지중열원 열펌프시스템의 성능해석 (A Study on the Performance of Ground Source Heat Pump System)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

수직형 지열히트펌프 시스템의 육묘 온실 냉방 효과 분석 (Analysis on Cooling Effects of the Vertical Type Geothermal Heat Pump System Installed in a Greenhouse for Raising Seedling)

  • 강연구;유영선;김종구;김영화;장재경
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.19-25
    • /
    • 2013
  • 본 연구에서는 농가현장에 보급되어 있는 350kW (175kW ${\times}$ 2대)급 수직형 지열히트펌프시스템으로 $1,650m^2$ 면적의 육묘온실에 2011년 6월 7일부터 9월 18일까지 냉방실험을 수행하여 냉방성능을 분석하고, 농가현장에서 지열히트펌프를 가동함에 있어 보다 효과적인 운용방법을 고려해보고자 하였다. 증발기측 물 온도차는 증발기 입구 물온도가 $26.4^{\circ}C$에서 $17.1^{\circ}C$로 변할 때 최대 $1.7^{\circ}C$, 최소 $0.9^{\circ}C$ 차이(평균 $1.3^{\circ}C$)를 보였으며, 증발기 입구 물온도가 $16.6^{\circ}C$에서 $13.1^{\circ}C$로 변할 때 최대 $1.1^{\circ}C$, 최소 $0.8^{\circ}C$($0.9^{\circ}C$) 차이를 보였다. 히트펌프를 1대(175kW ${\times}$ 1대) 가동하는 경우, 증발기 입구에 유입되는 물온도 $13.0{\sim}15.5^{\circ}C$(응축기 입구에 유입되는 물온도 $19.4{\sim}21.2^{\circ}C$) 범위에서 냉방성능계수는 1.1~1.8, 발생한 냉방열량은 68.2~106.8kW, 소비전력은 61.0kW, 히트펌프를 2대(175kW ${\times}$ 2대) 가동하는 경우, 증발기 입구 물온도 $10.0{\sim}13.0^{\circ}C$(응축기 입구에 유입되는 물온도 $18.5{\sim}22.2^{\circ}C$) 범위에서 냉방성능계수는 2.0~2.7, 냉방열량은 203.9~262.0kW, 소비전력은 95~98kW 이었다. 6월의 누적 냉방열량은 14,718.6kWh(12,657,996kcal), 누적소비전력은 6,352.0kWh이었으며, 7월은 각각 26,765.1, 11,600.0kWh, 8월은 각각 28,437.2, 12,508.0kWh, 9월은 10,065.0, 5,125.0kWh로 8월이 가장 큰 냉방열량을 나타내었다.

산화 그래핀 나노유체의 파울링 현상에 따른 시스템의 안전성에 대한 연구

  • 강혜원;김효석;김남진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.382.1-382.1
    • /
    • 2016
  • 비등 열전달 시스템은 각종 발전 시스템, 열교환기, 냉방 및 냉동 시스템과 같이 다양한 산업에서 이용되며 매우 중요시 되고 있다. 또한 비등 열전달 시스템에서의 임계 열유속은 열전달 시스템의 한계 및 안정성을 나타내는 중요한 인자이다. 따라서 비등 열전달 시스템의 성능을 높이기 위해 임계 열유속을 향상시키려는 연구 및 개발이 지속적으로 이루어지고 있다. 최근에는 작동유체를 나노유체로 사용할 경우 임계 열유속을 크게 향상 시킬 수 있다고 보고되었다. 하지만 작동유체를 나노유체로 사용할 경우 나노입자가 열전달 표면에 침착되는 현상을 유발하며 열전달 시스템의 성능을 감소시킬 수 있다. 따라서 본 연구에서는 산화 처리된 그래핀 나노유체의 파울링 현상에 따른 열적 특성을 분석해 보았다. 그 결과 산화 처리된 그래핀 나노 파울링은 유속과 파울링을 위한 코팅시간이 증가할수록 산화 처리된 그래핀 나노유체의 임계 열유속이 크게 증가하고 있음을 확인할 수 있었다. 하지만 임계 열유속은 증가하나 비등 열전달 표면의 온도가 크게 증가하고 있음을 확인하였다. 그리고 열전달 계수는 유동이 없는 순수 물 비등 열전달 계수와 비교하여 감소하는 것으로 나타났다.

