Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • In this paper, analysis on the performance characteristics of R744-R404A cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : It was observed that the highest COP of the system is achieved by higher superheating degree in R744 cycle than that in R404A cycle. The COP of the system increased by giving the subcooling degree in both cycles. The COP of the cascade system is the highest value when the system is operated at an optimum evaporation temperature.

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

기술현황분석 - 쥴톰슨냉동 기술

  • Hong, Yong-Ju;Go, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je
    • 기계와재료
    • /
    • v.23 no.3
    • /
    • pp.156-163
    • /
    • 2011
  • 쥴톰순 냉동기는 스터링 냉동기, GM 냉동기, 스터링형 및 GM형 맥동관 냉동기 등 기계적 극저온냉동기에 비해 단순한 구조, 수 초의 급속한 냉각특성을 장점으로 중대형의 가스액화사이클 뿐만 아니라 적외선검출기의 급속냉각, 저온수술 등 다양한 분야에서 널리 사용되어지고 있다. 일반적으로 100K 이하의 작동온도 및 수 초 수준의 빠른 냉각을 요구하는 적외선검출기의 냉각을 위해서는 수 백기압 이상 고압의 질소 및 아르곤 가스를 사용하는 쥴톰슨 냉동기가 주로 사용되고 있다. 쥴톰슨 냉동기는 핀-관(fin-tube) 형태의 열교환기와 열교환기의 구조적 기반을 제공하는 멘드렐(mandrel), 쥴톰슨 노즐 등으로 구성되며, 열교환기의 열전달 성능 및 유량조절기구의 특성은 냉동기 저온부의 냉각온도, 냉각시간 및 운전시간에 큰 영향을 미친다.

  • PDF

A Study on Performance and Reactor Behavior of Chemical Refrigerator (화학식 냉동기의 성능 및 반응기 거동에 관한 연구)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-95
    • /
    • 1997
  • A chemical heat pump based on the reversible reactions between metal chlorides and ammonia gas is attractive alternative to compression system and liquid absorption systems in cooling and refrigerating fields. The advantages of chemical heat pump are no regulatory constants due to CFC refrigerants, utilization of gas, industrial waste heat, electricity, fuel oil etc. as heat sources and wide applications to energy storage system, large-scale energy managements for industrial process. The scale-up of chemical heat pump from laboratory prototype to pilot plants necessitates the interpretation of system performance and evaluation of dynamic behavior in the chemical reactor. This study contains the prediction of performance of chemical refrigerator according to operating condition, the dynamic simulations through reactor modelling, which is used for the calculation of reactive medium temperature and the conversion variation with reactor cooling temperature, and the effect survey of block parameters on the power of refrigerator.

  • PDF

일본의 흡수식 냉동기 연구개발동향

  • 정종수;황규대
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.37-42
    • /
    • 2004
  • 흡수식 냉동기의 구성요소에 관한 성능향상 및 배열을 이용한 코제네레이션 시스템의 소개한다. 1997년 12월에 개최된 지구온난화 방지 교토회의(COP3-기후변동협조조약 제3회 체결국 회합)에서, 일본은 2008년-2012년까지 온실효과가스의 배출량을 1990년도 시점을 기준으로 6% 삭감하기로 합의하였다. 이러한 배경에 따라 $CO_2$ 배출량의 삭감에 대한 새로운 공업기술의 전개가 진행되고 있으며, 일본의 냉동공조산업 분야에서도 코제네레이션이라는 에너지 절약 관점으로부터 흡수식 냉동기가 다시 주목을 받게 되는 계기가 되었다.(중략)

  • PDF

Performance Analysis of an Ammonia(R717) and Carbon Dioxide(R744) Two-Stage Cascade Refrigeration System ($NH_3-CO_2$를 사용하는 이원 냉동 시스템의 성능 분석)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, cycle performance analysis of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the ammonia(R717) high temperature cycle and the carbon dioxide low temperature cycle. The main results were summarized as follows : The COP of two-stage cascade refrigeration system increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of two-stage cascade refrigeration system decreases with the increasing condensing temperature, but increases with the increasing evaporating temperature. And the COP of two-stage cascade refrigeration system increases with increasing the compressor efficiency. Therefore, superheating and subcoolng degree, compressor efficiency, and evaporating and condensing temperature of $NH_3-CO_2$(R717-R744) two-stage cascade refrigeration system have an effect on the COP of this system.

Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Study of Ethane Performance at Two-Stage Cascade Vapor Compression System (에탄을 사용한 2원 냉동 시스템의 성능 평가)

  • Rahadiyan, Lubi;Kim, Y.G.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.75-82
    • /
    • 2006
  • 세계적인 환경 보호 정책에 따라 할로겐화탄소 냉매를 대체할 환경 친화적인 초저온 냉매의 개발과 연구가 활발히 진행되고 있다. 일반적으로 캐스캐이드 2원 냉동 시스템에서 아직까지 할로겐화탄소 냉매가 널리 사용되고 있다. 탄화수소 화합물의 한 종류인 에탄은 낮은 지구 온난화 지수와 낮은 오존층 파괴지수를 가진 친 환경적인 자연 냉매이다. 본 연구는 지구 온난화 지수가 높은 R-23 냉매와 비교하여 캐스캐이드 2원 냉동 시스템에서 에탄의 성능 시험을 목적으로 수행 하였다. 1원측에는 R-22를 사용하였으며, 증발 온도에 따른 성능은 R-23 보다 에탄(R-170)이 더 높게 나타났다.

  • PDF

Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants (암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측)

  • Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids for 2-stage compression and 1-stage expansion refrigeration system. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of 2-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of 2-stage compression and 1-stage expansion refrigeration system using natural refrigerants have an effect on COP of this system. The COP of natural refrigerants was higher than the COP of freon R22 in this study, so points to be considered are the security, the attached facilities for natural refrigerants than COP.

A Dscussion for the Performance Improvement of Actual Regregeration Compressors (실용 냉동압축기의 성능향상 고찰)

  • 유동수;신승훈
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.979-984
    • /
    • 1993
  • 압축기는 냉동 . 공조 사이클에서 냉매를 압축하여 순환시키는 기능을 한다. 냉동 . 공조 사이클 에서 압축기의 효율 COP는 압축기 모터 입력에 대한 증발기에서의 냉각 능력의 비로서 정의 된다. 따라서 압축기 자체의 특성도 중요하지만 냉매의 열역학적 물성도 중요한 역할을 한다. 압축기의 효율향상문제가 최근에 대두되게 된 것은 첫 째, 몬트리올 협정에 의해 CFC의 사용이 제한되면서 새로 검토하게 된 대체냉매들의 열물성이 CFC보다 불리한 점과 둘째, 에너지 소비를 줄이려는 인식이 환경 측면에서 확산되고 있기 때문이다. 이 글에서는 압축기 효율을 결정하는 주요요소에 대하여 알아보고 최근 국내외에서 이루어지고 있는 효율향상 성과에 대하여 소개하 기로 한다.

  • PDF