• Title/Summary/Keyword: 내부 냉각

Search Result 511, Processing Time 0.029 seconds

Design of the Heat Exchanger in Pool Water Management System of a Research Reactor and Estimation of the Pool Water Temperature Using CFD (전산유체해석을 이용한 연구용원자로 수조수관리계통 열교환기 설계 및 수조수 온도 예측)

  • Jeong, Namgyun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.45-51
    • /
    • 2016
  • The pool water management system, which is installed for purification of the coolant in the pools and the primary cooling system of a research reactor, removes the decay heat from the reactor core when the primary cooling system stops. It also removes the heat generated from the irradiated objects in the service pool and the spent fuels in the spent fuel storage pool to keep the temperature of the pools within a limited value. In this study, the heat exchanger of the pool water management system is designed by CFD method using a commercial code Flowmaster, and the temperature of the pools is estimated along the time to conclude the design and operation method of the pool water management system.

Subscale high altitude simulation test using solid propellant gas generator (고체추진제 가스발생기를 이용한 축소형 고공환경모사 시험)

  • Kim, Yong-Wook;Lee, Jung-Ho;Yu, Byung-Il;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.136-141
    • /
    • 2008
  • Cylindrical supersonic exhaust diffuser, which utilizes the momentum of high temperature gas exhausted from nozzle, provides simple methods for obtaining stable and low pressure around the propulsion system. Hot zone on which exhausted gas from nozzle exit impinges directly should be cooled to avoid melting of diffuser. This paper describes method and result of subscale high altitude simulation test with water cooling. Subscale gas generator with solid propellant was used for hot gas source and tap water for coolant.

  • PDF

Prediction of Temperature Distribution for Heat Treatment of 2.5% C-15% Cr Sleeve Casting Roll for Coke Biquette (2.5% C-15% Cr 성형탄 슬리이브 캐스팅로울의 열처리에 대한 온도 분포예측)

  • 하만영;윤영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.408-418
    • /
    • 1986
  • 본 연구에서는 표면은 단단하고 내면은 강인한 조직을 얻기위하여 대형 성형 탄 로울에 대하여 노에서의 급속가열 및 대기 상태에서의 자연냉각의 열처리가 수행 되어진다. 급속가열 및 냉각시 성형탄 로울 내부의 온도 분포 예측을 위하여 대류 및 복사 열전달 경계조건을 가지는 1차원 비정상 열전도 방정식이 유한 차분법을 사 용하여 해석되어졌다. 여기서 급속가열시 연소가스로 부터 기체복사에 의하여 성 형탄 로울의 바깥표면을 통하여 흡수되는 열량은

Design and Fabricate a Single Phase 1MVA Cable Transformer (단상 1MVA 케이블 변압기의 설계 및 제작)

  • Park, Jung-Ho;Heo, Woo-Heng;Cho, Ik-Choon;Jeong, Han-Jin;Kwon, Young-Ahn
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.71-73
    • /
    • 2006
  • 본 논문은 단상 1MVA 22.9kV/220V 케이블 변압기의 설계, 제작 및 시험 결과를 서술한다. 케이블 변압기는 유입변압기의 폭발위험성과 환경오염 가능성이 없으므로, 인구밀집지역, 지하장소등 설치장소의 제한이 없는 장점이 있다. 제작된 케이블 변압기는 22.9kV급의 XLPE 케이블 전선을 사용하여 1차 권선을 제작하였으며, 2차측 권선은 내 단락시 특성이 우수한 몰드 권선 형태로 제작하였다. 사용된 XLPE 케이블은 도체-내부반도전층-XLPE-외부반도전층으로 구성되어 있으며, 외부반도전층은 접지된 구조이다. 철심은 단상 3각 구조로써 방향성 규소강판을 사용하였으며, 냉각방식은 공기 자연냉각방식이다. 제작된 변압기의 신뢰성을 확보하기 위하여, 특성시험과 절연시험을 실시하였다.

  • PDF

Nonlinear spectroscopy of cold rubidium atoms in three-level $\Lambda$-type systems (냉각된 루비듐 원자를 이용한 3준위 $\Lambda$-구조 원자계에서의 비선형 분광학)

  • Park, Sung-Jong;Cho, Hyuk;Park, Jong-Dae;Kwon, Taek-Yong;Lee, Ho-Sung
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.22-23
    • /
    • 2002
  • 최근 레이저 쿨링 및 포획 기술은 다양한 과학적 분야에 응용되고 있다. 포획 원자는 고밀도 매질이며 100 $\mu$ K 이하의 온도를 갖기 때문에 레이저 분광학 분야에서 큰 관심을 갖게 되었다. 포획된 원자에 대한 분광학적 특성 조사는 원자의 운동학적 상태뿐만 아니라 포획 원자의 내부 상태에 대한 정보를 제공해 주기 때문에 포획 및 냉각 실험에 필수라고 할 수 있다. (중략)

  • PDF

A Design of Engine Exhaust Ejector for Smart UAV (스마트무인기의 엔진 배기이젝터 설계에 관한 연구)

  • Lee, Chang-Ho;Kim, Jai-Moo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.403-406
    • /
    • 2006
  • An ejector is designed for the purpose of engine bay cooling. The primary flow of the ejector is the exhaust gas of the PW206C turboshaft engine. The mass flow of secondary flow is calculated by using the approximate analytic equation. For the purpose of verification of approximate analytic method, comparison is made with the results of Navier-Stokes turbulent flow solution. According to the results of CFD, the mixing of two flows is incomplete due to the short length of mixing duct.

