• 제목/요약/키워드: 냉각탑성능

검색결과 42건 처리시간 0.019초

지하역사 실내형 냉각탑 성능개선 연구 (A study on an improvement of indoor cooling tower efficiency)

  • 배성준;황선호;신창헌;표수철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1726-1735
    • /
    • 2008
  • Seoulmetro has operated the air cooling equipment for 57 stations to improve services focused on our customers who use Seoulmetro during the summer season and has established every year. However, a new set of problems has arisen with the cooling tower to support a heat exchange of cooling water. The most important matter is loss of efficiency in the cooling tower. The leading cause of this problem is that we use an indoor type. As the cooling tower room is located in the underground of the city because of the residents near the station. Therefore It is difficult to establish the cooling tower on the ground. But it is unsuitable for the location requirements of the underground type because it has a limited space to set up the air cooling equipment, for example, the cooling tower and a ventilating opening. As a result of such an unfavorable condition, the cooling tower doesn't work efficiently and the warmth of cooling water because of insufficiency of a heat exchange and a refrigerator's technical obstacle such as a high-temperature and a high-pressure has arisen. To prevent this situation, the operator tend to reduce refrigerant. Accordingly, the efficiency of the air conditioning is getting lower and lower. Study wishes to analyze the matter to improve indoor cooling tower efficiency and recommend a best practice for a person who manage the establishment.

  • PDF

고성능액체크로마토그래피에 의한 Isothiazolinone Components의 분석에 관한 연구 (A Study on the Analysis of Isothiazolinone Components by High Performance Liquid Chromatography)

  • 김종규;이덕희
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.102-105
    • /
    • 1992
  • 냉각탑, 제지산업, 일반 산업용수 등에 사용되는 산업용 방부제의 유효 성분 isothiazolinone components 즉, 2-methyl-4-isothiazolin-3-one(unchlorinated compound)과 5-chloro-2-methy14-isothiazolin-3-one(chlorinated compound)을 고성능액체크로마토그래피로서 분리, 정량하였다. 역상의 C$_{18}$ column (15 cmX3.9 mm I.D.)을 사용하였으며 자외선 검출기의 파장 254 nm에서 methanol-0.4% acetic acid(40 : 60)의 이동상, methanol-0.4% acetic acid(30: 70)의 추출 및 주입용매 조건으로 HPLC 분리를 시도한 결과 unchlorinated compound는 10~32,400 mg/l 범위에서, 그리고 chlorinated compound는 120~107,400 mg.l의 범위에서 직선성을 보였다. 내부 표준물질로서 dimethyl phthalate를 사용하였으며, unchlorinated compound, chlorinated compound 및 내부 표준물질의 순서로 븐리가 일어났고 총 분리시간은 6.41분이었다. 상기의 조건으로 시험물질을 분석, 정량한 결과 예측농도치에 근접한 수치를 얻었다.

  • PDF