• Title/Summary/Keyword: 내부피폭선량평가

Search Result 74, Processing Time 0.06 seconds

Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon (한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출)

  • Park, Sang-Hyun;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • MIRD-type Korean adult male phantom, 'KMIRD' was constructed to calculate Korean-specific dosimetric quantities for radiation protection consideration. The external shape of KMIRD was based on national physical standard data of Korean. KMIRD has thicket trunk than MIRD5 and arm models divided from trunk. The height and weight of the KMIRD are 171 cm and 63.8 kg. ICRP23 data were referred to constitute organs and tissues of KMIRD. However nine organs were constructed based on Korean reference data provided by Radiation Health Research Institute. In the present study, the MCNPX2.3 Monte Carlo transport code was combined with KMIRD to calculate dose conversion coefficients for photon in the energy range from 0.05 to 10 MeV. The simulated irradiation geometries are broad parallel photon beams in AP, PA, LLAT and RLAT direction. Absorbed dose conversion coefficients were compared with data calculated with MIRD5, MIRD-type phantom based on ICRP23 reference man. In some organs, the discrepancies between two phantoms amount up to nearly 30%. The effective doses conversion coefficients of KMIRD are lower than those of MIRD5. The dose discrepancies between two MIRD-type phantoms ate because of physical differences between Korean and Western, also geometric differences between two phantoms. KMIRD should be revised using the full set of Korean reference data of all organs. The developed MIRD-type Korean adult male phantom can be applied to dose assessment of internal exposure.

A Preliminary Study on the Evaluation of Internal Exposure Effect by Radioactive Aerosol Generated During Decommissioning of NPPs by Using BiDAS (BiDAS를 적용한 원전 해체 공정 시 발생되는 방사성 에어로졸의 내부피폭 영향평가 사전 연구)

  • Song, Jong Soon;Lee, Hak Yun;Kim, Sun Il
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.473-478
    • /
    • 2018
  • Radioactive aerosol generated in cutting and melting work during the NPP decommissioning process can cause internal exposure to body through workers' breath. Thus, it is necessary to assess worker internal exposure due to the radioactive aerosol during decommissioning. The actually measured value of the working environment is needed for accurate assessment of internal exposure, but if it is difficult to actually measure that value, the internal exposure dose can be estimated through recommended values such as the fraction of amount of intake and the size of particles suggested by the International Committee on Radiological Protection (ICRP). As for the selection of particle size, this study applied a value of $5{\mu}m$, which is the size of particles considering the worker recommended by the ICRP. As for the amount of generation, the amount of intake was estimated using data on the mass of aerosol generated in a melting facility at a site in Kozloduy, Bulgaria. In addition, using these data, this study calculated the level of radioactivity in the worker's body and stool and conducted an assessment of internal exposure using the BiDAS computer code. The internal exposure dose of Type M was 0.0341 mSv, that of Type S was 0.0909 mSv. The two types of absorption showed levels that were 0.17% and 0.45% of the domestic annual dose limit, respectively.

Evaluation of Dose Enhancement by Gold Nanoparticles using Mathematical Head Phantom (금 나노입자를 활용한 두부 모의피폭체에서의 선량증가 효과 평가)

  • Hwang, Chulhwan;Park, Eun-Tae;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.477-483
    • /
    • 2016
  • The effect of dose enhancement was evaluated using Snyder head phantom, dependence on size of gold nanoparticle and material concentration in megavoltage X, ${\gamma}$-ray. Monte Carlo simulation using MCNPX was used for 4, 6, 10, 15 MV and Co-60 ${\gamma}$-ray. Described the tumor in Snyder head phantom, gold nanoparticle of 25, 75, 125nm diameter was inserted inside tumor. Concentration of dose enhancement material was used for 5, 15, 25 mg/g and dose enhancement factor was calculated on the basis of the no dose enhancement material. The lower incident energy and the higher concentration of material were that high dose enhancement factor is indicated. The size of gold nanoparticle had relatively high dependence on lower incident energy and higher concentration of material. It will increase dose inside the tumor, and be additional effect of use of gold nanoparticles in radiation therapy.

