based on the pollutant levels and geographical characteristics. During the study periods, water temperature, salinity, Chl. ${\alpha}$, and chemical oxygen demand (COD) varied in the range of $4.68-28.63^{\circ}C$, 1.94-33.84 psu, 0.31-35.10 ${\mu}gL^{-1}$, and 0.70-13.35 $mgL^{-1}$, respectively. Total chl-a concentration were high at the zone I, which can be characterized as a semi-enclosed eutrophic area, and it were low at the zone III, which is influenced by low nutrients of surface warm water current from offshore of the bay. The high concentration of COD was observed at inner bay during the four seasons and the water quality level was kept to be bad condition during spring season at the zone II, which is influenced by Seomjin River water. The highest colony form of E. coli was recorded to be 3550 $cfuL^{-1}$ during summer at station 1 (zone I), whereas it was relatively kept low level during all seasons at the zone III. As a result, the E. coli was correlated with water temperature (r=0.31 p<0.05) and salinity (r=-0.55 p<0.05), implying that those parameters have play an important crucial role in proliferation of E. coli. Consequently, our results indicated that the E. coli can be significantly promoted within pollutant sources including the high nutrients supplied by rive discharge during spring and summer rainy seasons in semi-enclosed area of Gwangyang Bay.

Pain Reduction Effects of Lidocaine Gel for Urethral Catheterization : A Systematic Review and Meta-Analysis (요도 카테터 삽입술에서 리도카인 윤활제의 통증 감소 효과 : 체계적 문헌고찰과 메타분석)

  • Hong, Hyun-Jung;Kim, Ga-Eun;Lee, Ha-Nee;Lee, A-Reum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.438-448
    • /
    • 2017
  • This study was a systematic review and meta-analysis that evaluated the results of research on the pain reduction effects of lidocaine gel for urethral catheterization in adults. A literature search was conducted using seven electronic databases, gray literature and other resources based on the guidelines of Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA). A Risk of Bias (RoB) tool was applied to assess the quality of selected studies. Data were analyzed using the RevMan 5.3.-program. Sixteen randomized controlled trials involving 1904 adults were included. RoB was not observed in the funnel plot. Overall, lidocaine gel was effective for pain reduction during urethral catheterization (Standard Mean Difference[SMD] -0.96;95% CI: -1.43, -0.49). To explore the cause of heterogeneity (I2=95%, p<.001), subgroup analysis was conducted according to three catheter types (urinary catheter, flexible cystoscopy, and rigid cystoscopy) and the SMDs were -0.88 (95% CI:-1.51, -0.26), -0.31 (95% CI:-0.63, 0.01), and -1.93 (95% CI:-2.88, -0.97), respectively. A significant pain reduction effect was observed regardless of gender in urinary catheterization. However, in rigid cystoscopy, a significant pain reduction effect was observed only in male subjects. Pain reduction effects were observed when 10~11ml lidocaine gel was used during rigid cystoscopy and when lubrication was used during urinary catheterization, irrespective of application time. These findings suggest that lidocaine gel is a useful anesthetic lubricant for urinary catheterization and rigid cystoscopy in male adults.

Reliability of a Cobalt Silicide on Counter Electrodes for Dye Sensitized Solar Cells (코발트실리사이드를 이용한 염료감응형 태양전지 상대전극의 신뢰성 평가)

  • Kim, Kwangbae;Park, Taeyeul;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2017
  • Cobalt silicide was used as a counter electrode in order to confirm its reliability in dye-sensitized solar cell (DSSC) devices. 100 nm-Co/300 nm-Si/quartz was formed by an evaporator and cobalt silicide was formed by vacuum heat treatment at $700^{\circ}C$ for 60 min to form approximately 350 nm-CoSi. This process was followed by etching in $80^{\circ}C$-30% $H_2SO_4$ to remove the cobalt residue on the cobalt silicide surface. Also, for the comparison against Pt, we prepared a 100 nm-Pt/glass counter electrode. Cobalt silicide was used for the counter electrode in order to confirm its reliability in DSSC devices and maintained for 0, 168, 336, 504, 672, and 840 hours at $80^{\circ}C$. The photovoltaic properties of the DSSCs employing cobalt silicide were confirmed by using a simulator and potentiostat. Cyclic-voltammetry, field emission scanning electron microscopy, focused ion beam scanning electron microscopy, and energy dispersive spectrometry analyses were used to confirm the catalytic activity, microstructure, and composition, respectively. The energy conversion efficiency (ECE) as a function of time and ECE of the DSSC with Pt and CoSi counter electrodes were maintained for 504 hours. However, after 672 hours, the ECEs decreased to a half of their initial values. The results of the catalytic activity analysis showed that the catalytic activities of the Pt and CoSi counter electrodes decreased to 64% and 57% of their initial values, respectively(after 840 hours). The microstructure analysis showed that the CoSi layer improved the durability in the electrolyte, but because the stress concentrates on the contact surface between the lower quartz substrate and the CoSi layer, cracks are formed locally and flaking occurs. Thus, deterioration occurs due to the residual stress built up during the silicidation of the CoSi counter electrode, so it is necessary to take measures against these residual stresses, in order to ensure the reliability of the electrode.