• Title/Summary/Keyword: 난방 시간

Search Result 138, Processing Time 0.027 seconds

Indoor Air Temperature Distribution in a Floor Heating Space with PCM Panels (잠열저장패널이용 바닥난방공간의 실내온도분포에 관한 연구)

  • Cho, Soo;Sohn, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 1992
  • The purposes of the present study are to investigate the characteristics of heat storage and emission of the PCM($CalCl_2{\cdot}6H_2O$) panel, and to analyze the distribution of indoor air temperature in a floor heating space with PCM panels for the heating system. Two identical unit test cells sized $1.8m^W{\times}1.8m^L{\times}1.8m^H$ were built and installed with specially designed aluminium Ondol-panels. It held 1.2kg of calcium chloride hexahydrate(CCH). It was found that PCM panels could reduce the indoor air temperature fluctuations and maintain the phase changing temperature for considerably long duration, $2{\sim}3$ times longer in heating hour over no-CCH one. When the elapsed time was 6 hours, the average temperature difference between PCM panel and Ondol panel was $7.7^{\circ}C$.

  • PDF

A Study On heating load analysis and demand side management on winter peak period (동계피크시 계약종별 난방부하분석 및 수요관리 대응방안 연구)

  • Yun, Young-Bum;Kang, Dong-Pil;Lee, Kyung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.588-589
    • /
    • 2011
  • `10. 1. 13일 한파지속에 따른 16년 만에 동계피크가 발생 하였으며, '11. 1. 17일 73,137MW로 2년 년속 동계피크 경신으로 우리나라도 이젠 동계피크 발생국가에 해당된다고 볼 수 있다. 이는 경기회복에 따른 산업용전력의 증가가 동계피크 발생을 견인하였지만 타 에너지원에 비해 전기요금이 저렴하기 때문에 난방연료원이 가스나 가름에서 전기로 지속적으로 전환된 것이 가장 큰 원인이라고 보여 진다. 효과적인 전력수요관리를 위해서는 계약종별별로 부하량과 난방부하량을 측정해서 분석하는 것이 무엇보다 중요하다 하겠다. 그렇지만 실시간으로 계약종별로 부하량 자료를 얻을 수 있는 것은 현재 고압고객의 AMR계량시스템자료가 있으나 이는 고압전체의 85% 대 수준의 자료를 읽어올 뿐 전제 부하를 대변할 수 없으므로 발전단 부하를 계약종별로 적절하게 안분하는 것이 필요하다고 볼 수 있다. 8760시간대별 부하분석을 위해서는 발전단 부하와 배전단부하를 근간으로 고압고객의 원격자동검침(AMR) 자료를 활용하여 최대피크기여도를 분석하여 부하분석을 수행하였다.

  • PDF

A Study of the Relations between the Furnace and Housing structure - Focusing on The Honam Area - (원시$\cdot$고대의 노시설과 주거구조와의 상관성 연구 - 호남지역을 중심으로 -)

  • Lee Min-seok
    • KOMUNHWA
    • /
    • no.62
    • /
    • pp.29-58
    • /
    • 2003
  • It has been well known that the function of the furnace is to cook, to heat, and to light. Especially, it is easy to grasp relations between the furnace forms and the dwelling structure because the furnace was a part of the most important housing culture.

  • PDF

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

보일러의 보전

  • 한국온돌난방시공협회
    • 보일러설비
    • /
    • s.78
    • /
    • pp.64-67
    • /
    • 2000
  • 장마가 막 지나가고 실내의 눅눅한 습기를 없애려고 보일러를 잠시 킨 후 보일러는 긴 휴지기에 들어 간다. 24시간 계절과 상관없이 오랫동안 가동되는 보일러를 사용하게 되면 여러 가지 고장이나 손상이 생기기 쉽다. 이런 것들을 미연방지하거나 또는 고장이나 손상이 확대 되기전에 신속히 보수하여 항상 보일러를 정상상태로 유지시키는 것을 보전이라고 한다. 보일러의 보전방법에는 여러 가지가 있지만 여기서는 보일러의 정비 및 휴지에 관해 설명하겠다.

  • PDF

Development of Automatic Control System for Midnight Electric Ondol (축열식전기온돌 공급시간 자동제어시스템 개발)

  • 박석인;정봉만;유승원
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.29-33
    • /
    • 2002
  • 최근 전력부하 평준화를 통한 경영효율 증진을 위하여 난방 및 급탕에 사용되는 심야전력기기 보급을 정책적으로 적극 추진하고 있다. 현재 한전에서는 심야전력공급개시시간인 22:00부터 익일 08:00까지 심야전력을 공급하고 있으나 전국의 모든 심야전력기기가 22:00에 동시에 가동됨에 따라 한시간이 경과한 23:00에 심야전력 부하가 최대에 이르고 있으며, 이에 따라 심야전력기기에 의한 전력피크 발생 우려가 현실로 나타나고 있다.(중략)

  • PDF

Study on the Temperature Distribution of Cabin under Various Car Heating Modes (난방기 출력에 따른 철도차량 객실 내부 온도 분포 분석)

  • Cho, Youngmin;Yoon, Young-Kwan;Park, Duck-Shin;Kim, Tae-Wook;Kwon, Soon-Bark;Jung, Woo-Sung;Kim, Hee-Man
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.558-565
    • /
    • 2012
  • Abnormal climate or weather is more frequently reported nowadays due to the global climate change. Especially, extremely low temperature in winter season may cause bad thermal discomfort of passengers. In this study, the effect of car heating modes on cabin temperature change and distribution was studied by using a real-scale environmental chamber for passenger cabin. It was found that the cabin temperature rose quickly at the initial stage of heating system operation, but it stopped increasing after certain point. And, temperature was higher when the height from the floor was higher. Based on the obtained result, the way to minimize the decrease of passengers' thermal comfort was suggested.

태양열 구동 흡수식 냉방 시스템 실증

  • Gwak, Hui-Yeol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.353-362
    • /
    • 2005
  • 태양열시스템은 하절기에 급탕과 난방 부하가 적거나, 거의 없어 시스템의 과열 문제가 야기 될 수 있다. 이를 해결하는 방안 중에 하나로 흡수식 냉방시스템을 이용하여 하절기 잉여열원을 활용하여 냉방하는 방법이 대두되고 있다. 태양열 냉방시스템은 전기에너지를 대체하는 효과 뿐 아니라 태양열 연간 이용 효율 극대화에도 크게 기여 할 수 있다. 본 고에서는 국내 기술로 최초로 개발 실용화된 중온용 단일 진공관형 태양열 집열기와 1중 효용 흡수식 냉방기를 이용하여 실증연구를 계획하였다. 태양열 냉방 실증을 위하여 단일 진공관형 태양열 집열기 집열면적 200m2, 축열조(태양열, 급탕, 냉수), 10RT급 냉방기, 냉각탑, 보조 보일러, 원격 제어 및 모니터링 등이 계획 되었다. 실증시험 중간 결과 태양열 냉방시스템은 하절기 맑은 날 하루 동안 약 5 - 6시간 안정적으로 가동 되었으며, 앞으로 온수급탕, 난방 시험을 거쳐 시스템 성능 및 경제성 평가를 통하여 유용성, 안정성 및 신뢰성이 검증 될 계획이다.

  • PDF

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System (바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.