멀티형 냉방시스템의 압축기 제어 (Compressor Control of a Multi-type AIr Conditioning System)

  • 한도영;권형진
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF

텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어 (Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system)

  • 한도영;김재현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향 (Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season)

  • 최영하;이재한;박동금;권준국;엄영철
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 학술발표논문집
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

텐덤형 냉방시스템의 압축기와 전자팽창밸브 제어 (Control of Compressor and Electronic Expansion Valve for a Tandom-type Air-conditioner)

  • 정남철;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.469-473
    • /
    • 2005
  • Capacities of a tandom-type air-conditioner may be modulated by turning on/off multiple compressors and adjusting positions of a electronic expansion valve. In this study. control algorithms for compressors and a electronic expansion valve were developed by using fuzzy’ logics. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature.

  • PDF

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

고온기 근권 냉방방식에 따른 냉방효율과 토마토 생육에 미치는 영향 (Cooling Efficiency and Growth of Tomato as effected by Root-zone Cooling Methods in Summer Season)

  • 이재한;권오근;최영하;박동금;권준국
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1999년도 학술발표논문집
    • /
    • pp.130-133
    • /
    • 1999
  • 우리나라의 시설재배는 비가림 형태에서 많은 자본과 기술이 투자된 현대화 고정시설로 발전해가고 있으며 면적도 증가하고 있다. 시설의 활용면에서는 주로 동절기에 집중되어 있고, 하절기에는 최고기온이 3$0^{\circ}C$ 이상되는 날이 2-3개월 정도로 시설내 작물재배는 거의 불가능한 실정이다. 따라서 하절기에는 대부분 휴작함으로서 시설의 주년이용에 문제점으로 대두되고 있다. (중략)

  • PDF

고온기 근권냉방방식에 따른 냉방효과와 토마토 생육 (Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season)

  • 이재한;권준국;권오근;최영하;박동금
    • 생물환경조절학회지
    • /
    • 제11권2호
    • /
    • pp.81-87
    • /
    • 2002
  • 근권냉방 방식에 따른 냉방 효율과 토마토 생육 특성을 검토하고자 XL냉수순환, 라디에이타 냉풍, 패드냉풍 및 대조구를 처리한 결과는 다음과 같다. 근권부 냉방온도는 공급수온이 17.8$^{\circ}C$일 때 XL 냉수순환구는 18.$0^{\circ}C$ 라디에이타 냉풍구는 27.2$^{\circ}C$, 패드 냉풍구는 20.3$^{\circ}C$였다. 배지 깊이와 시간대별 평균온도는 XL냉수순환구 22.8~24.7$^{\circ}C$. 라디에이타 냉풍구 22.7~24.2$^{\circ}C$, 패드 냉풍구 20.5~23.2$^{\circ}C$, 대조구 25.9~29.6$^{\circ}C$를 나타내어 냉방처리구가 대조구에 비해 5~6$^{\circ}C$더 낮았다. 토마토의 생육에 있어 엽장. 엽폭은 대조구에 비해 컸으며, 생체중 및 건물중의 경우에서도 비슷한 경향이었다 근활력에 있어 대조구는 45.0ug/g에 비해 근권냉방 처리구는 58.5-62.8 ug/g으로 높았으나. 근권냉방 처리구간에는 큰 차이가 없었다.

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

수직형 지열히트펌프 시스템의 육묘 온실 냉방 효과 분석 (Analysis on Cooling Effects of the Vertical Type Geothermal Heat Pump System Installed in a Greenhouse for Raising Seedling)

  • 강연구;유영선;김종구;김영화;장재경
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.19-25
    • /
    • 2013
  • 본 연구에서는 농가현장에 보급되어 있는 350kW (175kW ${\times}$ 2대)급 수직형 지열히트펌프시스템으로 $1,650m^2$ 면적의 육묘온실에 2011년 6월 7일부터 9월 18일까지 냉방실험을 수행하여 냉방성능을 분석하고, 농가현장에서 지열히트펌프를 가동함에 있어 보다 효과적인 운용방법을 고려해보고자 하였다. 증발기측 물 온도차는 증발기 입구 물온도가 $26.4^{\circ}C$에서 $17.1^{\circ}C$로 변할 때 최대 $1.7^{\circ}C$, 최소 $0.9^{\circ}C$ 차이(평균 $1.3^{\circ}C$)를 보였으며, 증발기 입구 물온도가 $16.6^{\circ}C$에서 $13.1^{\circ}C$로 변할 때 최대 $1.1^{\circ}C$, 최소 $0.8^{\circ}C$($0.9^{\circ}C$) 차이를 보였다. 히트펌프를 1대(175kW ${\times}$ 1대) 가동하는 경우, 증발기 입구에 유입되는 물온도 $13.0{\sim}15.5^{\circ}C$(응축기 입구에 유입되는 물온도 $19.4{\sim}21.2^{\circ}C$) 범위에서 냉방성능계수는 1.1~1.8, 발생한 냉방열량은 68.2~106.8kW, 소비전력은 61.0kW, 히트펌프를 2대(175kW ${\times}$ 2대) 가동하는 경우, 증발기 입구 물온도 $10.0{\sim}13.0^{\circ}C$(응축기 입구에 유입되는 물온도 $18.5{\sim}22.2^{\circ}C$) 범위에서 냉방성능계수는 2.0~2.7, 냉방열량은 203.9~262.0kW, 소비전력은 95~98kW 이었다. 6월의 누적 냉방열량은 14,718.6kWh(12,657,996kcal), 누적소비전력은 6,352.0kWh이었으며, 7월은 각각 26,765.1, 11,600.0kWh, 8월은 각각 28,437.2, 12,508.0kWh, 9월은 10,065.0, 5,125.0kWh로 8월이 가장 큰 냉방열량을 나타내었다.