• 제목/요약/키워드: 냉매유동

검색결과 94건 처리시간 0.021초

R12 냉매를 이용한 냉동압축기 임펠러 유동해석 (Numerical analysis on the impeller of chiller compressor using refrigerant R12)

  • 음학진;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

R407C 및 R290 냉매에 대한 모세관내 유동특성 실험 및 모델링 (Experimentation and modeling on the flow of R407c and R290 through capillary tubes)

  • 김용찬;조일용;최종민
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.492-498
    • /
    • 1999
  • Mass flow rates of R407C and R290 through capillary tubes were measured with various capillary tube geometries and flow conditions. For all refrigerants tested in the present study, mass flow rate through the capillary tube was strongly dependent on the condensing pressure, subcooling and capillary length and diameter. The flow rate of R407C was 5~10[%] higher than that of R22 at the same condensing temperature and degree of subcooling, while flow rate for R290 was 40[%] lower than that for R22. Based on experimental results, an empirical correlation was developed using Pi theorem to predict the mass flow rate through capillary tubes. The predicted flow rates using the model were consistent with the experimental data within ${\pm}$10[%].

  • PDF

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

증발기 어큐뮤레이터에서의 버블 소음 규명 및 개선 (Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator)

  • 박정희;장의영;박윤서
    • 소음진동
    • /
    • 제6권4호
    • /
    • pp.513-519
    • /
    • 1996
  • This paper is concerned with the bubble sound at the accumulator which is generated by the difference of the high pressure side and the low pressure side in the cycle of the refrigerator. The causes of the bubble sound generation are verified by the visualized test of the operating refrigerant flow at the accumulator and the measurements of the temperature and pressure. Two cases were tested, one with the accumulator has a orifice and the other with the accumulator hasn't a orifice. So that, it is presented the comparison of the bubble sound levels and spectrums in each cases. To predict the bubble sizes when they are generated, the linearized equation driven by Strasberg is used.

  • PDF

A/C 실내기 배관 형상에 따른 냉매 유동 소음 특성에 관한 연구 (The refrigerant flow noise from the A/C distribute pipe line shapes)

  • 배성원;허덕;오세기;정백영;오일권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.371-375
    • /
    • 2009
  • The distribution control of refrigerant flow is one of the basic technique to enhance system efficiency. However, if engineers forget to control the refrigerant flow speed in all operation range, refrigerant flow mal distribution becomes a noise source. The refrigerant flow noise should be checked and controlled at the lowest air flow mode which is the most silent mode and frequently used in night time.

  • PDF

냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가 (Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator)

  • 허소정;김민성;한형석;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권10호
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

혼합냉매의 환상 유동 증발열전달 해석 (Analysis of Convective Boiling Heat Transfer for Refrigerant Mixtures in Annular Horizontal Flow)

  • 신지영;김민수
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.720-729
    • /
    • 1996
  • An analysis of convective boiling heat transfer for refrigerant mixtures is performed for an annular flow to investigate the degradation of the heat transfer rate. Annular flow is selected in this study because a great portion of the evaporator in the refrigeration and air conditioning system is known to be in the annular flow regime. Mass transfer effect due to composition difference between liquid and vapor is included in this analysis, which is considered to be one of driving forces for the mass transfer at the interface. Due to the concentration gradient at the interface the mass transfer is interfered, so is the evaporative heat transfer at the interface. The mass transfer resistance makes the interface temperature slightly higher and, as a result, the heat transfer coefficients decrease compared with those without mass transfer effects. The degradatioin of the heat transfer rate reaches its maximum at a certain composition. The composition difference between vapor core and vapor at the interface has a direct effect on the temperature difference between the vapor core and the interface and the degradation of the heat transfer rate. Correction factor $C_{F}$ for the mixture effects is added to the correlation for pure substances and the flow boiling heat transfer coefficients can be calculated using the modified equation.n.

