• Title/Summary/Keyword: 냉각손실

Search Result 198, Processing Time 0.027 seconds

A study on the Dynamic Mechanical and Dielectric Loss according to Quenched Condition in Low Density Polyethylene fer Power Cable (전력 케이블용 저밀도 폴리에틸렌의 냉각 조건에 따른 기계적 및 유전손실에 관한 연구)

  • 김재환;권병휘;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.5
    • /
    • pp.27-37
    • /
    • 1992
  • We studied the dielectric and dynamic mechanical losses according to the quenching condition in low density polyethylene being used to power cables. According to severe quenching condition, characteristics of the temperature in internal friction los peak have decreased the magnitude of loss peak as amorphous region lengthen. From now on, the frequency dependent characteristics of dielectric loss have investigated at room temperature, and the dielectric loss peak due to interface polarization, between crystal and amorphous region, occurs about 30[Hz], and that, the peak due to orientation polarization in correspondence to the loss peak in internal friction has observed at about 3 [MHz]. As quenching velocity increased, the effect on quenching condition about the dielectric loss has decreased the magnitude of the loss peak. Thus, estimation has been carried out on the activation energies nd the degree of crystallinity by means of X-ray diffraction are obtained as follows: room quenching : 26.4 [kal/mole] and 54.73 [%], ice quenching : 25.6 [kcal/mole] and 48.47 [%], liquid nitrogen quenching specimens : 22.56 [kcal/mole] and 40.95 [%].

  • PDF

펄스레이저를 이용한 $MgTiO_3$ 박막의 성장과 전기적 및 구조적 특성에 관한 연구

  • 한근조;임왕규;이재찬
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.86-86
    • /
    • 1999
  • 본 연구에서는 마이크로파 유전체 소자로서의 응용 및 절연 산화막으로의 응용을 위해 마이크로파 유전체 세라믹으로 사용되어 온 MgTiO3 물질을 펄스 레이저로 박막을 제조하였다. MgTiO3 는 주로 고주파에서 높은 유전율을 갖고 높은 품질계수 (22.000 at 5 GHz) 혹은 낮은 유전손실을 갖으며 유전특성의 온도 안정성이 우수하여 유전체 세라믹 재료로 응용된다. MgTiO3 박막의 성장은 KrF(파장:248nm) 엑시머 레이저를 이용했으며 공정조건으로 박막의 성장온도는 500-75$0^{\circ}C$, 산소 압력은 10-5-200mTorr, 성장 후 냉각시 산소분위기는 200Torr, 레이저 에너지 밀도는 1.5-5J/cm2 등의 조건으로 박막을 성장하였다. MgTiO3 박막을 여러 가지 기판, 즉 Al2O3(r-plane), Si, Pt 위에 성장시켰으며 기판에 따라 에픽텍셜 혹은 다결정 상태를 갖는 ilmenite 구조로 성장되었다. PLD(Pulsed laser deposition)법에 의해 형성된 MgTiO3 박막을 보면, 우선 Al2O3(r-plane) 기판위에 성장된 경우 $700^{\circ}C$에서 에픽텍셜하게 성장하였으며, Si 기판 위에 성장된 경우 $650^{\circ}C$에서부터 (003)면으로 우선 배향된 단일상의 ilmenite 구조가 형성된다. Ptdnl에 성장된 경우 $600^{\circ}C$에서부터 (003)면으로 우선배향성을 가지며 $650^{\circ}C$에서 결정의 안정화를 이루었으나, MgTiO3 박막은 전기적 특성으로 유전특성 및 유전분산 특성 등이 측정 분석되어 MgTiO3 박막의 고주파 유전체로의 응용에 관한 가능성을 토의하였다.

