• Title/Summary/Keyword: 내화설계

Search Result 179, Processing Time 0.028 seconds

Convergence Technique Study through Simulation Thermal Analysis due to the Shape of Electric Heater (전기 히터의 형상에 따른 시뮬레이션 열 해석 연구를 통한 융합 기술 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.241-246
    • /
    • 2015
  • In cold winter season, the apparatuses of heating and heater which warm up the interior of a room are necessary element and the used amount of these apparatuses from the year 2000 has been increased abruptly. But, the fire accident and the danger of fire are also increased. Therefore, 3D modelling is done by referring three kinds of the electric heaters as the heaters of ceramic, carbon and near infrared ray sold in the city for the design of more safe heating apparatuses in this study. The thermal analyses with these models are carried out and the durabilities due to the thermal deformation and stress are studied. By the background of the study results derived in this study ultimately, the durabilities of electric heater models due to each shape can be anticipated and contributed to the development of new heating apparatus with more safe resistance to fire. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP (GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가)

  • Ryu, Jae-Ho;Park, Se-Ho;Ju, Young-Kyu;Kim, Sang-Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2011
  • To obtain a lower story height with a long span and better fire resistance, a new composite floor system using GFRP (glass-fiber-reinforced plastics) was proposed. This floor system consists of asymmetric steel with a web opening, a hollow core ball, concrete, and GFRP. To evaluate the flexural performance of the new composite floor system, an experiment was conducted. The test parameters were the presence of GFRP, the void ratio in relation to the hollow core balls, and the web opening. The test results showed that the resistance and stiffness of the specimen with GFRP were 10% higher than those of the reference specimen, and that fully composite action was accomplished up to the yielding point. After the attainment of the yield strength, the ductility of the specimen was reduced due to the stress concentration around the web openings. The slip between the concrete and steel beam, however, was small. Thus, in the design of the proposed new floor systems, it is desirable that the calculated resistance be reduced by 15%, for safety.

Design and Test of Slag Tap Burner System for Prevention of Molten Slag Solidification in Coal Gasifier (석탄가스화기 용융슬랙의 고형화 방지를 위한 슬랙탭 버너시스템 설계 및 시험)

  • Chung, Seokwoo;Jung, Kijin;Lee, Sunki;Byun, Yongsu;Ra, Howon;Choi, Youngchan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.74.2-74.2
    • /
    • 2011
  • 석탄가스화 기술은 고온, 고압 조건에서 석탄과 산소의 불완전연소 및 가스화 반응을 통해 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이다. 석탄가스화기 공급되는 석탄은 산소와의 부분 산화, 수증기 및 $CO_2$와의 반응에 의하여 합성가스로 전환되는데, 일반적으로 슬래깅 방식 석탄가스화기의 정상운전 중에 가스화기 내부 온도는 $1,400{\sim}1,600^{\circ}C$ 정도의 고온이며, 운전압력은 20~60 기압으로 매우 고압 상태에서 운전이 이루어지는데, 공급되는 석탄 시료의 성분들 중 가연성 물질의 99% 이상이 합성가스로 전환되는 반면, 회분에 해당되는 무기물의 대부분은 용융 슬랙 형태로 가스화기의 벽을 타고 흘러내리다가 슬랙탭을 통해 하부의 냉각조로 떨어지면서 급냉이 이루어지게 된다. 그러므로, 석탄가스화기 정상운전중 슬랙탭 주변의 온도를 고온으로 유지함으로써 용융슬랙의 고형화를 방지하는 것은 석탄가스화기의 안정적인 연속운전을 위하여 중요한 기술 중의 하나라고 할 수 있다. 따라서, 본 연구에서는 저급탄 가스화를 위한 1 톤/일급 고온, 고압 습식 석탄가스화기의 정상운전중 슬랙탭 부근에서 용융슬랙의 고형화를 방지하기 위한 슬랙탭 버너시스템의 설계를 진행하였으며, 안정적인 운전조건 도출을 위하여 보조연료(CNG)와 산소의 공급비율에 따른 화염특성 시험을 진행하였다.

  • PDF

The CTD Evaluation or Simple and Iterative Task through the Improvement of Working Conditions (작업환경개선을 통한 단순반복작업의 누적외상평가)

  • 서승록;임완희
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.6 no.4
    • /
    • pp.12-21
    • /
    • 2001
  • Recently, as work strength is deepened, as well, labor environments is changed, simple and iterative worker's Cumulative Trauma Disorders(CTD) is gradually being increased. Accordingly, this study was designed to represent its system design to carry out their iterative and simple task by machine through the difference of muscle fatigue between worker on handling line and worker under the work environments by Air Balance System for the purpose of analyzing their muscle fatigue test according to fulfillment of iterative and simple task. From the result of this study, with regard to the comparison of muscle fatigue between work on handling line and work on automation line on the occasion of refractory brick loading, their muscle fatigue extent under the work environments by Air Balance system was lower than it of handling by AMEG(64.1%), MF(65.3%), MPF(64.3%), ZCR(63.6%) respectively. And also, generally there showed similar transfer at the aspect of muscle mobilization. In other words, we can say that work environments by Air Balance System is beneficial at the aspect of alleviating works' fatigue extent on handling line. As well, the result of this study shows that worker's exposure to Cumulative Trauma Disorders(CTD) is relatively low.

