• Title/Summary/Keyword: 냉동성적계수

Search Result 35, Processing Time 0.021 seconds

A Study on the Certified Ground Source Heat Pump and Performance Analysis (지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구)

  • Chang Woo Yang;Hee Jeong Kang;Jong Min Choi
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.

Comparison of TIA with ELISA for circulating antibody detection in clonorchiasis (간흡충증에 있어서 항체검출을 위한 Enzyme-linked Immunosorbent Assay와 Thin Layer Immunoassay의 비교)

  • 이용기;유재숙이근태정경일
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.265-269
    • /
    • 1983
  • A comparison was made of a new serological method, thin layer immunoassay (TIA), and an established method, enzyme-linked immunosorbent assay (ELISA), in the detection and quantiacation of antibodies in clonorchiasis. Saline extract of Iyophilized Clonorchis sinensis adult worm was used as antigen, and TIA by the method of Elwing et at. (1976) and ELISA by Voller et at. (1974) were performed. Using sera from known clonorchiasis cases,100% of the sera tested were Positive by TIA and 88.35 by ELISA. TIA produced false positive results in 14 out of 36 cases, which were 10 amoebiasis cases, 16 paragonimiasis cases and 10 healthy controls. ELISA. however, produced a small number of false positives, 7 out of 55 cases. There was correlation between Immunoglobulin G level in sera and ELISA value (correlation coefficient, 0.69), whereas no correlation between Immunoglobulin G level and TIA result. The Performance of TIA and ELISA was not correlated in the results using homologous antigen.

  • PDF

Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor ($CO_2$ 2단 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.

Evaluation for Importance and Performance of Sanitary Characteristics by Bakers in Busan (부산지역 제과제빵종사자의 위생요인에 대한 중요도와 수행도 평가)

  • Kim, So-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.4
    • /
    • pp.602-612
    • /
    • 2010
  • This study was conducted to investigate the state of hygiene education aimed for by bakers, and the evaluations of the importance and the performance concerning sanitary characteristics by the bakers. The questionnaires were administered to 186 bakers in Busan and the data evaluated by 5 scales method of Likert were statistically analyzed. 20.4% of bakers have not received hygiene education. Only 32.8% of bakers have experienced hygiene education regularly. The more the bakers were educated, the more they practiced the contents of hygiene education. The major reason of education unfulfilment was due to insufficient equipments and facilities. The scores of the hygienic performance of educated bakers were significantly (p<0.05) higher than those of uneducated bakers in food sanitation, especially for sanitary characteristics on inspection, pre-preparation and distribution. The mean scores of the importance and the performance evaluated by bakers were 4.05/5.00 and 3.76/5.00, respectively. The bakers assessed the highest scores on the importance and the performance of personal hygiene. The gap score was -0.30 between the importance and the performance for sanitary characteristics. The baker recognized that sanitary management was not performed as much as they recognized its importance. The importance and the performance grid of bakers revealed that the items of checking the certification for the origin of new food ingredient, inspecting deliveries as quickly as possible, separation between preparing and breading time, thawing frozen food under running tap water/in refrigerator, separating disposal gloves and utensils by the purpose, putting products in cleaned and sterilized utensils, letting consumes know the expiration date of products, preventing a rubber hose from being left on the kitchen floor, checking insect nets frequently and so on showed lower scores compared to the mean scores of the importance and the performance. The levels of the hygienic performance by bakers were positively correlated (p<0.01) with the recognitions of the importance on sanitary characteristics. These results might provide basic data for hygienic training and play a role on the improvement of the sanitary management in bakery.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.