  • PDF

플래쉬 중각냉각기와 플래쉬 가스 바이패스를 이용한 이단압축 이산화탄소 사이클의 냉방성능에 관한 해석적 연구 (Simulation Study on the Cooling Performance of the Two-Stage Compression CO2 Cycle with the a Flash Intercooler and Flash Gas Bypass)

  • 곽명석;조홍현
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.17-24
    • /
    • 2012
  • 본 연구에서는 효율적인 냉방시스템의 성능특성을 연구하기 위하여 2단압축을 이용한 이산화탄소 냉방사이클의 성능에 대하여 해석적 연구를 진행하였다. 2단압축을 이용한 플래쉬 중간냉각(flash intercooler)과 플래쉬 가스 바이패스(flash gas bypass) 사이클에 대한 해석적 모델을 개발하였으며 실내온도, 실외온도, 그리고 1단 및 2단 EEV 개도를 변화시켰다. 그 결과 FI와 FGB 사이클의 성능계수는 실외온도를 변화시켰을 경우 각각 28.5%, 22.1% 정도 감소하였으며, 실내온도 변화에 따른 이단압축 사이클의 성능변화는 단단압축 사이클에 비하여 적은 것으로 나타났다. 또한 저단 및 고단 EEV 개도를 변경하였을 경우 성능은 각각 13.5%, 6.9% 그리고 0.9%, 2.6% 정도 증가하는 것으로 나타나 고단 EEV 개도보다 저단의 EEV 개도의 변화가 시스템의 성능에 미치는 영향이 큰 것으로 확인되었다. FI 사이클은 다양한 운전조건에서 시스템의 성능이 가장 높게 나타나는 것을 확인할 수 있었다.

열펌프 유닛 성능과 지열원 냉난방 시스템 설계에 관한 연구 (Optimum Design of the Ground-Coupled Heat Pump Systems according to Heat Pump Unit Performance)

  • 김남태;조찬용;최종민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.193-193
    • /
    • 2011
  • 현재까지 대부분의 지열원 열펌프 시스템에 관한 연구는 열펌프 유닛과 지중열교환기에 대해 개별적으로 수행되었으며, 열펌프 유닛과 지중열교환기 설계 및 최적화의 공통변수인 지중순환수 유량에 따른 시스템 전체에 대한 연구성과는 매우 미미한 실정이다. 본 연구에서는 현재 국내에서 인증되어 보급되고 있는 물매물 지열원 열펌프 유닛의 성능 자료를 분석하고, 지중순환수 유량 변화에 따른 물대물 열펌프 유닛의 성능 실험 및 지중열교환기 형상에 관한 설계 및 분석을 수행하여 지열원 열펌프 시스템 최적화에 관한 기반 기술 확보하고자 하였다. 현재 국내의 물대물 지열원 열펌프 유닛의 냉방 및 난방 조건에서의 최소 인증 COP는 각각 4.1과 3.45이다. 다양한 용량 및 성능을 갖는 국내 인증 물대물 지열원 열펌프 유닛에 대한 정량적 성능 분석을 위하여 3.5kW(1RT) 용량당의 지중순환수 유량과 COP를 고찰하였다. 냉방운전시 3.5kW 단위 용량당 열펌프 유닛의 지중순환수 유량은 10.73에서 18.52LPM을 나타냈으며, 난방운전에는 10.41에서 18.16LPM을 나타냈다. 이때, 냉방 COP는 4.1에서 5.4의 값을 나타냈으며, 난방 COP는 각각 3.5에서 4.2를 나타냈다. 인증 열펌프 유닛에서 지중순환수 유량과 열펌프 유닛의 냉난방 성능은 일정한 경향성을 나타내지 않았다. 지중순환수 유량에 따른 지열원 열펌프 유닛과 시스템의 성능을 정량적으로 분석하고자 지중순환수 유량 변화에 따른 물대물 지열원 열펌프 유닛 성능 실험을 수행하고 이를 기반으로 지중열교환기를 설계 및 분석하였다. 냉난방 각 운전모드에서 ISO 13256-2 규격과 NRGT 101 규격을 기준으로 지중순환수와 부하측 유량 6LPM 에서 36LPM 사이에서 변화시키며 성능 실험을 수행하였다. 냉방 및 난방모드 모두 유량이 증가함에 따라 열펌프 유닛 COP가 증가하였으나, 유량 증가에 따른 열펌프 유닛 COP 증가율은 감소하였다. 지중순환수 유량이 18LPM 이상에서는 COP 상승폭은 미소하였다. 기존문헌의 부하 산정자료와 열펌프 유닛 실험 성능 데이터를 이용하여 지식경제부 고시 2009-332호에 준하여 수직밀폐형 지중열교환기를 설계하고 순환펌프 소요동력을 이용하여 시스템 COP를 분석하였다. 지중열교환기 설계 시 국내에서 가장 많이 사용되고 있는 상용지중열교환기 설계프로그램인 GLD 프로그램을 사용하였다. 지중순환수와 부하측 2차 유체 유량 증가 시에 열펌프 유닛 COP 증가율 대비 시스템 COP 증가율은 감소하였으며, 난방모드에서는 일정 유량 이상에서는 열펌프 유닛 COP는 증가하였으나, 시스템 COP는 감소하였다. 또한, 지중순환수 유량 증가에 따라 지중열교환기 길이가 증가하였으며, 냉난방시의 지중열교환기 길이차이가 증가하였다. 지열원 열펌프 시스템의 고효율화 및 시공비 절감을 통한 경제성 확보를 위해서는 지열원 열펌프 유닛 성능과 지중열교환기 형상 공통 변수인 지중순환수 유량을 함께 고려하여 시스템을 설계하여야한다.