  • PDF

Analysis of Thermal Effect by Coolant Plate Number in High-Temperature Polymer Electrolyte Membrane Fuel Cell Stack (고온형 고분자 전해질 연료전지 스택 내부의 냉각판 수가 스택에 미치는 열 영향성의 수치적 연구)

  • Choi, Byung Wook;Ju, Hyun Chul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.2
    • /
    • pp.127-135
    • /
    • 2015
  • High-Temperautre Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) with phosphoric acid-doped polybenzimidazole (PBI) membrane has high power density because of high operating temperature from 100 to $200^{\circ}C$. In fuel cell stack, heat is generated by electrochemical reaction and high operating temperature makes a lot of heat. This heat is caouse of durability and performance decrease about stack. For these reasons, heat management is important in HT-PEMFC. So, we developed HT-PEMFC model and study heat flow in HT-PEMFC stack. In this study, we placed coolant plate number per cell number ratio as variable and analysed heat flow distribution in stack.

Temperature Rise of the MV Class Transformer Filled with a Vegetable Fluid (식물성 절연유를 사용한 배전용 변압기의 온도변화 특성)

  • Lee, Byung-Sung;Park, Chul-Bae;Song, Il-Keun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2060-2061
    • /
    • 2008
  • 식물성 절연유는 기존 광유계 절연유에 비해 친환경성과 안전성이 부각되어 전력용 변압기에 사용을 검토하고 있다. 우수한 생분해성 및 높은 인화점, 발화점을 갖는 반면, 점도가 높아 냉각 효과가 줄어드는 단점이 있다. 변압기 절연유의 역할이 절연과 냉각이므로 광유에 비해 약 3배 정도 높은 점도를 갖는 식물유를 사용할 경우 변압기 권선 내부 온도 상승을 검토하여야 한다. 본 연구에서는 배전급에 사용되는 변압기에 광유 대체로 식물유를 사용하였을 때 권선 및 유온도 상승을 측정하였다. 변압기 권선 구조 설계에 있어서 정확한 권선온도 상승 값을 활용하여야 적정 수명 유지가 가능해 진다.

  • PDF

Experimental Study on the Freezing Conditions in a Ice-making Tube Using Flowing Subcooled Water (유동과 냉각수 이용 제빙관의 동결조건에 5관한 실험적 연구)

  • 박영하;현명택;이동원
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.178-183
    • /
    • 2000
  • 본 연구에서는 유동과 냉각수를 이용하는 아이슬러리 제조관정을 관찰하고, 이 시스템의 가장 큰 문제점인 관내동결 특성을 파악하였다. 시험수로는 수도수(city water)를 이용하였다. 시스템을 순환하는 시험수가 제빙관내에서 $0^{\circ}C$ 이하의 과냉각 조건이 형성되어 제빙관을 빠져 나오면서 축냉조에 설치된 충격판상에서 과냉각 해소가 일어났다. 이때 유동과냉각수는 내부에너지를 방출하면서 그 일부가 얼음 입자로 상변화되었고, 나머지는 실험장치를 계속순환하였다. 제빙관에서 시험수와 브라인의 열교환 방식을 대향류와 평행류 두 조건에서 시험수의 과냉각도는 Reynolds 수가 증가함에 따라 감소하는 경향을 보였고, 이들 결과 값으로부터 각각의 관계식을 유도하였다. 또한 브라인의 냉각속도가 0.29~0.53[$^{\circ}C$/min] 범위에서 시험수의 과냉각도는 브라인 냉각속도에 종속되지 않았다.

  • PDF

소멸처리로 중성자원 고체표적물의 온도상승에 관한 연구

  • 조재선;허병길;정창현;송태영;박원석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.609-614
    • /
    • 1998
  • 고준위 방사성 폐기물 처분과 관련이 있는 가속기구동 소멸처리로는 미임계로이기 때문에 별도의 중성자원이 필요하다. 가속기에서 나오는 양성자를 받아 중성자를 발생시키는 중성자원으로 사용될 표적물로서 거론되는 방안중에 하나인 고체표적시스템에 대한 열전달 예비계산을 수행하였다. 고체표적물의 물질은 텅스텐을 대상으로 하였으며 표적시스템은 원통형구조를 가정하였다. 양성자 조사에 의한 텅스텐 물질의 핵파쇄반응으로 인한 내부발열을 모사하여 표적물내에서의 온도상승속도와 온도분포를 조사하였다. 계산결과 별도의 표적물에 대한 냉각시스템이 없는 상황에서 30∼37초만에 국부적으로 텅스텐의 온도가 녹는점 이상으로 상승하는 결과를 보였다. 따라서 고체표적물 시스템을 소멸처리로에서 사용하기 위해서는 표적물을 냉각시키기 위한 다각도의 방안이 모색되어야 한다.

  • PDF