Study on Performance Improvement Air Cooled Condenser Considering Ambient Condition (대기 조건에 따른 공랭식 응축기 성능 저하 개선 연구)

  • Cha, Hun;Ryu, Gwang-Nyeon;Kim, Jung-Rae
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • Air cooled condenser for power plant is used at inland area of desert or mountainous area because condenser coolant like sea water is not necessary. However, the performance of air cooled condenser is influenced by ambient condition such as wind speed and air temperature. Therefore, various devices have been designed to improve the performance of air cooled condenser. In this study, the CFD analysis for air cooled condenser was carried out according to wind speed and wind screen configuration. As wind speed increased from 3m/s to 7m/s, the fan flow rate was reduced about 15.76% and the rise of inlet air temperature was 5.55 degree of Celsius. When the suitable wind screen is equipped, the fan flow rate went up about 5.18% and inlet air temperature dropped by 2.08 degree of Celsius in comparison with original case without wind screen at 7m/s wind speed.

An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube (세관내 R-134a의 유동특성에 관한 실험적 연구)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1307-1312
    • /
    • 2007
  • The flow characteristics of R-134a in a small diameter tube was investigated experimentally. An experimental apparatus was consisted of a magnetic gear pump, an evaporator, a sight-glass, a condenser and a measurement instruments. The sight-glass for flow pattern observations was located at the inlet and outlet of the evaporator. The experiment was carried out to show the flow characteristics of R-134a in a small diameter tube. Mass flux of refrigerants was ranged from 100 to 1000 $kg/m^2s$, the saturation temperature was $30^{\circ}C$. In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to that in a 8 mm inner diameter tube. The evaporation flow pattern in a small diameter tube has been shown major deviations with the Baker, Mandhane and Taitel-Dutler's flow pattern maps but it was similar to the Dobson's flow pattern map.

  • PDF

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles (전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법)

  • Kim, Dae-Wan;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2545-2552
    • /
    • 2014
  • This study is aiming to suggest the effective thermal management system design technologies for the high voltage and capacity battery system of the electricity driven vehicles and introduce the theoretical designing methods. In order to investigate the effective operation of the battery system for the electricity driven vehicles, the heat generation model for Li-ion battery system using the chemical reaction while charging and discharging was suggested and the thermal loads of the heat sources (air or liquid) for cooling and heating were calculated using energy balance. Especially, the design methods for the cooling and heating of the battery system for maintaining the optimum operation temperature were investigated under heating, cooling and generated heat (during charging and discharging) conditions. The battery thermal management system for the effective battery operation of the electricity driven vehicles was suggested reasonably depending on the variation of the season and operation conditions. In addition, at the same conditions under summer season, the cooling method using the liquid and active cooling technique showed a relatively high capacity, while cooling method using the passive cooling technique showed a relatively low capacity.

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

A study on the 3-step classification algorithm for the diagnosis and classification of refrigeration system failures and their types (냉동시스템 고장 진단 및 고장유형 분석을 위한 3단계 분류 알고리즘에 관한 연구)

  • Lee, Kangbae;Park, Sungho;Lee, Hui-Won;Lee, Seung-Jae;Lee, Seung-hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.31-37
    • /
    • 2021
  • As the size of buildings increases due to urbanization due to the development of industry, the need to purify the air and maintain a comfortable indoor environment is also increasing. With the development of monitoring technology for refrigeration systems, it has become possible to manage the amount of electricity consumed in buildings. In particular, refrigeration systems account for about 40% of power consumption in commercial buildings. Therefore, in order to develop the refrigeration system failure diagnosis algorithm in this study, the purpose of this study was to understand the structure of the refrigeration system, collect and analyze data generated during the operation of the refrigeration system, and quickly detect and classify failure situations with various types and severity . In particular, in order to improve the classification accuracy of failure types that are difficult to classify, a three-step diagnosis and classification algorithm was developed and proposed. A model based on SVM and LGBM was presented as a classification model suitable for each stage after a number of experiments and hyper-parameter optimization process. In this study, the characteristics affecting failure were preserved as much as possible, and all failure types, including refrigerant-related failures, which had been difficult in previous studies, were derived with excellent results.

Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers (나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구)

  • Lee, Sang Hun;Yoon, Won Jae;Kim, Yongchan;Lee, Mooyeon;Yun, Seongjung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.205-212
    • /
    • 2013
  • The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

Case Studies for SMR Natural Gas Liquefaction Plant by Capacity in Small Scale Gas Wells through Cost Analysis (소규모 가스전 규모에 따른 SMR 천연가스 액화 플랜트 용량별 비용 분석 사례연구)

  • Lee, Inkyu;Cho, Seungsik;Lee, Seungjun;Moon, Il
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.46-51
    • /
    • 2016
  • Natural gas liquefaction process which spends a huge amount energy is operated under cryogenic conditions. Thus, many researchers have studied on minimizing energy consumption of LNG plant. However, a few studied for cost optimization have performed. This study focused on the cost analysis for the single mixed refrigerant (SMR) process, one of the simplest natural gas liquefaction process, which has different capacity. The process capacity is increased from 1 million ton per annum (MTPA) to 2.5 MTPA by 0.5 MTPA steps. According to the increase of plant size, only flow rate of natural gas and mixed refrigerant are increased and other operating conditions are fixed. Aspen Economic Evaluator(v.8.7) is used for the cost analysis and six tenths factor rule is applied to obtain multi stream heat exchanger cost data which is not supplied by Aspen Economic Evaluator. Moreover, the optimal plant sizes for different sizes of gas wells are found as the result of applying plant cost to small scale gas wells, 20 million ton (MT), 40 MT, and 80 MT. Through this cost analysis, the foundation is built to optimize LNG plant in terms of the cost.

An analytical study on the thermal performance of multi-tube CO2 water heater (다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구)

  • Chang, Keun Sun;Choi, Youn Sung;Kim, Young-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.23-30
    • /
    • 2016
  • In this study, the heat transfer and pressure drop characteristics were evaluated for multi-tube $CO_2$ water heaters with lengths of 4.5 m and 7.5 m. The evaluation was done using the -NTU method, and the results were compared with experimental data. Water flows through the shell side of the water heater, while $CO_2$ flows through 8 inner tubes. The heater uses a counter-current design to maximize the heat transfer efficiency. The energy balance equation describing the flows of $CO_2$ and water for each node is set up using the section-by-section method. The calculated heat transfer rates agree well with the experimental data within ${\pm}5%$ error. The outlet water temperature decreased linearly with the increase of the water flow rate. The calculated heat transfer rates agreed well with the experimental data within ${\pm}3%$ error. The results show that the heat transfer rate increases almost linearly with the increase of water flow rate or $CO_2$ inlet temperature in both the 4.5-m and 7.5-m water heaters, whereas the water outlet temperature linearly decreases with the increase of the water flow rate. The comparison of the $CO_2$ pressure drop between the calculation and experiment results shows good agreement at the high $CO_2$ flow rate within 5 % error, but the value is about 20 % higher in the experimental pressure drop at the low $CO_2$ flow rate.

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.