• 제목/요약/키워드: 냉매502

검색결과 13건 처리시간 0.028초

저온용 R502 대체 냉매의 이론 및 실험적 평가 (Theoretical and Experimental Evaluation of R502 Alternatives in Low Temperature Applications)

  • 권승림;박윤범;정동수;김종보;강득주
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.654-666
    • /
    • 1995
  • R502 has been extensively used as a working fluid in transport refrigerating vehicles and low temperature refrigerating machines but is to be phased out by the end of 1995 due to ozone layer depletion problem. In this study, both theoretical cycle analysis and experiments were carried out to examine the best substitutes for R502. Theoretical results indicate that the alternatives available in the market today may replace R502 without significant changes in the system without suction line heat exchanger(SLHX). When the system contains a SLHX, however, COPs of the alternatives increase up to approximately 15~20% than those without the SLHX. But simultaneously, the discharge temperatures of the compressor also increrease significantly with the SLHX. Actual test results obtained from the experiment with a transport vehicle's refrigerator indicate the similar trend as those of the theoretical results. Especially, HFCs and their mixtures show lower discharge temperature than those of R502, which is one of the desirable features. Further research is needed to study the effect of the SLHX on the performance of the real machine as well as on the oil return for reliability of the system.

  • PDF

R-502 대체 혼합냉매의 성능에 관한 실험적 연구 (Experimental study on the performance of R-502 alternative refrigerant mixtures)

  • 박동민;정동수;김종보;강득주
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.198-209
    • /
    • 1997
  • This paper is concerned about the performance of alternative refrigerants of R-502 which has been widely used in transport and low temperature refrigeration. A breadboard heat pump was constructed with counterflow heat exchangers and tested with R-502 and transitional alternatives of R-402A and R-402B and long-term alternatives of R-404A and R-507 to compare the performance of each refrigerant. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$ and $52.0^{\circ}C$ and the evaporating temperature was varied over a range from $-25^{\circ}C$ to $-5^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about $5^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this research work can be used as 'drop-in' fluids to replace R-502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

저온용 R502 대체냉매의 성능 평가 (Performance of R502 Alternative Refrigerants for Low Temperature Applications)

  • 하종철;황지환;백인철;정동수
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.883-890
    • /
    • 2005
  • In this study, 2 pure hydrocarbon refrigerants of R1270 (Propylene) and R290 (Propane) and 3 binary mixtures composed of R1270, R29O and R152a were tested in a refrigerating bench tester with a scroll compressor in an attempt to substitute R502 used in most of the low temperature applications. The test bench provided 3\sim3.5$ kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of -28 and $45^{\circ}C$ in the evaporator and condenser, respectively. Test results showed that all refrigerants tested had $9.6\sim18.7\%$ higher capacity and $17.1\sim27.3\%$ higher COP than R502. The compressor discharge temperature of R1270 was similar to that of R502 while those of all other refrigerants were $23.7\sim27.9\%$ lower than that of R502. For all alternative refrigerants, the amount of charge was reduced up to $60\%$ as compared to R502. Overall, these alternative refrigerants offer better system performance and reliability than R502 and can be used as long term substitutes for R502 due to their excellent environmental properties.

저온용 대체냉매의 성능 특성 연구 (Performance Characteristics Study on an Alternative Refrigerant in Low Temperature Applications)

  • 신정섭;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.462-469
    • /
    • 2016
  • This paper presents the results of thermodynamic cycle analysis and performance tests of alternative mixtures in low temperature applications. Two near-azeotropic binary mixtures R-152a/R-1270 (35:65 by wt.%) and R-290/E170 (35:65 by wt.%) are considered in this study. They have zero ODP (Ozone Depletion Potential) and much lower GWP (Global Warming Potential) than R-404A which is an alternative of R-502. Refrigeration cycle characteristics such as cooling capacity, coefficient of performance, suction and discharge pressures and temperatures are compared to those for the baseline refrigerants (R-502 and R-404A) cycles. The performance tests are conducted at the evaporation and condensation temperatures of $5^{\circ}C$ and $45^{\circ}C$, subcooling and superheating temperatures of $5^{\circ}C$, respectively. Performance comparisons between baseline and alternative refrigerants are conducted on the same cooling capacity. The system performance of newly proposed refrigerant mixtures show promising results.

R-502의 대체냉매를 사용한 냉동시스템의 성능 및 열전달 특성 (Performance and heat transfer characteristics of refrigeration system using R-502 alternatives)

  • 박창대;김민수;노승탁
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.624-632
    • /
    • 1999
  • In order to replace CFC-502 which has been widely used in transportation and low temperature refrigeration system, performance tests using HFC-407A, HFC-404A and HFC-507 have been carried out. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$and $54.5^{\circ}C$ for each refrigerant. System performance characteristics and heat transfer characteristics of each refrigerant were obtained at several compressor speeds and evaporating temperatures ranging from$-25^{\circ}C$ to $-10^{\circ}C$ Test results show that the use of tested alternative refrigerants without changing system components offers the potential performance improvement of a refrigeration system.

