• Title/Summary/Keyword: 내력벽 구조

Search Result 69, Processing Time 0.034 seconds

Behavior of Coupling Shear Wall with New Openings (개구부 신설에 따른 병렬 전단벽의 거동특성)

  • Choi, Hyun-Ki;Choi, Youn-Cheul;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.152-160
    • /
    • 2008
  • Since wall system apartment used the shear wall as main lateral resistance member, installation of openings which causing section loss of walls may cause significant problem to structure. Also, there are few studies for inducing coupling beam or slabs which are occurred by installing openings. Therefore, this study planned isolated 2-story shear walls which are reduced three half-scale specimen to find out walls behavior characteristic. The test results showed that strength reduction caused by loss of effective section of walls and different result of stiffness and energy dissipation regarding to the coupling beam and coupling slabs.

Pre-weakening Analysis for the Explosive Demolition on the Structural System Consisted of Load Bearing Wall (내력벽으로 구성된 구조물의 발파해체를 위한 사전취약화 해석)

  • Choi, Hoon;Hong, Soon-Joong;Mun, Byung-Hwa;Kim, Hyo-Jin;Yoon, Soon-Jong
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.76-85
    • /
    • 2010
  • In this paper, we present the result of an analytical investigation concerning the demolition range for the pre-weakening of load-bearing wall in explosive demolition. Pre-weakening of load-bearing wall is usually conducted based on field experience because reliable specifications or guidelines for the design of pre-weakening have not yet been established in Korea. This study is one of the efforts to develop such a reliable specification or guideline for the pre-weakening process. Hence, the focus of the study is on the estimation of pre-weakening range of load-bearing wall. For the purpose, a finite element analysis (FE analysis) was conducted, and a pre-weakening range of load-bearing wall was suggested based on the analysis result.

Behavior of Three Story Bearing Wall Structure under Lateral toad Reversals (반복 수평하중을 받는 3층 철근콘크리트 내력벽 아파트 구조물의 거동 특성)

  • Chang Kuk-Kwan;Oh Young-Hun;Kim Ki-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.627-634
    • /
    • 2004
  • The purpose of this study is to investigate seismic performance of a bearing wall system for apartment buildings. An 1/3 scale three-story specimen was constructed and tested under cyclic lateral loads. The specimen was consisted of pierced walls and coupling elements as well as floor slabs. The bearing wall system is considered to have a adequate deformation capacity up to $2.0\%$ of roof drift ratio, and the experimental results showed the ductile load-deformation characteristics even though some walls were failed in shear Nonlinear analysis was peformed to compare the load-deformation curve obtained from the experimental program. The result of nonlinear analysis could be useful to predict the actual behavior characteristics of the bearing wall system subjected to lateral loads.

An Experimental Study on Shear Friction Behavior of RC Slab and SC(Steel Plate Concrete) Wall Structure with Connection Joint (RC 슬래브와 SC 벽 접합부의 전단마찰 거동에 관한 실험연구)

  • Lee, Kyung Jin;Hwang, Kyeong Min;Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.6
    • /
    • pp.623-634
    • /
    • 2013
  • In this study, the structure behavior of RC slab and SC shear wall connection was investigated. Also experimental study was performed to evaluate the factor of safety of demand shear connection strength in KEPIC SNG Standard. As a result, shear friction strength of connection was known about 300kN and shear strength of rebar increased according to the displacement increase. With the installment of the lower rebars, 40% shear strength increased compared to the non-rebar specimen.

Structural Behaviour of the Wing Wall with Columns (날개벽이 있는 기둥의 구조적 거동 특성)

  • Kang, Young-Woong;Yang, Won-Jik;Kang, Dae-Eon;Yi, Waon-Ho;Song, Dong-Yup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.73-74
    • /
    • 2009
  • Current buildings have complex shaped walls where the wing wall system is a popular option. When the wing wall is attached to a column, or a short span is produced due to the wing wall system, the system affects the behaviour of the column such as by increasing the strength and decreasing the ductility of the members. Calculations for internal shear force and internal bending moment of the vertical members are considered an important matter in design, but currently Korea does not have studies on the effects of the wing wall on the columns.

  • PDF

Seismic Capacity according to Structural System of High-rise Apartment (고층 아파트 구조시스템에 따른 내진성능 분석)

  • Lee, Minhee;Cho, So-Hoon;Kim, Jong-Ho;Kim, Hyung-Do
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.3
    • /
    • pp.149-154
    • /
    • 2019
  • The structural system of domestic high-rise apartments can be divided into two parts; the core wall system, which is composed of walls concentrated in the center and the shear wall system, which comprises a great number of walls distributed in the plan. In order to analyze the lateral behavior of each system, buildings with typical domestic high-rise apartment plans were selected and nonlinear static analysis was performed to investigate the their collapse mechanism. From the force-displacement relation derived from nonlinear static analysis, response modification factor was evaluated by calculating the overstrengh and ductility factor, which are important in the seismic response. The ductility of core wall system is small, but as it is governed by wind load, its overstrength is greatly estimated, and its response modification factor is calculated by the overstrengh factor. Due to a large number of walls, shear wall system has a large ductility, making the response modification factor considerably large.

Fragility Analysis of RC Moment Resisting Framewith Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Choi, Byeong-Tae;Kim, Min-Gyun;Lee, Ui-Hyun;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.442-445
    • /
    • 2009
  • 지진에 대한 건축물의 확률적 성능평가에 대해서는 지진하중에 대한 건축물의 손상확률 또는 파괴확률을 나타내는 지진취약도 함수를 작성하여 대상 건축물에 대한 지진위험도를 평가하는 방법을 이용하고 있으며 이에 대한 많은 연구가 이루어지고 있다. 본 연구에서는 지진하중과 구조물 재료특성의 불확실성을 고려하고 대상 건축물의 지진취약도 해석을 통하여 비내력벽의 유무에 따른 건축물의 지진거동 및 내진성능을 평가하였다. 비내력벽을 보편화된 모형화 방법인 등가의 대각 압축 스트럿으로 고려하여 비내력벽의 유무에 따른 저층 철근콘크리트 건축물을 모형화하였으며 지진하중의 강도는 유효최대지반가속도를 이용하여 각 건축물에 대하여 지진취약도를 작성하였다. 취약도해석 결과로 연약층을 가지고 있는 건축물의 경우는 손상확률이 골조만 있는 경우보다 크며 동일한 해석모델의 경우에도 해석방법에 따라서 취약도 곡선의 형태가 다름을 알 수 있었다.

  • PDF

Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.355-362
    • /
    • 2009
  • Many of residential buildings, which have pilotis in lower stories to meet the architectural needs, are recently constructed in Korea. Usually, infill walls located in the upper stories of these buildings may cause a soft first story, which is very weak from the earthquake resistance. In the design of the buildings, the infill walls of upper stories are usually considered as non-structural elements and thus they are not included in the analytical model. However, the infill walls may affect the seismic behavior of the residential buildings. Therefore, the differences in seismic behaviors of RC buildings with and without masonry infill walls are required to be investigated. In this study, seismic fragility analyses were performed for masonry infilled low-rise RC moment-resisting frames. And seismic behaviors of RC moment-resisting frame with/without masonry infill walls were evaluated. Two types of structural system with the same frame and different allocation of infill walls are used to evaluate the influence of masonry infill walls on seismic behavior of RC moment-resisting frames. The infill walls were modeled as bi-equivalent diagonal struts. The fragility analyses show that the seismic performance of RC moment-resisting frames with soft story is below the desirable building seismic performance level recommended by current seismic codes, indicating high vulnerability of RC moment-resisting frames with soft story.