Performance comparison of cascade refrigerator and two-stage compression refrigerator (캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.625-631
    • /
    • 2014
  • In order to obtain a low evaporation temperature ranging from $-30^{\circ}C{\sim}-50^{\circ}C$, a cascade refrigeration system and two-stage compression one-stage expansion refrigeration system is required. However, the research results of performance comparison of these refrigeration system are very scarce. This paper were compared the performance characteristics of R744-R404A cascade refrigeration system and R404A two-stage compression refrigeration system. The COP of R404A two-stage compression refrigeration system is about 36~57% greater than that of R744-R404A cascade refrigeration system in the range of evaporation temperature of $-30^{\circ}C{\sim}-50^{\circ}C$. But R404A two-stage compression refrigeration system is unstable because COP is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. In this case, not efficient for long-term use. Whereas R744-R404A cascade refrigeration system using natural refrigerants. Therefore, it is environmentally friendly. And this system is high-efficiency refrigeration system. The reason it can be configured by selecting the suitable refrigerant at high-temperature side and low-temperature side. From the above results, select the appropriate low temperature refrigeration system by considering the environmental and performance aspects.

Design of Capillary Tube for a Refrigeration Systems (냉동시스템의 모세관 설계)

  • 정백영;함성훈;김태진
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.966-972
    • /
    • 1993
  • 모세관(capillary tube)은 일정면적식 팽창기구의 대표적인 것으로서 사용역사가 길고, 신뢰성이 높고, 가격이 저럼하므로 냉동공조시스템의 냉매제어장치로 매우 많이 사용되고 있다. 이것은 냉동시스템의 응축기와 증발기 사이에서 유입하는 고압의 액상냉매를 증발기에서 증발하기 쉬운 증발압력까지 압력을 강하시키는 감압팽창작용과 증발기의 증발 용량에 적당한 냉매 질량유량을 공급하는 역할 (이 작용은 냉동시스템의 용량과 작동범위를 결정하는데 매우 중요하다.)을 한다. 이 글에서는 모세관의 형상, 재질 및 그장 . 단점과 작동원리, 내부 유동현상 등 일반적인 사항에 관하여 기술한다.

  • PDF

건물공조용 CHP시스템의 흡착식 냉동기 적용

  • 박윤철
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.28-32
    • /
    • 2005
  • 최근에 보급이 활성화되고 있는 CHP시스템을 건물공조용으로 이용할 경우에 필수적인 증기압축식 냉동기를 대체할 열구동 냉동기로써 흡착식 냉동기 기술을 언급하였다

  • PDF

태양열 시스템의 선박냉동공조분야 적용 방안

  • Seo, Jeong-Se
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.8
    • /
    • pp.32-47
    • /
    • 2010
  • 태양열구동 냉동시스템을 소개하고, 선박냉동공조분야에 적용할 수 있는 방안에 대해 알아보고자 한다.

  • PDF

이젝터 냉동 시스템

  • 이원희
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.34 no.2
    • /
    • pp.23-27
    • /
    • 2005
  • 기존 증기압축식 냉동시스템에 이젝터를 장착하여 시스템 효율을 향상시키는 여러 가지 방안과 상용화된 Denso 이젝터 시스템에 대해 소개하고자 한다.

  • PDF

AHP를 활용한 국내 냉동물류센터 입지경쟁력 결정요인에 관한 연구

  • 박상형;차준헌;김시현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.05a
    • /
    • pp.68-70
    • /
    • 2023
  • COVI-19 이후 콜드체인 시스템의 중요성이 증가함과 함께 냉동물류센터에 대한 중요성도 부각되고 있다. 향후 냉동물류센터의 양적·질적 팽창은 불가피하며 그에 따른 위치선정의 중요성도 커지고 있다. 하지만, 대다수의 국내 냉동물류센터는 단순보관의 역할 위주에, 도심이나 주요도로와 멀리 떨어져 있고, 노후화의 문제를 가지고 있다. 또한 냉동물류센터는 에너지 소비가 많은 만큼 위치선정에 따른 비용문제도 큰 영향을 미친다. 따라서 본 연구는 AHP를 활용하여 부산 경남 냉동 물류 센터의 위치 경쟁력 결정 요인을 분석하고자 한다. 시설요인, 서비스 요인, 위치 요인, 그리고 비용 요인의 네 가지 영역과 이를 세부적으로 나누어 19개의 항목을 계층화하여 상대적 중요도를 평가하였다. 연구결과는 냉동물류센터의 입지결정요인과 기존에 냉동물류센터에 요구되던 기본적인 요소에 입지경쟁력 분석을 위한 우선 순위를 계층화하였다. 비용요인이 국내 냉동물류센터 입지경쟁력의 결정요인 중 가장 높은 비중을 차지하였다. 실제 시설인프라와 물류연결성은 관련 업종 근무자들이 가장 민감하게 받아들이는 사항이기도 하며 새로운 냉동물류센터의 도입 시에도 필수적으로 참고가 되어야할 것으로 보인다. 본 연구는 냉동물류센터 종사자 및 관련업계 종사자들이 어떠한 요인을 냉동물류센터의 입지경쟁력 결정요인으로 비중 있게 고려하고 있는지를 도출하였고, 향후 입지경쟁력 향상을 위한 전략적 시사점을 제공한다.

  • PDF

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

Performance Characteristics of Cascade Refrigeration System Using R744 and R410A (R744-R410A용 이원 냉동시스템 성능 특성)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1548-1554
    • /
    • 2013
  • This paper presents the analysis on performance characteristics of R744-R410A cascade refrigeration system to offer the basic design data for the operating parameters of this system. The performance of cascade refrigeration system is analyzed by using EES program. The operating parameters include compressor efficiency, and condensing and evaporating temperature in R410A high- and R744 low-temperature cycle, respectively. The COP of this system increases with the decrease of condensing temperature, and increases with the increasing evaporating temperature. And the COP of this system increases with the compression efficiency. Therefore, it can be seen that the compression efficiency, and evaporating and condensing temperature of R744-R410A cascade refrigeration system have an effect on the COP of this system. Also, it can be known that the cascade evaporation temperature with the highest efficiency in each parameter is present. Thus, it is an important to design R744-R410A cascade refrigeration system by considering these parameters.

Exergy Analysis of R744-R404A Cascade Refrigeration System (R744-R404A용 캐스케이드 냉동시스템의 엑서지 분석)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1001-1008
    • /
    • 2011
  • This paper describes an analysis on performance and exergy of R744-R404A cascade refrigeration system with internal heat exchanger to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R744 low- and R404A high- temperature cycle, respectively. The main results are summarized as follows : As the evaporation temperature of cascade heat exchanger increases, the COP of R404A high-temperature cycle increases. But the COP of R744 low-temperature cycle decreases, and the COP of total cascade cycle is almost constant. As cascade evaporation temperature increase, the exergy loss in the R404A condenser and the R744 internal heat exchanger is the largest and the lowest among all components, respectively. Therefore, the exergy loss in the condenser and compressor of R404A must be decreased to enhance the COP of R744-R404A cascade refrigeration system.