  • PDF

Development of New Model(Dome Type) Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 신모델(돔형) 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.182-187
    • /
    • 2002
  • 국내 저온저장고의 주류를 이루고 있는 컨테이너 박스형 저온저장고의 문제점은 재래식 제어방식으로 인한 성능저하 외에도 자체 구조적인 설계상의 문제점을 가지고 있다 이러한 구조적인 문제점을 열거하면 다음과 같다. 첫째, 한 축 방향에 설치되어있는 유니트 쿨러에서 토출되는 냉기에 의해 저장고 내의 공기를 냉각하는 형태이기 때문에 냉기의 분포가 고르지 못하여 균일한 온도 분포를 이루기 어렵다는 단점을 가지고있다. 둘째, 한 축 방향에서 토출되는 냉기가 맞은 편 벽면까지 도달해야 하기 때문에 풍속이 강해야 하며 이로 인해 저장 청과물이 냉해를 쉽게 입고 심한 증산작용에 의해 쉽게 표면건조나 중량감소를 가져온다. 셋째, 천장부와 측벽부가 90$^{\circ}$의 경사각을 가지고 있어 공기의 유동이 원활하지 못하여 에디현상으로 인한 온도나 풍속의 불균일 구간을 피해서 청과물을 저장해야 하기 때문에 그만큼 버려지는 공간이 많아 비경제적이다. 넷째, 위와 같은 문제점들 때문에 중ㆍ대형의 저온저장고를 컨테이너 박스형으로 설비 할 경우 보다 심한 온도 불균일과 냉기유동 분포를 보여 경제적인 손실이 더 커지게 되는 악순환을 낳게된다. 이에 따라 본 연구에서는 국내 저온저장고의 구조적인 설계상의 문제점을 인식하고 이를 해결하고자 3차원 CFD 시뮬레이션을 이용하여 저온저장고의 새로운 모델을 설계하였다. 이론 바탕으로 직접 저온저장고의 시작기를 개발하여 저장고 내부의 역 유동과 난류유통을 해석하였다. (중략)

  • PDF

양성자 빔을 이용한 의료용 방사성동위원소 C-11과 Tc-99m 개발

  • Kim, Jae-Hong;Lee, Ji-Seop;Park, Hyeong;Jeon, Gwon-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.235-235
    • /
    • 2011
  • 진단용 또는 의료용 동위원소들은 안정한 표적물질에 높은 에너지의 양성자가 조사 될 때 핵반응에 의해서 생성된다. 양성자를 충분한 에너지로 가속하기 위해서 이용되는 사이클로트론의 주요 부분은 (1) 진공시스템, (2) 자석시스템, (3) RF 시스템, (4) 외부 이온원, (5) 수직 축 방향빔의 수평방향 전환 시스템, (6) 빔 인출 장치, 그리고 빔전송과 표적장치로 구성된다. 인출된 빔은 표적까지 손실 없이 전송 될 수 있도록 빔 라인에 설치된 광학적 요소에 의해 집속되어 전송된다. 방사성동위원소의 생산량은 양성자 빔의 특성과 표적 물질의 종류에 따라 결정된다. 즉, 표적 물질에 조사하는 입자의 종류, 적절한 핵반응 선택, 최소량의 불순핵종과 원하는 방사핵종의 최대수율을 얻을 수 있는 최적 에너지 범위결정, 표적 물질의 냉각능력과 입자전류의 세기 등을 고려 하여야 한다. 동위원소 생산에 있어서 예측되는 수율은 입자전류와 비례하며, 에너지에 대한 핵반응 단면적 즉, 여기함수를 적분하여 아래와 같이 얻을 수 있다. 주 생성핵종의 생산 효율을 최대로 높이고 불순 핵종의 생성량을 최소로 감소시키기 위해서는 정확한 여기 함수 자료를 바탕으로 최적 입자를 결정하여야 한다. 또한 이론적인 생산 수율은 입자 전류에 정비례하지만, 입자 전류가 클경우 생산수율은 이론적인 수율보다 적다. 입자빔의 불균일성, 표적의 방사선 피폭에 의한 손상, 높은 입자전류에 의해 발생하는 열로 인하여 생성 핵종이 증발하여 생산 수율이 감소된다. 본 발표에서 방사핵종 C-11과 Tc-99m을 개발하기 위한 최적 조건에 관한 연구결과를 보고하고자 한다.

  • PDF

Characteristics of the Functional Panel Made from Foamed Aluminum (발포알루미늄을 이용하여 제조한 기능성 판넬 특성 연구)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2006
  • In this work, the properties of environmentally friendly functional panel made from waste aluminum were investigated. Product quality enhancement was pursued through an improved viscosity process, a mixing process by agitating, a foaming process, a cooling process, and a color addition process. An acoustic transmission attenuation test, a sound adsorption rate measurement test, and a foaming condition and scrap mixing test were implemented. As a result, the functional panel made from waste aluminum was ultra lightweight and had excellent properties such as soundproof, sound interception, and shielding harmful electromagnetic waves. Also, the functional panel showed low thermal conductivity (about 2.2 kcal/mh) and excellent heat-insulating property.

