The Characteristic Study of Capacity Control of an Industrial Cooler Using an Invertor Compressor with Varing the Ambient Temperatures (인버터 압축기를 채용한 산업용 수냉각기의 외기온도 변화에 따른 용량제어 특성)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.238-243
    • /
    • 2011
  • The ambient temperature of the experimental conditions changes by varying the speed of the compressor and the electronic expansion valve opening. The effects of changing valve opening to the entire system has been investigated. The results show that the ambient temperatures of $35^{\circ}C$ and $30^{\circ}C$ controlled at 30Hz must be avoided. The capacity control range of the control compressor with changing speed is about 43~100% at $35^{\circ}C$, 43~100% at $25^{\circ}C$ and 48~100% at $10^{\circ}C$, respectively. The results show the capacity control range decreases with decreasing ambient temperature.

An Effect on the Solution Crystallization Temperature Difference and Cooling Capacity of the Absorption Chiller by a Solution Cooler in the Absorber (흡수기내 용액 냉각기가 흡수식 냉동기의 용액 결정화 온도차와 냉각 용량에 미치는 효과)

  • Chin, Sung-Min;Lee, Jae-Heon;Jurng, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1518-1523
    • /
    • 2003
  • The objective of the present work is to investigate an effect on the solution crystallization temperature difference and the cooling capacity of the absorption chiller by a solution cooler in the absorber. The cooling capacity of the absorption chiller can be higher, with the enhanced performance of the solution heat exchangers. But, because the solution crystallization temperature difference becomes smaller at the absorber inlet, the heat capacity of the solution heat exchangers might be limited by the danger of crystallization, which can cause the serious damages. In this paper, the heat capacity ratio of the solution cooler is defined as the ratio of the heat capacity of the solution cooler to that of the absorber. If it becomes larger in the additional type solution cooler, the solution crystallization temperature difference is augmented and the cooling capacity is also increased.

  • PDF

원전 출력감발 운전에 따른 방사성 부식생성물 거동 분석

  • 성기방
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.103-109
    • /
    • 1996
  • 고리 원자력 1호기 14주기(‘95년도) 운전기간 중 증기발생기 세관 열전달 용량 저하로 전출력 운전 기간동안 정격출력보다 15% 감발 운전한 경험이 있었는데, 이 기간중 냉각재내 방사성 부식생성물(CRUD) 농도가 약 80% 감소됨을 발견하였다. 이때 출력감소 비율보다 많은 CRUD 감소현상 규명을 위해 냉각재 수질관리인자와 EPRI 피복재 부식모델인 PFCC코드를 사용한 피 복재 산화물 두께변화 등을 비교한 결과, 운전중 용출되는 방사성 부식생성물은 핵연료 표면의 피복재 산화물에 흡착된 Co핵종이 피복재 산화물 이탈시 함께 거동하는 것으로 확인되었으며, 피복재 산화물 이탈은 산화막 두께 및 열유속에 주로 의존함이 밝혀졌다. 따라서 냉각재내에서 방사성 부식 생성물의 생성률 저감을 위해서는 정상운전시 핵연료 표면의 산화막 증가를 억제할 수 있는 수질 조건을 도출하고 그에따른 운전을 통해 원전 작업자의 방사선 피폭량 저감 및 방사성폐기물의 발생을 줄일 수 있을 것으로 여겨진다.

  • PDF

MIRIS 우주관측카메라 FM Dewar 설계

  • Cha, Sang-Mok;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Dae-Hui;Nam, Uk-Won;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Ga, Neung-Hyeon;Han, Won-Yong;Park, Jang-Hyeon;Seon, Gwang-Il;Yang, Sun-Cheol;Park, Jong-O;Lee, Seung-U;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.