  • PDF

Pipe Stiffness Prediction of GRP Flexible Pipe (GRP 연성관의 관강성 예측)

  • Lee, Young-Geun;Kim, Sun-Hee;Park, Joon-Seok;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.18-24
    • /
    • 2011
  • In this paper, we present the load-deflection behavior of GRP pipes. GRP buried pipes are widely used in construction in the advantage of their superior mechanical and physical characteristics such as high chemical resistance, high corrosion resistance, right weight, smooth surface of the pipe, and cost effectiveness from soil-structure interaction. To design flexible pipes to be buried underground, it should be based on the ASTM D2412(2010). When applying ASTM D 2412(2010) to the design, pipe stiffness(PS) must be predetermined by the parallel-plate test which requires tedious and laborious working process. To overcome such problems, the finite element simulations for finding the load-deflection behavior of the GRP flexible pipes is installed at UTM testing machine. In the finite element simulations, basic data, such as the modulus of elasticity of the material and cross-sectional dimension, is used. From the investigation, we found that the difference between experimental result and analytical prediction is less than 15% when the pipe deflected 3% and 5% of its vertical diameter although the pipe material is not uniform across the cross-section.

A Study on P-M Interaction Diagram of Fire-Damaged High Strength Concrete Column (화재 피해를 입은 고강도 RC 기둥의 P-M 상관곡선에 관한 연구)

  • Kim, Hyun-Jung;Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.257-260
    • /
    • 2008
  • This study will make P-M interaction diagram of residual capacity at fire-damaged High strength concrete column with polypropylene fiber. Evaluating capacity of column decreasing spalling with P-M interaction diagram is important. because high strength concrete column with polypropylene fiber isn't section area loss. P-M interaction diagram that is made to analyze according to a various parameters is useful index for design and evaluating capacity of columns. In this study, spalling, temperature distribution of interior column, residual strength and movement of column in eccentric loading are studied with expose time of high temperature. For study fire test that is similar real act, and after cooling in normal condition residual strength of specimen is estimated. And this study use DIANA(Displacement Analyzer) for analyzing nonlinear analysis. with experiment temperature and strength data.

  • PDF

Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior (CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가)

  • Choi, Ji-Su;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.174-179
    • /
    • 2021
  • Currently, fluid transfer steel pipes take a lot of time and expense to maintain all facilities due to new construction and painting or corrosion and aging. Therefore, this study was conducted for designing a CFRP pipe structure with high corrosion resistance and chemical resistance as a substitute for steel pipes. The helical/hoop pattern was cross-laminated to improve durability, and HNT was added to suppress the moisture absorption phenomenon of the epoxy. The HNT/CFRP pipe was manufactured by a filament winding process, and performed a mechanical property test, and a moisture absorption test in distilled water at 70℃. As a result, the highest bending strength was obtained when the hoop pattern was laminated with a thickness equivalent to 0.6% of the pipe. The 0.5 wt% HNT specimen had the highest moisture absorption resistance. Also, the delamination phenomenon at the interlayer interface was delayed, resulting in the lowest strength reduction rate.

The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material (외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl;Kim, Jung-Hyun;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.85-91
    • /
    • 2012
  • To reduce human life and property damage at the fire in a building, it is most critical to control flame spread in the early stage. Fire spread prevention measure generally includes fire resistance performance securing of structure member in the arson zone and use limitation based on combustion performance of finishing material. The latter is most fundamental fire safety design to determine flame spread, but domestic combustion test determines combustion performance by specimen sized fire test method. Thus, there are many restrictions in the determination of combustion performance by composite material such as sandwich panel. Especially, outer finishing material uses a variety of composite material such as dry bit, aluminum composite panel, and metal panel compared to inner finishing material. Therefore, this study would determine vertical fire spread features by a full scaled fire experiment through the test method of ISO 13785-2, an international test standard.

Basic Test on the Mechanical Characteristics of Polyester Membrane (폴리에스터 막재의 역학적 특성에 관한 기초시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Lee, Jang-Bok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of architectural membrane have fire proofing, lack of strength, tear resistance, durability and elasticity. For the estimation of this problems, it will be tested the basic mechanical properties of membrane material about tensile strength, tearing resistance and repeated loading behavior. Elastic modulus is 337.30~1257.63N/$mm^2$, and strain is 17.90~26.91%.

  • PDF

Review of Spatting Effect on Concrete Element in Fire (화재시 콘크리트 요소 폭렬영향성 고찰)

  • Kim, Hyung-Jun;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.54-63
    • /
    • 2007
  • Concrete is generally accepted to have good inherent fire resistance. It mainly relies on the assumption that concrete has low heat-transfer characteristic and spatting does not occur during the course of a fire. However, the significant numbers of fire accidents have shown in recent years that incidence of spatting has caused sever damages to many structures. This review has systematically investigated the behaviour of concrete in fire, including phenomenon of spatting, with respect to the theorical consideration and experimental results. Explosive spatting is caused by the build-up of water vapor pressure in concrete subjected to increasing temperatures. When this pressure exceeds the tensile strength of the concrete over a fire-exposed area, explosive spatting can result in a typical temperature range between $200^{\circ}C\;and\;400^{\circ}C$. The major functions are known to be moisture content, pore pressure, load ratio, and heating regime.