Long-term load cycle test of the HTS cable system (초전도케이블의 장기 부하변동시험 및 성능평가)

  • Lim, Ji-Hyun;Sohn, Song-Ho;Yim, Seong-Woo;Sung, Tae-Hyun;Hwang, Si-Dole;Choi, Ha-Ok;Yang, Hyung-Suk;Ma, Yong-Hu;Ryu, K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.300-300
    • /
    • 2008
  • 우리나라의 전기에너지 수요가 지속적으로 증가함에 따라 새로운 송배전 선로의 구축이 필요하다. 하지만 현재 도심지의 전력구에는 더 이상의 지중선의 증설은 불가능하며 가공선 설치의 경우 환경 민원의 부담을 떠안게 된다. 그래서 기존 동도체의 회선당 송전 한계를 극복하고 대용량 송전 및 손실을 크게 줄일 수 있는 초전도 케이블의 연구가 세계적으로 활발히 진행되고 있다. 한국전력 전력연구원은 신 전력시스템으로서의 22.9 kV급 초전도케이블 시스템을 고창전력시험센터에 설치하고 운영 및 유지 보수 과정을 통하여 실제 계통 적용을 위한 최적 운전조건을 연구하고 있다. 이 논문에서는 실제 부하 상황을 모의하기 위하여 초전도케이블의 장기 부하변동 시험에 따른 케이블 송전 능력 확인 및 냉각시스템의 반응성을 살펴보고 부하변동 시험 후 초전도케이블 도체 열화 여부를 확인하기 위하여 직류 임계전류를 측정하였다. 그 결과 부하변동 시험 전의 임계전류 값과의 변화율이 삼상 모두 ${\pm}1$% 내외로서 오차범위를 벗어나지 않으므로 건전한 것으로 판단되었다.

  • PDF

A Study on the Design and Performance of a Prototype Pumping Skid for Resonant Frequency Control in the PEFP DTL (PEFP DTL 가속장치의 공진주파수 제어를 위한 펌프장치의 설계 및 성능에 관한 연구)

  • Kim, Kyung-Ryul;Park, Jun;Kim, Hyung-Gyun;Kim, Hee-Sub;Hwang, Woon-Ha;Yoon, Jong-Cheol;Lee, Mong-Su;Cho, En-Byul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2064-2069
    • /
    • 2008
  • The Resonance Control Cooling System (RCCS) prototype installed in KAERI site has been designed to control the resonant frequency of the normal conducting drift tube linac (DTL) for the Proton Engineering Frontier Project (PEFP). The RCCS water pumping skid is composed of two channels as a by-passing the cooling water and a plate heat exchanger. The required temperature can be achieved by mixing both channels in order to control its the resonant frequency at 350 MHz. The temperature controlled water pumping skid operates in combination with the Low Level Radio Frequency (LLRF) system. We have discussed the design, modeling with each components, control scheme, fabrication and test results of the water pumping skid for resonant frequency control of the DTL cavity. In conclusion, the fabricated RCCS prototype through the optimization of modeling has corresponded with the design requirement and concept.

  • PDF

An effect of design parameters f water injection slincer on the characteries of noise generated by Liquid Rocket Engine (물분사형 소음기의 설계변수가 액체로켓엔진 소음특성에 미치는 영향)

  • Park, Hee-Ho;Cho, Byung-Sun;Kim, Yoo;Ji, Pyung-Sam;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.26-26
    • /
    • 1998
  • 우주항공 산업에 대한 관심 증가에 따라 지상에서 많은 연소시험을 시행하고 있으나, 소음 발생문제에 부딪혀 어려움을 겪고 있는 실정이다. 따라서 초보적 단계이기는 하나, 액체로켓 엔진의 추력 손실을 최소화시키고 최대한 제트 소음을 크게 줄일 수 있는 소음기를 연구, 개발하고 있다. 본 연구에서는 제트소음에 대한 기초연구를 수행하여 물분사형 소음기를 설계 및 제작하였고, 물분사량과 소음기의 기하학적형상이 소음 특성에 미치는 영향을 연구하였다. 본 실험범위에서 연구의 결과는 다음과 같다. 1. 동일한 물 분사량 조건에서, 소음기 길이가 노즐출구 직경의 10배 모델 보다 30배 모델이 9dbl 정도 감음효과를 보였다. 2. 불 분사량이 증가함에 따라 소음레벨은 감소하였고, 30배 모델의 경우 불분사량이 배기가스의 10-12배 조건에서는 소음레벨을 91dbl까지 줄일 수 있었다. 3. 상기조건(소음레벨 91dbl)에 확장관을 부착함으로써, 소음레벨을 약 86dbl까지 줄일 수 있었다. 4. 본 형태의 물분사방식을 채택할 경우 고온배기가스로 인한 소음기의 파손을 방지하기 위해서 반드시 막냉각장치의 설치가 요구된다.