세관내 R-134a의 유동특성에 관한 실험적 연구 (An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1307-1312
    • /
    • 2007
  • 본 논문은 세관내 R-134a의 유동특성을 실험적으로 조사한 것이다. 이에 대한 실험장치는 마그네틱 기어 펌프, 증발기, 수액기, 사이트 글라스, 응축기 계측기로 구성된다. 유동양식을 관찰하기 위한 사이트 글라스는 증발기 입출구에 설치하였다. 실험은 세관내 R-22와 R-134a의 유동특성을 살펴보기 위해서 수행되었다. 이에 대한 실험변수인 냉매질량 유속은 100에서 1000 $kg/m^2s$이고, 포화온도는 $30^{\circ}C$이다. 증발과정 중의 유동양식에서 2 mm의 세관내 환상유동은 8 mm관의 대구경관에 비해 저건도와 저질량유속에서 발생하였다. 본 실헐 결과와 종래의 유동양식 선도와 비교한 결과, 2 mm의 세관내 증발 유동양식은 Baker, Mandhane, Taitel-Dukler의 유동양식 선도와는 큰 차이를 보였지만, Dobson의 유동양식 선도와는 좋은 일치를 보였다.

  • PDF

수평평활 세관 내에서의 R-290, R-600a, R-22의 응축열전달과 압력강하 특성 (Condensation Heat Transfer Characteristics and Pressure Drop of R-290, R-600a, and R-22 in Horizontal Smooth Pipes with a Small Diameter)

  • 노건상;손창효
    • 청정기술
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2008
  • 본 연구에서는 내경이 각각 5.80 mm와 10.07 mm인 두 개의 수평 이중관열교환기 내에서의 탄화수소계 냉매의 응축열전달과 압력강하에 대한 실험을 $35.5{\sim}210.4\;kg/m^2\;s$의 질량유속과 응축온도인 $40^{\circ}C$에서 수행하였다. 탄화수소계 냉매 R-290과 R-600a의 응축열전달계수가 프레온계 냉매인 R-22보다 높았다. 응축압력강하는 R-600a > R-290 > R-22 순으로 나타났고, 내경이 5.8 mm인 관 내 보다 10.07 mm인 관 내의 압력강하가 R-600a에서는 $6{\sim}15%$ 정도 높았으며, R-290과 R-22에서는 각각 $9.8{\sim}12.5%$$2.1{\sim}4.6%$ 정도 높게 나타났다. 실험으로 구한 응축열전달계수와 종래의 상관관계식을 비교해 본 결과, 모든 관경에 대해 Haraguchi 등의 상관관계식과 가장 좋은 일치를 보였다.

  • PDF

전산유체역학을 이용한 화장품 오일 캡슐레이션 현상에 대한 연구 (A Study on the Encapsulation of Cosmetic Oil Using Computational Fluid Dynamics)

  • 정남균
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.638-643
    • /
    • 2021
  • 농업분야를 비롯한 식품산업 등 다양한 산업에서 사용되고 있는 오일은 기능성 화장품 개발에도 주요한 원료로 사용되고 있다. 오일은 산소나 빛, 습기 또는 고온에 노출되면 화학적으로 불안정하고 산화되기가 쉬운 특징이 있어 이러한 환경에 그대로 노출되지 않도록 캡슐화하기 위한 다양한 시도가 이루어지고 있다. 오일보다 밀도가 큰 냉매 안에 오일을 주입하면, 오일과 냉매의 밀도차로 인한 부력에 의해 오일이 떠오르면서 오일을 캡슐화 할 수 있는데, 본 연구에서는 이러한 방식의 오일 캡슐레이션 장비를 개발함에 있어 오일 캡슐화의 최적의 장비 구동조건을 찾기 위하여 다상유동에 대한 전산해석을 이용하여 오일 캡슐레이션 현상을 모사하였다. 냉매로는 물이나 세럼(Serum)을 이용할 수 있는 데, 상대적으로 점도가 상당히 작은 물을 냉매로 사용했을 경우는 오일과 물을 지속적으로 주입시키는 방식으로 장비를 구동하더라도 오일액적이 잘 생성됨을 알 수 있었으나, 점도가 매우 큰 세럼을 냉매로 사용했을 경우는 오일이 액적의 형태로 노즐에서 이탈되지 않고 길게 늘어지는 양상을 나타냈다. 세럼을 냉매로 이용한 경우는 오일을 연속으로 주입시키는 방법 대신 짧은 순간 빠르게 주입한 후 얼마의 시간동안 주입을 멈춰 부력에 의해 오일액적을 노즐로부터 이탈시키는 방법을 이용하면 오일액적 생성이 가능함을 알 수 있었다.