  • PDF

수평증발관내 R22/R114 혼합냉매의 열전달 특성에 관한 연구 (A Study for Evaporation Heat Transfer Characteristic of R22/Rl14 Refrigerant Mixtures in a Horizontal Tube)

  • 윤치한;이종인;하옥남
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.502-510
    • /
    • 2000
  • Evaporation heat transfer characteristics were studied in a horizontal tube using R22/R114 non-azotropic refrigerant mixture. the heat transfer coefficient was high in the upper part for pure refrigerants, and heat transfer coefficient was low in the lower part for refrigerant mixtures. In the low quality region where nucleate boiling was dominant, the average heat transfer coefficient was low. In the region where forced convection was dominant, heat transfer coefficient was high. Results show that the heat transfer coefficient for pure refrigerants obtained by experiments were lower than those of Yoshida et al. but agreed well with Jung et al., and Chen et al. data. But the heat transfer coefficients for refrigerant mixtures were lower about 20% than those predicted by the equation for pure refrigerant.

  • PDF

대체냉매의 2중관 응축기 열 및 물질전달과 성능평가 (Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant)

  • 이상무;박병덕;소산번
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

혼합냉매(R-290/R-32)를 사용하는 소프트 아이스크림 제조기의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of the Soft Ice Cream Machine Run by Refrigerant Mixture (R-290/R-32))

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.719-725
    • /
    • 2017
  • 최근 들어 국민 식생활 문화가 개선되고 생활수준이 향상됨에 따라 소프트 아이스크림, 슬러시와 같은 일회용 냉동 유제품의 소비가 급증하고 있다. 이들 냉동 유제품은 소형 냉동 시스템에서 만들어진다. 소프트 아이스크림 제조기의 냉매로 그간 R-502가 주로 사용되어 왔으나 오존층 파괴와 관련하여 R-404A로 대체되고 있다. 하지만 R-404A도 지구온난화지수(GWP)가 높아 지구온난화지수가 낮은 냉매로의 전환이 필요하다. 본 연구에서는 R-404A의 대체 물질로 R-290/R-32를 고려하였다. 냉각기 체적 2.8 리터인 소프트 아이스크림 제조기에 R-290/R-32를 적용하여 최적화를 수행하였다. 최적화는 적정 냉매량 및 팽창밸브의 개도를 찾는데 주안점을 맞춰 수행되었는데 최적 조건 (충전량 1000 g, 밸브 개도 "0" (제조사 세팅치))에서 아이스크림 제조 시간은 6분 24초, COP는 0.83으로 나타났다. R-404A에서 아이스크림 제조시간은 6분 22초와 R-290/R-32와 유사하고 COP는 0.90으로 R-404A에서 다소 높게 나타났다. 이는 본 실험에 사용된 압축기가 R-404A용이기 때문으로 향후 R-290/R-32용 압축기가 개발되면 소비동력은 개선되리라 예상된다. 본 연구 결과는 냉동식품 제조기를 비롯한 여타 냉동 사이클의 최적화에도 활용될 수 있을 것이다.

R-404A를 사용하는 소프트 아이스크림 제조기의 냉매 충전량 및 팽창 밸브 개도 최적화 (Optimization of the Refrigerant Charge and the Expansion Valve Opening for the Soft Ice Cream Machine Using R-404A)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.728-734
    • /
    • 2016
  • 최근 들어 국민 식생활 문화가 개선되고 생활수준이 향상됨에 따라 소프트 아이스크림, 슬러시와 같은 일회용 냉동 유제품의 소비가 급증하고 있다. 이들 냉동 유제품은 소형 냉동 시스템에서 만들어진다. 소프트 아이스크림 제조기의 냉매로 그간 R-502가 주로 사용되어 왔으나 오존층 파괴와 관련하여 R-404A로 대체되고 있다. 본 연구에서는 냉각기 체적 2.8 리터인 R-404A를 사용하는 소프트 아이스크림 제조기에 대하여 최적화와 성능평가를 수행하였다. 최적화는 적정 냉매량 및 팽창 밸브의 개도를 찾는데 주안점을 맞춰 수행되었다. 최적 조건에서 아이스크림 제조 시간은 10분 5초, COP는 0.57로 나타났다. 이 제품에 대하여 무 간격 연속 판매 시험, 30초 간격 연속 판매 시험, 극한 시험을 수행하여 성능을 평가하였다. 무 간격 연속 판매는 20개까지 가능하였고 30초 간격 연속 판매는 무한대로 가능하였다. 또한 여름철 및 겨울철 환경에도 아이스크림 판매가 가능한 것으로 나타났다. 본 연구 결과는 냉동식품 제조기를 비롯한 여타 냉동 사이클의 최적화에도 활용될 수 있을 것이다.

12가지 냉매 (R11, R12, R13, R14, R21, R22, R23, R113, R114, R500, R502, C318)의 상태치계산 프로그램 (Development of Computer Program for Computation of 12 Refrigerant Properties)

  • 이기방;정명균
    • 대한설비공학회지:설비저널
    • /
    • 제16권5호
    • /
    • pp.477-483
    • /
    • 1987
  • A FORTRAN code has been developed to calculate thermodynamic properties of 12 kinds of refrigerants. Input variables are temperature and pressure or temperature only depending on the saturation. The program output properties are specific volume, saturation pressure, enthalpy, entropy, specific heats and speed of sound. Sample calculations show that output properties are in very good agreements with thermodynamic tables and charts.

  • PDF