• 제목/요약/키워드: 냉매R245fa

검색결과 15건 처리시간 0.153초

수평 평활관내 R245fa의 흐름 응축 열전달 특성 (Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube)

  • 박현신;박기정;정동수
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.

R-245fa 및 NOVEC 649 작동유체에 따른 ORC 시스템 성능 변화 (ORC System Performance Analysis upon R-245fa and Novec 649)

  • 장홍순;한영섭;송영길;김성현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.17-23
    • /
    • 2016
  • A test unit for Organic Rankine Cycle (ORC) power generation system was developed and experimentally reviewed the performance of the ORC system. Two different organic fluids (R-245fa & Novec 649) were tested as working fluids for the system. System behavior was measured and analyzed along with the variables, such as temperature, pressure, rpm and shaft power. It is one of the findings that Novec 649 fluid is to be less pressurized than R-245fa in order to up to the heat source (boiler) capacity, that limits the experiment as high as 2 kW in shaft power.

수평관에서 R245fa의 응축 열전달계수 (Condensation Heat Transfer Coefficients of R245fa on a Plain Tube)

  • 심윤보;박기정;정동수;김종성
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

낮은 핀관과 Turbo-C 촉진관에서 R245fa의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R245fa on Low Fin and Turbo-C Tubes)

  • 심윤보;박기정;정동수
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.167-175
    • /
    • 2009
  • In this study, condensation heat transfer coefficients(HTCs) of R22, R123, R134a and R245fa are measured on both 26fpi low fin and Turbo-C tubes. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling of $3{\sim}8^{\circ}C$. Test results show that HTCs of the newly developed low vapor pressure alternative refrigerant, R245fa, are $7.8{\sim}9.2%$ and $10.3{\sim}18.6%$ higher than those of R123 for 26fpi low fin tube and Turbo-C tube respectively. For all refrigerants tested, HTCs of Turbo-C enhanced tube are higher than those of 26fpi low fin tube. For the low fin tube, Beatty and Katz's prediction equation yielded 20% deviation for all fluids. The heat transfer enhancement ratio of R245fa on the Turbo-C tube is $5.9{\sim}6.4$ while that of R123 is $5.7{\sim}5.9$. From the view point of environmental safety and condensation heat transfer, R245fa is a long term candidate to replace R123 currently used in centrifugal chillers.

평활관과 낮은 핀관에서 R245fa의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficient of R245fa on the Plain Tube and the Low Fin Tube)

  • 박기정;이요한;임병덕;정동수
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.208-215
    • /
    • 2011
  • In this work, pool boiling heat transfer coefficients(HTCs) of R22, R123, R134a, and R245fa are measured on both horizontal plain and 26 fpi low fin tubes. The pool boiling temperature is maintained at $7^{\circ}C$ and heat flux is varied from 80 $kW/m^2$ to 10 $kW/m^2$ with an interval of 10 $kW/m^2$. Wall temperatures are measured directly by thermocouples inserted through holes of 0.5 mm diameter. Test results show that HTCs of high vapor pressure refrigerants are usually higher than those of low pressure fluids in both plain and low fin tubes. On a plain tube, HTCs of R245fa are 23.3% higher than those of R123 while on a 26 fpi low fin tube, HTCs of R245fa are 46.3% higher than those of R123. The fin effect is more prominent with low vapor pressure refrigerants than with high vapor pressure ones due to a sweeping effect.

