• Title/Summary/Keyword: 내부 온/습도

Search Result 181, Processing Time 0.028 seconds

Experimental Study of Internal Distribution of Temperature and Relative Humidity in Notebook LCD Module (노트북용 액정 모듈 내부의 온도 및 상대 습도 변화에 관한 실험적 연구)

  • Kim, Tae-Woo;Kim, Gi-Bin;Lee, Jae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.217-221
    • /
    • 2012
  • As a part of basic research to improve screen quality, which deteriorates when strain occurs within optical sheets in LCD modules for laptop computers, a measurement system is needed to analyze the influence of heat and moisture, which are the main factors causing the strain. It is assumed that the existence of an air gap less of than 0.5 mm inside the LCD module causes humid air from outside to permeate through the module. To investigate this phenomenon, in this study a thin printed circuit board (PCB) of compact sensors that measure temperature and humidity is inserted into LCD modules, and thus, the changes in temperature and humidity can be analyzed in real time. The results can be used as basic data for simulation of the deformation behavior and structural design of LCD modules in the future.

Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning (간헐공조 전시관내 유물 진열장의 온·습도 환경 분석)

  • Lee, Sun Myung;Lim, Bo A;Kim, Seojin
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.311-320
    • /
    • 2013
  • The showcase has insufficient temperature control, but it has excellent humidity control. The annual average temperature and relative humidity inside the showcase was $18.8^{\circ}C$ and 60.3%, respectively, and the showcase showed lower temperature and higher humidity than the exhibition room. The temperature inside the showcase appeared with high variation according to the seasons, while relative humidity was ranging from 59% to 61% regardless of the seasons. The showcase showed high temperature and humidity likewise the exhibition room in summer. In addition, lowering of temperature was elevated relative humidity according to the operation of air conditioner in summer. A moisture problem occurred because the temperature and humidity differences between the exhibition room and showcase were large according to the operation of air conditioner in winter. PI for temperature and relative humidity inside the showcase is 18.0%, and it means conservation environment for exhibition is unsuitable. In particular, continuous management of temperature and humidity inside the showcase is required because PI in the summer and winter is less than 1.0%.

Changes in Temperature and Humidity in the Forest Caused by Development (도로에 의한 산림 내 온습도 변화)

  • Choi, Jaeyong;Park, Myung-Soo;Kim, Su-Kyung;Yu, Seung-Hyeon;Choi, Won-Tae;Song, Wonkyong;Kim, Whee-Moon;Kim, Seoung-Yeal;Lee, Ji-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.604-617
    • /
    • 2018
  • As the depletion of forests became more widespread due to the increase in the number of roads, the research was conducted on the relationship between temperature and humidity in the forests, assuming that the forests around the roads were affected. Through the forest monitoring, the temperature and humidity of coniferous forests and broadleaf forests in Sedong and Gongju areas were observed at three point of 10m, 20m and 30m from the road boundary to the inside of the forest, respectively. In Yeongdong area, for more reliable results, it was observed from the point of 0m, 10m, and 20m. During the study period, so it was expected the change in tree growth was small, the change of temperature and humidity inside the forest by the road was compared with the temperature and humidity from the road to the inside of the forest from September 2017 to January 2018, the changes of temperature and humidity inside the forest due to linear development such as roads were quantitatively analyzed. Using the HOBO data logger (MX2301, Onset Corp.), the temperature and humidity changes of each site were measured, and the average of the changes have been analyzed monthly. In the case of Gongju coniferous forests in September 2017, the average weekly temperature is $0.57^{\circ}C$ higher than the forest outside from the forest boundary and $1.23^{\circ}C$ higher than the inside of the forest, at night in November 2017, in Sedong broadleaf forests. That is, the ability to control the temperature and humidity of the forests along the road was larger and less variable as the distance from the road boundary to the inside of the forest increased. In this study, it is considered that the high degree of change in temperature and humidity of the forest and the surrounding area due to artificial linear development such as roads will affect the growth of trees. This results could serve as a basis for studying the quantitative scope of linear development affecting forest growth and for managing forest change caused by linear development.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Evaluation of Temperature and humidity changes in Concrete (콘크리트 내부의 온.습도 평가)

  • Park, Dong-Cheon;Yun, Eun-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.235-236
    • /
    • 2010
  • The temperature and humidity in concrete changes differently depending upon factors such as exposure direction, W/C and external environment conditions. The temperature and humidity are also different depending upon internal depth of concrete. In this study We've evaluated the change of the temperature and humidity in the concrete based upon the factors we mentioned above for two years, analyzed these measured results and reviewed the results theoretically.