  • PDF

Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used (배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Jang, Seok-Soo;Yeo, In-Dong;Choi, Jong-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4602-4609
    • /
    • 2013
  • In summer and winter, the difference between the temperature during the day and that during the night is high, which leads to various problems during concrete placement, such as cracks and defects in the concrete as well as low durability and strength. Although nuclear power plant concrete is widely used for placement in all seasons, particular attention must be paid to its quality during the summer. Therefore, we evaluated the effects of a cooling method for mixing water, which is a commonly used hot weather precooling method, and the use of a retarder, on the characteristics of Nuclear Power Plant concrete. In the cooling method for mixing water, cold water at 5 was used, with 50% of the water content consisting of ice flakes. The effects of using a retarder were evaluated by reviewing the characteristics of the cement at the unset stage and after hardening. To evaluate the characteristics of the unset cement, we measured the slump, air volumes, setting times, and pressure strengths after hardening. Furthermore, we measured the heat of hydration at different temperatures; the loss of heat was minimized using insulation. Both the slump time and the complete ageing time of the air volume were found to be 120 min at $20^{\circ}C$ and 40 min at $40^{\circ}C$. In the case when the cooling method for mixing water was used and in the case when a retarder was used, the initial and final sets by penetration resistance were delayed, and the delay decreased with increasing air temperature. For the heat of hydration, the cooling method for mixing water not only lowered the maximum temperature but also delayed its attainment. However, the use of a retarder had no effect on the maximum temperature. Moreover, in the early ages (e.g., 3 and 7 days), the pressure strength of the concrete was lower than that of plain cement. However, the strength of 28-day concrete met the standard construction specifications.

A Quality Assurance Study for the Application of Cook/Chill System in School Foodservice Operation (II) - Pork Bulgogi (Broiled Sliced Pork with Sauces) - (학교급식에 Cook/Chill System 적용을 위한 품질보증연구(II) - 돼지불고기 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.319-331
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point plan applicable to cook/chilled Pork Bulkogi (broiled sliced pork with sauces) in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. During the product flow, time-temperature profile was recorded and microbiological analyses including mesophilic and psychrotrophic total plate counts, coliform, and fecal coliform and qualitative analyses of Salmonella and Listeria monocytogenes were done. Chemical analyses (pH, acid value, total volatile basic nitrogen), sensory evaluation, and quantitative analysis of thiamin were conducted for 5 days of chilled storage. The number of mesophiles in raw pork ($4.26{\pm}0.11\;Log\;CFU/g$), seasoning mixture ($5.97{\pm}O.04\;Log\;CFU/g$) and marinated pork ($5.56{\pm}0.21\;Log\;CFU/g$) were below the microbial standards for "requires further cooking" food items. Listeria monocytogenes was detected in seasoning mixture. After heating, the number of mesophiles ($5.17{\pm}0.04\;Log\;CFU/g$) were slightly reduced but it did not meet the microbial guidelines of $5\;Log\;CFU/g$ for "ready-to-eat" foods. No other microbes including pathogens were detected. By reheating the menu item after chilled storage, the number of mesophiles were reduced in every phase of 1st day ($4.62{\pm}0.22\;Log\;CFU/g$), 3rd day ($4.55{\pm}0.20\;Log\;CFU/g$) and 5th day ($4.25{\pm}0.16\;Log\;CFU/g$) of chilled storage, and the number of microbes was below the standard limits for "ready-to-eat" foods. At the fifth day of chilled storage, pH (p<0.05), acid value (p<0.01) and TVBN (p<0.05) showed significant increases. Sensory evaluation results did not show any significant change for 5 days of chilled storage. Thiamin content showed a decrease for 5 days of chilled storage. Consequently, the ideal shelflife recommended for Pork Bulkogi was within 3 days of chilled storage. CCPs for Pork Bulkogi were purchasing and receiving of raw meat and some seasoning ingredients, heating, chilling, chilled storage, reheating, and distribution.

  • PDF