Evaluation on the Durability of Ductile Fiber Reinforced Cementitious Composites(DFRCC) (고인성 섬유보강 시멘트 복합체의 내구성 평가)

  • Ryu, Gum-Sung;Koh, Kyung-Taek;Park, Jung-Jun;Kang, Su-Tae;Kang, Hyun-Jin;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.535-536
    • /
    • 2009
  • This study was carry out to evaluate the durability of Ductile Fiber Reinforced Cementitious Composites(DFRCC) according to W/B ratio(30, 40, 50%). The results is showing that DFRCC outstandingly improved to compare to plain concrete for the resistance of chloride ion penetration and rapid freezing and thawing

  • PDF

Production Process Development and Prototype Evaluation for Roller Tappet Housing of Valvetrain (밸브트레인용 롤러태핏 하우징의 제작 공정 개발 및 시제품 평가)

  • Gwak, Eun-Jo;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.223-229
    • /
    • 2016
  • In this study, a cold forging process was developed for the roller tappet housing of an engine valvetrain system. A tappet sample was manufactured and subjected to an endurance test. The material properties were obtained from a compression test, and forging analysis was carried out to design a forging process using a commercial program, Deform-3D. The forging process was set up based on the analysis results, and a die set and sample tappet housing were manufactured. To evaluate the sample, the dimensional accuracy, surface roughness, parallelism, and concentricity were measured and confirmed. To evaluate the actuation and durability, a special test rig was developed to simulate the valvetrain system of the engine. An actuation test was performed based on the idle speed of a general diesel engine, and an endurance test was done based on the maximum speed. The results show minor wear of 0.002 mm. The developed test rig will be used to evaluate the actuation and durability of other valvetrain parts.

A Estimation of Thermal Fatigue Performance in Three-way Catalyst (삼원 촉매의 열적 내구 성능 평가)

  • Lee, Sung Riong;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • This study examines thermal safety on three-way catalyst that dominates 70% among whole exhaust gas purification device in 2003. Three-way catalyst maintains high temperature in interior domain but maintains low temperature on outside surface. Therefore this device shows tensile stress on outside surface. Temperature distribution of three-way catalyst was acquired by thermal flow analysis for predicted thermal flow parameter. Thermal stress analysis for three-way catalysis was performed based on this temperature distribution. Thermal safety of three-way catalyst was estimated by strength reduction factor and failure probability.

A Study on Assessment of Fatigue Durability for Composite Torque Link of Landing Gear (착륙장치 복합재 토크링크 피로내구성 평가에 대한 연구)

  • Kwon, Jung-Ho;Kang, Dae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.537-546
    • /
    • 2010
  • This research work contributed to a study for the procedure and methodology to assess the fatigue durability for a composite torque link of helicopter landing gear, which was newly developed and fabricated by the resin transfer moulding technique to interchange with metal component. The simulated load spectrum anticipated to be applied to the torque link during its operation life was generated using an advanced method of probabilistic random process, and the fatigue durability was evaluated by the strength degradation approach on the basis of material test data. The full scale fatigue test was also performed and compared with the analysis results.

The Research for the Establishment of Test Method of Durability on Intumescent Coating System (내화도료 내구성 평가 방법 설정에 관한 연구)

  • Choi, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-47
    • /
    • 2009
  • Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. So it is necessary to understand changes of the durability and the fire resistance performance of intumescent coating system over a time elapse and to reflect such change properly into the building design and construction. This research is performed to present the test method of durability and the maintenance of intumescent coating system through theoretical investigation of the test method of durability and the guide of maintenance & management of intumescent coating system of several countries, including the Britain, United States, Japan.

Evaluation of Durability and Self-clearing in Concrete Impregnated with Photocatalyst-colloidal Silica (광촉매-분산 실리카 함침 콘크리트의 내구성 및 정화성능 평가)

  • Kim, Hyeok-Jung;Kim, Young-Kee;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.47-54
    • /
    • 2018
  • Concrete undergoes various deterioration on surface. Impregnant with silicate is usually applied to concrete surface and forms insoluble hydrates, which can provide many engineering advantages. In the work, concrete impregnated with colloidal silicate is used for durability enhancement in surface and self-clearing performance is evaluated with photocatalyst-$TiO_2$ spraying. For the work, various tests are performed both for strength evaluation and durability evaluation such as absorption ratio, drying shrinkage, chloride penetration, sulfate resistance, and freezing/ thawing action. Furthermore, removal and self-clearing performance are evaluated with Acetaldehyde decomposition and Methylene blue decolorization. Through silicate impregnation and photocatalyst spraying, the impregnated concrete can have not only durability enhance but also self-clearing performance.

