Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings - (교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 -)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

The Improvement of Building Envelope Performance in Existing School Building (기존 학교 건물의 외피 성능 개선 방안에 관한 연구)

  • Bang, Ah-Young;Park, Se-Hyeon;Kim, Jin-Hee;Kim, Young-Jae;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: This study is to investigate the effects of facade insulation and window remodeling of an existing old middle school building on the reduction of energy consumption. Method: To analyze energy performance of building, using DesignBuilder v3.4, building energy simulation tool based EnergyPlus engine. Energy consumption and problem of target building was analyzed based on data and survey. Based on building energy simulations it analyzed the variation of energy demand for the building according to U-value of wall, glazing properties and external shading devices. Result: When insulation of building was reinforced, cooling and heating load was decreased. Glazing properties that minimize cooling and heating energy consumption were analyzed. In conclusion, it is important to choose SHGC and U-value of window fit in characteristic of target building. Setting external blind for cooling load decreases 5%.