  • PDF

Operation Characteristics of the HVAC System Installed in Ancient Tomb (고분내부에 설치된 공조시스템의 운전특성)

  • Jun, Yong-Du;Lee, Kum-Bae;Jun, Hee-Ho;Ko, Seok-Bo;Park, Jin-Yang;Youn, Young-Muk
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.202-208
    • /
    • 2006
  • Although the importance of good conservation of historic sites including ancient royal tombs is well aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the general understanding about the environment of the underground space or tombs is not satisfactory. In the present study, vibration levels due to the operation of an HVAC system to maintain the desired indoor temperature and humidity are investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the indoor unit inside, showed order of magnitude less values than the Swiss Standards, but still higher than the value suggested by German standards, which is, zero. Further study will be pursued for cases including different ways of installation, because the vibration level depends not only on the system design, but also on the installation methods.

A Design and Implementation of Chick Incubation System Based on IoT

  • Sejong Lee;Sol Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.9
    • /
    • pp.179-186
    • /
    • 2024
  • In this paper, we design and implement an Internet of Things (IoT)-based chick incubation system. The system consists of three key components: the IoT incubator, the IoT server system, and the smartphone application. The IoT incubator is composed of an Arduino board, temperature and humidity sensors, a temperature and humidity controller, a ventilation controller, and an egg turning controller. The temperature and humidity sensors measure the temperature and humidity inside the IoT incubator and send the data to the temperature and humidity controller on the Arduino board. Additionally, it provides the function of transmitting temperature, humidity, and control history data to the IoT server via WiFi. It also offers automatic control of ventilation, egg turning, and temperature and humidity on a daily basis. The IoT server system receives data from the incubator, stores it in a database, and provides query data upon request from the smartphone. The smartphone application retrieves historical data through the server and monitors the temperature and humidity data of the IoT incubator in real-time, controlling the IoT incubator to ensure that the set temperature and humidity ranges are maintained. If the temperature and humidity data deviate from the set ranges, it sends alarms and emergency messages to the user. The IoT-based chick incubation system developed in this paper is a low-cost model due to its reduced manufacturing cost, making it highly beneficial for self-sustaining poultry farms.