Reliability based durability assessment of marine concrete structures (해양 콘크리트 구조물의 신뢰성 기반한 내구성 평가)

  • Song, Ha-Won;Lim, Dong-Woo;Pack, Seung-Woo;Lee, Chang-Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.497-500
    • /
    • 2008
  • In order to prevent deterioration of reinforced concrete structures exposed to marine environment, performance based durability design than the design by conventional deemed-to-satisfy rule should be concerned. For example, even though chloride threshold level, which is a major parameter for durability design, is defined as a 1.2 $kg/m^3$ in the Korean concrete specification, it shows that the chloride threshold level leads to over design in its real application so that realistic value should be determined for the performance design. In this paper, not only the probabilistic properties of chloride threshold level obtained from published data are taken into account, but also the experimental results of the probabilistic properties using surface chloride content, diffusion coefficient, cover depth are considered in the assessment utilizing the concept of performance based durability design. In computation, the Monte Carlo Simulation (MCS) is used to perform an assessment due to chloride attack for a target submerged tunnel box. This study found that the specification on current chloride threshold level should be modified for more rational and accurate assessment and design.

  • PDF

Durability Performance Evaluation of PolyUrea for Seismic Retrofitting of RC Structures (구조물 내진 보강용 폴리우레아의 내구 성능 평가)

  • Cho, Chul-Min;Kim, Jang Jay Ho;Lee, Doo-Sung;Kim, Tae-Kyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • An experimental study is needed a reinforcing method for seismic load to apply for RC structures because a lot of earthquakes have frequently happened in the world and those also collapsed infrastructures or damaged human lives. The reinforcing effect of PolyUrea (PU) appeared to be excellent under blast and impact about RC structures. In this study, Stiff Type PolyUrea (STPU) had developed by manipulating the ratio of the components of prepolymer and hardener of PU. And the durability performance evaluation of STPU for deterioration and chemical resistance has been performed. Acid environmental exposure test and ultraviolet (UV) exposure test have been performed as the durability performance evaluation for STPU. Concrete carbonation exposure test and freezing and thawing test for concrete coated with STPU have been performed. The experimental result showed that STPU has high resisting capacity and durability in all tests. Therefore, STPU would be used as seismic reinforcement materials.

Assessment of Durability of Stone Monument Using Specimens from Old Stone Quarry (고대 채석장 부지의 시료를 이용한 석조문화재 내구성 평가)

  • Park, Hyeong Dong;Shin, Gi Hye;Aboushook, M.
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.19-24
    • /
    • 2001
  • This study mainly reports preliminary results from site investigation of the Great Pyramids and Sphinx in Egypt and sampling works where conducted in the same limestone beds in Mokattam quarry in Cairo. Analyses of composition of samples showed similar result to those of limestone in Giza and thus such samples can be easily used for further experimental work without disturbing real monuments. Future work will be concentrated on the change of engineering properties of samples before and after artificial weathering and the change of digital image acquired from the colored surface of monuments.

  • PDF

Long-Term Degradation Mechanism of GFRP Dowel Bar for Jointed Concrete Pavement under Repeated Freezing-Thawing (동결융해 반복을 받는 콘크리트 포장용 GFRP 다웰바의 장기성능저하 메커니즘)

  • Won, Jong Pil;Jang, Chang Il;Park, Chan-Gi;Lee, Sang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.325-330
    • /
    • 2008
  • This study carried out the repeated freezing-thawing test in order to understand the long-term degradation mechanism of GFRP dowel bars. The mechanical property measured by shear test. In addition, analyzes repeated freezing-thawing degradation mechanism of GFRP dowel bars by observe the microstructure through Scanning Electron Microscope (SEM) and Gas Physisorption techniques. As the result of test, it was found that the mechanical property didn't decreased as the exposure time to water and repeated freezing-thawing environment. It shows clearly observed microstructure investigations.