• Title/Summary/Keyword: 냉방 및 제습

Search Result 27, Processing Time 0.027 seconds

Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse (냉수파이프에 의한 온실의 제습 및 증발냉각효율)

  • 김문기;남상운;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.237-245
    • /
    • 1998
  • Greenhouse crop production under critical summer climate In Korea has considerable difficulties because of high temperature and relative humidity. In this study, some water pipes were tested as a means of the dehumidification and increment of evaporative cooling efficiency. As a result of heat transfer characteristic analysis, overall heat transfer coefficient of copper pipe was larger than steel pipe, and estimated values were smaller than measured values. The condensed quantities of vapor were not significantly different between copper pipe and steel pipe, however dehumidifying effect by the water pipes was significantly large. It was estimated based on the results that the evaporative cooling system by the water pipe will be able to increase the evaporative cooling efficiency of about 48%, and decrease the temperature of about 1.3$^{\circ}C$.

  • PDF

Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System (건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석)

  • IN, JUNGHYUN;LEE, YULHO;KANG, SANGGYU;PARK, SUNGJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

Dehumidification and Increment of Efficiency of Evaporative Cooling in Greenhouse with Water Pipe (냉수배관에 의한 온실의 제습 및 증발냉각효율 증대효과)

  • 김문기;남상운;윤남규
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.10a
    • /
    • pp.103-106
    • /
    • 1995
  • 최근 시설재배 면적이 급증하고 있는 것에 부응하여 시설을 이용한 작물의 주년안정생산에 관한 연구가 활성화되고 있다. 그러나 여름철의 고온극복과 냉방에 관한 연구는 아직까지도 많은 어려움을 겪고 있다. 우리나라와 같이 사계절이 뚜렷한 기후여건에서는 겨울철의 난방 및 보온에 못지 않게 여름철의 냉방 및 고온극복 대책이 주년안정생산에 있어서 빼놓을 수 없는 중요한 과제가 아닐 수 없다. (중략)

  • PDF

Prediction on heat and mass transfer coefficients in a packed layer of a regenerator with a solar desiccant cooling system (태양열제습냉방시스템 중 재생기의 충진층 내 열물질 전달계수에 관한 예측)

  • Eflita, Yohana;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.36-42
    • /
    • 2010
  • 본 논문은 태양열이용 냉난방시스템 중에서 실제로 액체흡수제를 재생하는 재생탑 내의 충진층에 있어서의 열 및 물질전달의 실험치와 이론적 해석에 의한 결과치와의 비교를 나타내고 있다.특히 물질전달의 극대화를 위하여 충진층 내에서 공기와 흡수제의 접촉면적을 크게 할 필요가 있는데,이를 위해서 본 실험에서는 직경이 3cm인 플라스틱제 충진재를 사용하였으며, 흡수제로는 저농도의 염화리튬 수용액이 사용 되었다. 충진층 내에서의 최적 높이를 예측하기 위하여 해석의 모델인 실험장치를 직접 제작하여 실험을 수행하였고, 이론 해석에 있어서 체적 열전달을 고려한 정상상태를 모델화하여 해석하였다. 이 결과, 충진층 내에서 실험치와 이론적인 계산치가 잘 일치함을 알 수 있었으며, 충진층의 높이가 2m 이상인 경우에는 높이에 따른 재생량의 차이가 없어서 없음을 알 수 있었다.

Solar Cooling Technology (태양열 냉방 시스템)

  • Baek, Nam-Choon
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.31-49
    • /
    • 1998
  • Four main solar cooling technologies have been developed over the past twenty years are considered in this paper. These technologies include absorption, vapor compression, desiccant, adsorption, etc. All of these solar cooling technologies considered here are solar thermal ones. The destails of the thermodynamic cycle of these solar cooling technologies are given. The general concept of these solar cooling and the relative advantages among them are also presented. At last, the status and outlook for each approach are summarized.

  • PDF

Experimental Study on Development of Air Leakage Model and Performance Characteristics of a Desiccant Rotor (제습로터의 공기누설모델 개발 및 성능 특성에 관한 실험적 연구)

  • Kang, Byung-Ha;Pi, Chang-Hun;Chang, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • This study investigates the pressure leakage characteristics of a desiccant rotor with a brush-type air seal. Through a pressure leakage experiment, a correlation equation for the leakage air flow rate is obtained as a function of the air seal area and pressure difference. Using this equation, an air leakage model for the desiccant rotor is developed. By comparing simulation results with the experimental results for the desiccant rotor, the accuracy of the air leakage model is demonstrated. A performance test of a desiccant rotor with various air flow rates is carried out. Using the air leakage model, the effective mass flow rate and air leakage rate are found. In addition, the characteristics of the air leakage are analyzed for a desiccant cooling system using the developed air leakage model.

Dehumidification by refrigeration (냉각식 제습)

  • 송영환
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.27 no.6
    • /
    • pp.548-552
    • /
    • 1998
  • 일반적으로 공기조화에 대하여 이야기할 때 온도조건은 중요하게 생각하고 습도는 부수적인 요소로 생각해버리는 경향이 있다. 그러나 습도는 공조시스템을 구성하는데 필요한 다른 요소들과 함께 매우 중요한 요소이며 산업 분야에 따라서는 최우선적으로 고려되어야 할 사항중의 하나이다. 실제로 습도는 철강류와 곡식의 저장 및 병원의 수술실을 비롯하여 제약과 반도체 산업 및 섬유의 제조공정 등의 분야에서 중요하게 다루어지고 있으며 여타 분야에서도 냉방장치의 보급과 더불어 온도에 대한 욕구가 충족되면서 습도에 대한 관심이 늘어나고 있다.

  • PDF

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System (태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구)

  • Yohana, Eflita;Choi, Kwang-Hwan;Kim, Bu-Ahn;Kim, Dong-Gyu;Paek, Ki-Dong;Kim, Ji-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

An Experimental and Numerical Analysis on Performance Comparison of a Trigeneration Desiccant System and Conventional Air-conditioning System (Trigeneration 제습공조시스템과 일반공조시스템의 성능 비교 실험 및 수치해석)

  • Kim, Hyoung-Tae;Chae, Jungmin;Cho, Young-Ah;Park, So-jin;Song, Geun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.32-37
    • /
    • 2018
  • Recently, the distributed power generation market using natural gas is expected to expand gradually according to the government's future energy conversion policy. Distributed power generation means small power generation source near the power demand site, which has the advantage of reducing the construction costs of the transmission and distribution infrastructure, operating cost and power loss. A typical example of distributed generation using natural gas is the trigeneration system. In this study, we conducted a basic study on the performance analysis of trigeneration desiccant system for dehumidifying / cooling / heating in the air conditioner room by using the cold and engine waste heat energy generated in the trigeneration system. It shows that the system efficiency increases and the energy consumption decreases as the temperature difference between the inlet and outlet of the trigeneration system increases compared with the general air conditioning system.