  • PDF

물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구 (Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System)

  • 홍부표;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

소형 암모니아 흡수식 냉난방기의 냉방성능 특성 (The Characteristics of Heating Performance on Small Sized Ammonia Absorption System)

  • 진병주;오승택;윤정인;황준현;진심원;경익수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.198-202
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

혼합냉매를 사용한 열펌프 시스템의 성능과 열전달 특성 (Performance and Heat Transfer Characteristics of Heat Pump System Using Refrigerant Mixtures)

  • 김동섭;신지영;노승탁
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.360-369
    • /
    • 1992
  • A heat pump system is constructed to evaluate its performance and heat transfer characteristics with mixtures of R22/R142b as working fluids. The heat transfer in the evaporator and the overall performance are measured and analyzed in terms of the compositions and relevant variables. Possibility of capacity modulation by changing composition is observed without degradation of heat transfer coefficients and coefficient of performance. The cooling capacity is varied continuously within 200 percent based on minimum capacity at constant compressor speed. For similar cooling capacity, COP is improved by mixing two refrigerants and shows maximum value at 60% mass fraction of R22. Average heat transfer coefficients of mixtures decrease in comparison with pure refrigerants at similar cooling capacity and mass flow rate. However, the overall heat transfer coefficients decrease moderately. A cycle simulation is performed in order to manifest the advantages of using refrigerant mixtures, considering experimentally observed heat transfer characteristics.

  • PDF

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.

ISO 성능데이터를 이용한 지열히트펌프 시스템의 성능 확인 커미셔닝 기술 (ISO performance data based commissioning technique for GSHP system)

  • 고건혁;김지영;강은철;장기창;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제4권2호
    • /
    • pp.1-7
    • /
    • 2008
  • GSHP(Ground Source Heat Pump) has been extensively disseminated due to the recent increasing demand over new and renewable energy. However, the system reliability has been key issues and barriers to insure a better system performance as designed originally in ISO (international standard organization) standard. This paper introduces a systematic method to verify its intended design target so called as ISO performance data based commissioning technology for a water to air GSHP system. The commissioning technology starts from are to the international standard ISO performance data of a GSHP model and to compare its installed operation data and to calibrate and tune to the target optimum operation parameters. Results indicated that cooling capacity could be raised up to 76.6% from 46.6% from this proposed commissioning technology.