Analysis of Exposure Pathways and the Relative Importance of Radionuclides to Radiation Exposure in the Case of a Severe Accident of a Nuclear Power Plant (원전 중대사고시 피폭경로 및 핵종의 방사선 피폭에 대한 상대적 중요도 해석)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.209-221
    • /
    • 1994
  • In the case of a severe accident of a nuclear power plant, the whole body dose and the relative importance of the radionuclides during the lifetime of an exposed person were estimated for each exposure pathway with distances from the release point. The external exposure pathways due to immersion of radioactive cloud and deposition of radioactive materials on the ground, and the internal exposure pathways due to inhalation and ingestion of contaminated foodstuffs were considered. The effects due to the ingestion of contaminated foodstuffs were estimated considering the variation of radioactive concentration in the foodstuffs according to deposition time and elapsed time after deposition using a dynamic ingestion pathway model applicable to Korean environment, named 'KORFOOD'. As the results up to 80 km from the release point, the effects due to ingestion of contaminated foodstuffs showed the highest contribution to total exposure dose. The contribution of I isotopes was the highest in the case of the external dose due to immersion of radioactive cloud and internal dose due to inhalation. The contribution of Cs isotopes was highest in the case of the external dose due to deposition of radioactive materials on the ground. In the case of the internal dose due to ingestion of contaminated foodstuffs, Cs deposition in summer and Sr deposition in winter, respectively, were the most dominant radionuclide to whole body.

  • PDF

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Calculation of Internal Exposure Dose in Korean Man Resulting from Single and Chronic Intake of Tritium (트리튬($^{3}H$)의 단일(單一) 및 만성섭취(晩性攝取)에 대한 한국인(韓國人)의 내부피복(內部被曝) 선량(線量) 계산(計算))

  • Kim, Jang-Lyul;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.2
    • /
    • pp.8-14
    • /
    • 1983
  • The doses to Korean adult by a single and chronic intake of tritiated water are determined using a three compartment model, which describes the retention of tritium radionuclide in body water and in bound organic form in the body. The results show that the total dose of a single intake, using retention half-time for the three-compartment of 9, 30, and 450 days, is 17.64 mrads ($176.4{\mu}Gy$) per 1mCi/kg ($3.7{\times}10^7Bq/kg$) intake, 97% of which is due to tritium in body water and 3% to bound tritium in tissue. In the chronic intake of 1mCi/day($3.7{\times}10^7Bq/day$) tritiated water, the total dose is 85.5 mrad/day(0.855mGy/day). Furthermore, in this study (MPC) a and (MPC)w values of tritium for Korean man are calculated by using the modified formula originated from ICRP Publication-2. From the results, we found that the (MPC) a, w values of ICRP underestimated approximately 50%, the (MPC)a, w values of Korean man must be elevated as high as approximately 50% than that of ICRP.

  • PDF

A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter (전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Whole body counters (WBCs) are used to monitor radiation workers for internal contamination of radionuclides at domestic nuclear power plants (NPPs). A WBC is a scintillation detector using sodium iodide (NaI) and provides the identification of inhaled radionuclide and the measurement of its internal radioactivity in a short time. However, it is often possible to estimate external contamination as internal contamination due to radionuclides attached to the skin of radiation workers and this leads to an excessively conservative estimation of radioactive contamination. In this study, several experiments using a WBC and the Korean humanoid phantom were performed to suggest the more systematic method of discrimination between external and internal contamination. Furthermore, a WBC geometry experiment was conducted to suggest the optimal WBC geometry in consideration of deposited areas inside the body for dominant radionuclides at NPPs. The procedure of measurement and estimation of internal radioactivity for radiation workers at NPPs was improved on the basis of experimental results. Thus, it is expected to prevent from estimating internal exposure dose conservatively owing to the application of accurate whole body counting program to NPPs.