• Title/Summary/Keyword: 냉매 22

Search Result 235, Processing Time 0.021 seconds

Flux Analysis of Air-conditioner Coupling (에어컨디셔너의 냉매배관을 연결하는 커플링의 유동해석)

  • Lee, Su-Yul;Kim, Woo-Seung;Cho, Soo;Sung, Uk-Joo;Park, Hee-Mun;Sim, Kyung-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1031-1036
    • /
    • 2009
  • This study is intended to identify how quick disconnect coupling which connects with refrigerant piping of air-conditioner using R-22 refrigerant has effect on characteristics of flux. in the case where the air-conditioner installs utilizes quick disconnect coupling, COP has an effect on the quantity of cooling load because of changing flow rate and physical properties of refrigerant which flow into an entrance of expansion valve from coupling. Variation of flow rate can be regulated by changing expansion-contraction angle; $\alpha$ of an entrance and an exit of coupling. In this study, quick disconnect coupling is presented flow of coupling by using FLUENT as heat flow program. To have an effect on the expansion entrance valve, and by changing expansion-contraction angle; $\alpha$ of an entrance and an exit

  • PDF

Soft ice-cream maker operating with mixed refrigerant R290/R32 (혼합냉매 (R290/R32) 적용 소프트 아이스크림 제조기 (drop-in 시험))

  • Park, Tae-Gyun;Han, Seong-Pil;Lee, Eung-Ryeol;Kim, Nae-Hyeon;Park, Hyeong-Chae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.410-413
    • /
    • 2005
  • Drop-in tests were conducted using R290/R32 (31:69) mixture in an ice-cream maker for possible replacement of R-502 and R-404A. Optimum refrigerant charge and TEV opening were obtained through a series of experiments. At the standard outdoor condition ($35^{\circ}C$ DT, $24^{\circ}C$ WT), the time required for initial ice-cream making was 6'22", which was approximately the same as that of R-404A. The electric energy consumed was 660 kJ, which was about 10% higher than that of R-404A. The compressor outlet temperature ($8^{\circ}C$) and pressure (2.52 MPa) were higher than those ($60^{\circ}C$ and 1.48 MPa) of R-404A. The reason could be the usage of the same R-404A compressor although the specific volume of R290/R32 is much larger.

  • PDF

Performance characteristics of a multi type refrigerator (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Jang, Ui-Young;Park, Yong-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

Suggestion of Test Apparatus for Reliability Evaluation of a Rotary Compressor with a Short-Cycle (로터리 압축기용 Short-Cycle 신뢰성 시험장치 제안)

  • Lee, Tae-Gu;Lee, Sang-Jae;Kim, Hyun-Woo;Kim, Sang-Hyun;Lee, Jae-Heon;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.584-589
    • /
    • 2006
  • In this paper, a test apparatus for reliability evaluation of a rotary compressor has been suggested with a short-cycle concept. $CO_2$ refrigerant is adopted for this cycle to avoid phase change during cycle operation. Evaporator is not necessary in short-cycle. Utilizing a short-cycle, the test apparatus was built on the purpose of evaluating the reliability of each rotary compressor on the conveyer belt of the factory. The primary validation of the test apparatus is discussed by analyzing the experimental heat balance data. Additional validation was performed through the overload continuous operation test where the wear rate of the $CO_2$ short-cycle was found to similar to that of the R22 normal-cycle. The reliability evaluation test apparatus with a short-cycle in present investigation was found simple and efficient in the view of reducing sample numbers, costs, and test time in analyzing the reliability of rotary compressors.

  • PDF

Improvement of the Waste Refrigerator Pre-processing Line in Metropolitan Recycling Center using Simulation (시뮬레이션 기반 수도권 리사이클링 센터 폐냉장고 전처리 공정 개선)

  • Kim, Do Gyun;Kang, Min Koo;Choi, Jin Young;Park, Kiejin;Kong, Man-Sik
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.4
    • /
    • pp.129-138
    • /
    • 2013
  • This paper studies the improvement of a pre-processing line for waste refrigerators in a metropolitan recycling center(MRC). We performed ARENA modeling and simulation by using work analysis and time measurement on the current processing line. Combined this result with some practical experiences from workers, we generated 3 alternatives to improve the current line and evaluated them by using ARENA simulation. The final decision selected consists of changing 2-line process into 1-line and having a separate cell-line for collecting refrigerant. Currently, the result of this study was applied to MRC by improving cycle time, throughput, and space utilization compared to the previous one.

Evaporation heat transfer characteristics inside the U-bend of the smooth and the microfin tube using alternative refrigerant (대체냉매를 사용한 평활관 및 마이크로핀관 곡관부내 증발 열전달 특성)

  • Jo, Geum-Nam;Kim, Byeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1207-1217
    • /
    • 1997
  • The present work experimentally investigated the effects of mass flux, heat flux, inlet quality on the heat transfer performance inside the U-bend of smooth and microfin tube using R-22 and R-407C refrigerants. The parameters were 200 and 400 kg/m$^{2}$ s for mass flux, 6 and 12 kw/m$^{2}$ for heat flux, 0.1 and 0.2 for inlet quality under the pressure of 0.65 MPa. The apparatus consisted of the test section of four straight sections and three U-bends, preheater, condenser, refrigerant pump, mass flow meter etc. The average heat transfer coefficient at the downstream straight section after U-bend was affected by U-bend due to the centrifugal force and mixing of two-phase flow in the U-bend. The average heat transfer coefficient at the U-bend was 4 ~ 33 % higher than that at the straight section. The average heat transfer coefficients were affected in the order of mass flux, heat flux and inlet quality. The average heat transfer coefficients in the microfin tube were lager by 19 ~ 49% and 33 ~ 69% than that in the smooth tube at the straight section and at the U-bend separately. The average heat transfer coefficients for R-407C were larger by 33 ~ 41% and 17 ~ 29% than that for R-22 in the smooth tube and the microfin tube separately.

Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants (다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Heo, Seong-Kwan;Je, Jae-Myun;Jeon, Min-Ju;Son, Chang-Hyo;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

External Condensation Heat Transfer Coefficients of R245fa on Low Fin and Turbo-C Tubes (낮은 핀관과 Turbo-C 촉진관에서 R245fa의 외부 응축 열전달계수)

  • Shim, Yun-Bo;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.167-175
    • /
    • 2009
  • In this study, condensation heat transfer coefficients(HTCs) of R22, R123, R134a and R245fa are measured on both 26fpi low fin and Turbo-C tubes. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling of $3{\sim}8^{\circ}C$. Test results show that HTCs of the newly developed low vapor pressure alternative refrigerant, R245fa, are $7.8{\sim}9.2%$ and $10.3{\sim}18.6%$ higher than those of R123 for 26fpi low fin tube and Turbo-C tube respectively. For all refrigerants tested, HTCs of Turbo-C enhanced tube are higher than those of 26fpi low fin tube. For the low fin tube, Beatty and Katz's prediction equation yielded 20% deviation for all fluids. The heat transfer enhancement ratio of R245fa on the Turbo-C tube is $5.9{\sim}6.4$ while that of R123 is $5.7{\sim}5.9$. From the view point of environmental safety and condensation heat transfer, R245fa is a long term candidate to replace R123 currently used in centrifugal chillers.