  • PDF

Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor (1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석)

  • Quan, Dao-Van;Le, Tat-Thang;Sung, Hae-Jin;Park, Min-Won;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.31-41
    • /
    • 2018
  • This paper discusses a structure design and thermal analysis of cryogenic conduction cooling system for a high current HTS DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. Hence, we carried out the operating test of conduction cooling system of the 1st stage area with high current flow. The cooper bars was cooled down to 40 K and HTS leads operated stably. As a experiment result, the total heat load of the 1st stage area is 190 W. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Characterization of a TSV sputtering equipment by numerical modeling (수치 모델을 이용한 TSV 스퍼터링 장비의 특성 해석)

  • Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.46-46
    • /
    • 2018
  • 메모리 소자의 수요가 데스크톱 컴퓨터의 정체와 모바일 기기의 폭발적인 증가로 NAND flash 메모리의 고집적화로 이어져서 3차원 집적 기술의 고도화가 중요한 요소가 되고 있다. 1 mm 정도의 얇은 웨이퍼 상에 만들어지는 메모리 소자는 실제 두께는 몇 마이크로미터 되지 않는다. 수직방향으로 여러 장의 웨이퍼를 연결하면 폭 방향으로 이미 거의 한계에 도달해있는 크기 축소(shrinking) 기술에 의지 하지 않고서도 메모리 소자의 용량을 증대 시킬 수 있다. CPU, AP등의 논리 연산 소자의 경우에는 발열 문제로 3D stacking 기술의 구현이 쉽지 않지만 메모리 소자의 경우에는 저 전력화를 통해서 실용화가 시작되었다. 스마트폰, 휴대용 보조 저장 매체(USB memory, SSD)등에 수 십 GB의 용량이 보편적인 현재, FEOL, BEOL 기술을 모두 가지고 있는 국내의 반도체 소자 업체들은 자연스럽게 TSV 기술과 이에 필요한 장비의 개발에 관심을 가지게 되었다. 특히 이 중 TSV용 스퍼터링 장치는 transistor의 main contact 공정에 전 세계 시장의 90% 이상을 점유하고 있는 글로벌 업체의 경우에도 완전히 만족스러운 장비를 공급하지는 못하고 있는 상태여서 연구 개발의 적절한 시기이다. 기본 개념은 일반적인 마그네트론 스퍼터링이 중성 입자를 타겟 표면에서 발생시키는데 이를 다시 추가적인 전력 공급으로 전자 - 중성 충돌로 인한 이온화 과정을 추가하고 여기서 발생된 타겟 이온들을 웨이퍼의 표면에 최대한 수직 방향으로 입사시키려는 노력이 핵심이다. 본 발표에서는 고전력 이온화 스퍼터링 시스템의 자기장 해석, 냉각 효율 해석, 멀티 모듈 회전 자석 음극에 대한 동역학적 분석 결과를 발표한다. 그림1에는 이중 회전 모듈에 대한 다물체 동역학 해석을 Adams s/w package로 해석하기 위하여 작성한 모델이고 그림2는 180도 회전한 서브 모듈의 위상이 음극 냉각에 미치는 효과를 CFD-ACE+로 유동 해석한 결과를 나타내고 있다.

  • PDF

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

Development of Web Based Infrastructure Capacity Calculator (웹 기반의 기반시설 소요용량 계산기 개발)

  • Sung, Jin-Woo;Koh, Dong-Gun;Kang, Ji-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.2-4
    • /
    • 2014
  • 단일 프로세서의 성능 향상과 여러 개의 프로세서를 하나의 시스템으로 구성하는 고성능컴퓨터 제조 기술의 발전은 컴퓨터의 성능 향상에 크게 기여하였다. 고성능컴퓨터를 안정적으로 운영하고 효율적으로 관리하는데 영향을 미치는 대표적인 환경변수는 전원, 냉각, 공간이다. 이러한 환경변수는 데이터센터 기반시설 설계 단계에서부터 정확한 용량산정이 이루어 져야 한다. KISTI 슈퍼컴퓨팅서비스센터에서는 1969년부터 컴퓨터 시스템을 운영하여 왔으며, 특히, 슈퍼컴퓨터 시스템은 1988년의 슈퍼컴 1호기를 시작으로 현재는 슈퍼컴 4호기 시스템을 운영하고 있다. 많은 운영경험을 바탕으로 웹 기반의 기반시설 소요용량 계산기를 개발하였다.