T800/AD6005계 복합재의 습기투과에 관한 연구

  • 박명규;류백능;최영보
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.35-36
    • /
    • 1997
  • 복합재는 강도가 높고 가볍기 때문에 최근 로켓의 연소관으로 널리 사용되고 있다. 그런데 이 복합재 로켓 연소관은 제조 후 대기 환경에 장기적으로 노출되어 있기 때문에 금속 연소관과는 달리 온도 또는 습도 등의 환경에 대한 영향을 고려해야 한다. 더구나 연소관은 내부에 추진제가 충전되어 있으므로 추진제의 기계적 특성이 습도에 민감함을 생각할 때 강도뿐만 아니라 습기의 투과도 또한 매우 중요한 고려 요소가 된다. 그러나 온/습도 변화에 따른 복합재 자체의 재료 특성 변화에 대한 연구는 많이 보고되었으나 습기의 투과 정도에 관한 연구는 자료가 미흡한 실정이다. 한편, 포화 함수율은 복합재에 따라서 차이가 있으나 T300/5208의 경우 문헌을 참조하면 20-$50^{\circ}C$에서 복합재 무게의 약 1.5% 정도이며 포화에 걸리는 시간은 약 100일 정도로 나타나 있다.본 연구에서는 수분이 복합재를 통하여 투과되는 정도를 고찰하기 위하여 $20^{\circ}C$,95%RH의 온/습도를 유지하는 수조를 제작하였고, 이 수조내에 보관한 복합재 연소관의 실린더 벽면으로 투과되는 습기를 측정하기 위하여 연소관 내에 습도 센서를 투입하여 상대습도를 직접 측정하였다. 복합재 연소관이 로켓에 사용될 때는 연소관 외부에 페인트로 피막 처리하고 연소관 내부에도 추진제와의 사이에 라이너가 접착되어 있어서 수분 침투 및 온도 등의 외부 환경조건에 견디기에 더 양호한 조건이나 본 연구에서는 복합재 자체의 특성을 고찰하기 위하여 섬유를 에폭시에 함침시켜 winding한 상태 그대로의 복합재 연소관 시료를 사용하였다. 습기의 투과는 내부에 라이너/인슐레이션이 피복되거나 또는 추진제가 충전된 경우 많은 감소효과를 보였다. 순수 복합재 연소관의 경우 수조에 넣고 평형에 도달한 후로부터 약 8개월의 습기 투과 상태를 볼대 벽면을 통하여 들어가는 water vapor flux는 $20^{\circ}C$,95%RH 에서 평균적으로 9.3163$\times$$10^{-8}$g/$m^2$sec로 나타났다. 이때 습기가 투과되는 연소관이 국지점을 평판으로 가정하고 Fick's law를 이용하여 구한 습기에 대한 복합재의 확산계수는 D=2.5$\times$$10^{-6}$$mm^2$sec였으며, 이는 다른 graphite/epixy 복합재의 확산계수와 유사한 값을 나타내고 있다. 또한 추진제가 충전된 연소관을 절단하여 밀폐한 후 95%RH 습도 조건에 보관함으로써 연소관 내부의 추진제 기계적 특성에 미치는 침투된 습기의 영향도 함께 고찰하였다. 추진제에 따라 차이는 있겠으나 추진제가 충전된 연소관은 순수 복합재 연소관에 비해 습기의 투과 정도가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.

  • PDF

Evaluation of sensor and control interface modules for greenhouse environment control (온실환경 제어를 위한 센서 및 제어 인터페이스 모듈의 성능평가)

  • Lee, Won-Jae;Duc, Ngo Viet;Sung, Nam-Seok;Seo, Young-Woo;Kim, Yong-Joo;Chung, Sun-Ok
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.137-137
    • /
    • 2017
  • 현재 상용화되어 있는 온실 환경제어시스템의 S/W 및 H/W는 서로 호환이 되지 않아 농민들이 원하는 맞춤형 복합 환경 제어시스템을 운영하는데 어려움이 있다. 따라서 본 연구는 다양한 제어알고리즘 및 장비를 적용시킬 수 있는 호환성이 향상된 온실 환경 제어인터페이스 모듈 성능평가를 목표로 한다. 센서 및 제어 인터페이스 모듈 성능평가를 위해 사용된 제어 시스템은 8 bit MCU가 적용된 전용 개발보드를 사용하였고, RS-232 통신 케이블을 사용하여 온실 환경 측정 데이터 값을 PC에서 수신할 수 있도록 하였다. 또한, 창개폐기, 환풍기를 사용하여 온실 내부 온/습도 환경조성을 하였다. 실험은 정오부터 제어장비를 작동시킨 후 1시간 간격으로 총 3시간 동안의 온실 내 온/습도의 변화량을 계측하였다. 3시간 중 1시간동안의 온/습도 값의 변화량을 계측한 결과 평균값은 각각 $33.21^{\circ}C$, 34.94%이었고 표준편차는 각각 $1.44^{\circ}C$, 2.74% 이었다. 제어 알고리즘은 단순한 ON/OFF 방법을 사용 하였고 총 2가지 제어장비를 사용하였으며 모두 정상 작동 하였다. 1시간동안 온실의 온도는 $30^{\circ}C{\sim}35^{\circ}C$사이를 유지하였으며, 습도는 30%~ 40% 사이로 최초 실험 목표였던 온실 내부의 온/습도 범위를 유지하였다. 이번 실험은 ON/OFF 방법의 제어 알고리즘을 사용하였지만 더욱 정밀한 온실 환경제어를 위하여 PID, 퍼지 제어 알고리즘을 추가하여 기상환경에 따른 제어범위를 더욱 세밀화 할 수 있도록 설계한다면 제어장비에 대한 효율성이 향상될 것이라 기대한다.

  • PDF