냉매(R245fa)를 이용한 유기랭킨 사이클에 관한 연구 (A Study on the Organic Rankine Cycle Using R245fa)

  • 조수용;조종현;김진환
    • 한국유체기계학회 논문집
    • /
    • 제16권3호
    • /
    • pp.10-17
    • /
    • 2013
  • The organic Rankine cycle has been widely used to convert the renewable energy such as the solar energy, the geothermal energy, or the waste energy etc., to the electric power. Some previous studies focused to find what kind of refrigerant would be a best working fluid for the organic Rankine cycle. In this study, R245fa was chosen to the working fluid, and the cycle analysis was conducted for the output power of 30kW or less. In addition, properties (temperature, pressure, entropy, and enthalpy etc.) of the working fluid on the cycle were predicted when the turbine output power was controlled by adjusting the mass flowrate. The configuration of the turbine was a radial-type and the supersonic nozzles were applied as the stator. So, the turbine was operated in partial admission. The turbine efficiency and the optimum velocity ratio were considered in the cycle analysis for the low partial admission rate. The computed results show that the system efficiency is affected by the partial admission rate more than the temperature of the evaporator.

ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석 (Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus®)

  • 임석연;김형근;유상석
    • 대한기계학회논문집B
    • /
    • 제39권4호
    • /
    • pp.317-324
    • /
    • 2015
  • 본 연구에서는 아파트단지에 적용되는 태양열 급탕 시스템의 에너지 활용도를 높이기 위해 유기랭킨사이클을 적용하여 해석적 연구를 수행하였다. 시스템 해석은 Aspen $Plus^{(R)}$을 활용하였으며 태양열집열기는 급탕 온도와 유기랭킨 사이클의 운전 조건을 고려하여 진공관형 집열기를 적용하였다. R134a, R141a, R245fa 등의 냉매를 작동유체로 선정하였으며, 시스템 성능해석을 통하여 R245fa 냉매가 적용가능성이 가장 높게 나타났다. 비가역성 해석과 민감도 해석을 통해 유기랭킨 사이클 시스템의 효율 및 성능 확보를 위해서는 증발기와 터빈에 대한 기술 개발이 매우 중요하다는 것을 밝혀냈으며, 순수 급탕으로만 활용하는 시스템에 전기 생산 설비를 추가하게 되면 약 50%의 추가적인 경제성이 확보됨을 확인하였다.

두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향 (Performance Analysis of an ORC System for Two Different Working Fluids)

  • 장홍순;송영길;한영섭
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.413-417
    • /
    • 2013
  • The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

R245fa 냉매를 이용한 배열회수 히트펌프 시스템 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Recovery Heat Pump System using R245fa Refrigerant)

  • 김현택;김용찬;차동안;권오경
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.408-413
    • /
    • 2016
  • The objective of this study is to investigate the performance of a heat recovery heat pump dryer using a R245fa refrigerant experimentally. In this study, the main components of the heat pump dryer were an evaporator, a compressor, a condenser, and an expansion valve. As a result, when the amount of refrigerant varied from 15 kg to 16 kg, the hot air outlet temperature in the condenser and the heat transfer rate were almost kept constant. Therefore, the amount of refrigerant at 16 kg was considered to be a suitable amount in the heat pump. As the air inlet velocity varied from 0.5 m/s to 1.5 m/s, the highest temperature in the condenser could be obtained when the air inlet velocity was 0.5 m/s. The heat transfer rate, system (COP), and hot air outlet temperature were 5.6 kW, 3.4, and $102.5^{\circ}C$, respectively, when the bypass ratio and water temperature were 0% and $60^{\circ}C$.

배기가스 배열을 활용한 R245fa 냉매용 고온 히트펌프 건조기의 해석 및 검증 (Analysis and Verification of High Temperature Heat Pump Dryer using Waste Heat Recovery Type for R245fa Refrigerant)

  • 배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.73-78
    • /
    • 2016
  • In this study, the performance characteristics of a high temperature heat pump dryer that is able to raise the air temperature up to $80^{\circ}C$ by using waste heat as heat source were investigated numerically. The main components of the heat pump dryer were modeling as a compressor, condenser, evaporator and expansion device, and R245fa was selected as refrigerant. Experiments were also conducted to validate the numerical data. As a result, when the evaporator air inlet temperature increased from $50^{\circ}C$ to $65^{\circ}C$, the numerical results of the hot air temperature at outlet and heat pump COP were about 8~11% and 5~8% higher than that of experimental ones, respectively.